Understanding Variation Among Medical Device Reporting Sources: A Study of the MAUDE Database.

IF 3.2 4区 医学 Q2 PHARMACOLOGY & PHARMACY Clinical therapeutics Pub Date : 2024-11-07 DOI:10.1016/j.clinthera.2024.10.004
Meital Mishali, Nadav Sheffer, Oren Mishali, Maya Negev
{"title":"Understanding Variation Among Medical Device Reporting Sources: A Study of the MAUDE Database.","authors":"Meital Mishali, Nadav Sheffer, Oren Mishali, Maya Negev","doi":"10.1016/j.clinthera.2024.10.004","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Increasing medical device usage raises concerns regarding unexpected, potentially life-threatening events that pose public health risks. Such events are reported to the Food and Drug Administration (FDA), and cataloged in the Manufacturer and User Facility Device Experience (MAUDE) database, a vital tool for post market surveillance that requires information of high quality and integrity, particularly concerning reporting sources.</p><p><strong>Purpose: </strong>To analyze reporting behavior among different reporters, including manufacturers, distributors, and user facilities, by examining differences in reported factors, namely: (1) device types, (2) product problem attribution, and (3) selection of Device Problem Codes (DPCs) associated with the root causes of events.</p><p><strong>Methods: </strong>Data spanning from 2005 to 2022 was retrieved from the MAUDE database using Python. Reports were grouped by reporter type and divided according to device type, and the reporter's indication of association with a product problem. Furthermore, events were classified by their respective DPCs, which were manually grouped into four categories: device issues, user issues, clinical issues, or unknown.</p><p><strong>Findings: </strong>The analysis revealed significant variations among reporters across all examined aspects (P < 0.00001 in all comparisons according to the proportion test). Manufacturers predominantly focused on infusion pumps (10.1%) and Implant, Endosseous, Root-Form (IER) devices (7.6%), with a product problem indication rate of 29.2% in their reports. Device issues codes were the most frequently observed category in their reports, comprising 36.3%, followed by unknown codes (32%) and clinical codes (19.3%). Distributors, on the other hand, primarily reported on IER devices (89%) and exhibited the lowest product problem indication rate at 2.7%. Clinical issues codes predominated in their reports, constituting 85.7%, followed by unknown codes (6.7%). User facilities concentrated on intravascular sets (4.7%), Electrosurgical, Cutting & Coagulation & Accessories (4.2%), and Ventricular (Assist) Bypass (4.1%). Remarkably, their product problem indication rate was the highest at 56.7%. They predominantly reported device issues codes (54.3%), followed by use codes (30.8%), and unknown codes (11.4%) IMPLICATIONS: The notable variation among different reporters underscores the importance of incorporating diverse sources when analyzing the database, particularly in cases where majority of reports originate from manufacturers. Decision-makers must approach database information comprehensively, considering data sources and diverse perspectives to inform regulatory decisions effectively. Developing strategies that encourage various reporters to contribute their unique and complementary viewpoints is advisable.</p>","PeriodicalId":10699,"journal":{"name":"Clinical therapeutics","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clinthera.2024.10.004","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Increasing medical device usage raises concerns regarding unexpected, potentially life-threatening events that pose public health risks. Such events are reported to the Food and Drug Administration (FDA), and cataloged in the Manufacturer and User Facility Device Experience (MAUDE) database, a vital tool for post market surveillance that requires information of high quality and integrity, particularly concerning reporting sources.

Purpose: To analyze reporting behavior among different reporters, including manufacturers, distributors, and user facilities, by examining differences in reported factors, namely: (1) device types, (2) product problem attribution, and (3) selection of Device Problem Codes (DPCs) associated with the root causes of events.

Methods: Data spanning from 2005 to 2022 was retrieved from the MAUDE database using Python. Reports were grouped by reporter type and divided according to device type, and the reporter's indication of association with a product problem. Furthermore, events were classified by their respective DPCs, which were manually grouped into four categories: device issues, user issues, clinical issues, or unknown.

Findings: The analysis revealed significant variations among reporters across all examined aspects (P < 0.00001 in all comparisons according to the proportion test). Manufacturers predominantly focused on infusion pumps (10.1%) and Implant, Endosseous, Root-Form (IER) devices (7.6%), with a product problem indication rate of 29.2% in their reports. Device issues codes were the most frequently observed category in their reports, comprising 36.3%, followed by unknown codes (32%) and clinical codes (19.3%). Distributors, on the other hand, primarily reported on IER devices (89%) and exhibited the lowest product problem indication rate at 2.7%. Clinical issues codes predominated in their reports, constituting 85.7%, followed by unknown codes (6.7%). User facilities concentrated on intravascular sets (4.7%), Electrosurgical, Cutting & Coagulation & Accessories (4.2%), and Ventricular (Assist) Bypass (4.1%). Remarkably, their product problem indication rate was the highest at 56.7%. They predominantly reported device issues codes (54.3%), followed by use codes (30.8%), and unknown codes (11.4%) IMPLICATIONS: The notable variation among different reporters underscores the importance of incorporating diverse sources when analyzing the database, particularly in cases where majority of reports originate from manufacturers. Decision-makers must approach database information comprehensively, considering data sources and diverse perspectives to inform regulatory decisions effectively. Developing strategies that encourage various reporters to contribute their unique and complementary viewpoints is advisable.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical therapeutics
Clinical therapeutics 医学-药学
CiteScore
6.00
自引率
3.10%
发文量
154
审稿时长
9 weeks
期刊介绍: Clinical Therapeutics provides peer-reviewed, rapid publication of recent developments in drug and other therapies as well as in diagnostics, pharmacoeconomics, health policy, treatment outcomes, and innovations in drug and biologics research. In addition Clinical Therapeutics features updates on specific topics collated by expert Topic Editors. Clinical Therapeutics is read by a large international audience of scientists and clinicians in a variety of research, academic, and clinical practice settings. Articles are indexed by all major biomedical abstracting databases.
期刊最新文献
The Role of Sex and Gender in Precision Emergency Medicine: A Scoping Review and Proposed Hierarchy. Sex Differences in Testing for Pulmonary Embolism Among Emergency Department Patients Aged 18-49 by Chief Complaint. The Efficacy Research of Prophylactic PEG-rhG-CSF in Preventing Neutropenia in Early-Stage Breast Cancer Patients Treated With Docetaxel-Based Chemotherapy: A Retrospective Analysis. Correlation Between Vitamin D, Inflammatory Markers, and T Lymphocytes With the Severity of Chronic Obstructive Pulmonary Disease and its Effect on the Risk of Acute Exacerbation: A Single Cross-sectional Study. Understanding Variation Among Medical Device Reporting Sources: A Study of the MAUDE Database.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1