Fluoride release and flexural strength of four ion-releasing restorative materials: An in vitro comparative study.

Patricia Llancari-Alonzo, Daniel Alvítez-Temoche, Marysela Ladera-Castañeda, Leonor Castro-Ramirez, Carlos López-Gurreonero, César Cayo-Rojas
{"title":"Fluoride release and flexural strength of four ion-releasing restorative materials: An in vitro comparative study.","authors":"Patricia Llancari-Alonzo, Daniel Alvítez-Temoche, Marysela Ladera-Castañeda, Leonor Castro-Ramirez, Carlos López-Gurreonero, César Cayo-Rojas","doi":"10.4317/jced.61818","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to determine the fluoride release and flexural strength of four ion-releasing restorative materials.</p><p><strong>Material and methods: </strong>A total of 80 samples of four different materials were prepared in standardized molds: Ketac Universal, Beautifil II, Cention N, and Equia Forte Fil. The fluoride release was quantified at 1, 3, 7, 14, and 28 days post-immersion using an ion-selective electrode. The flexural strength was measured with a universal testing machine after 7 days of immersion in deionized water. A one-factor intergroup ANOVA with Welch's robust variance and Games-Howell's post hoc was employed. To compare related measures, a Friedman test with Bonferroni's adjusted post hoc was employed. The <i>p</i>-value was set at 0.05.</p><p><strong>Results: </strong>At 7 days, significant differences were observed in the flexural strength of the four ion-releasing restorative materials (<i>p</i><0.001). The flexural strength values from highest to lowest were as follows: Cention N (97.10 ± 4.99 MPa), Beautifil (82.77 ± 5.30 MPa), Equia Forte Fil (31.38 ± 7.68 MPa), and Ketac Universal (19.23 ± 2.94 MPa). In addition, at 3 and 7 days, the highest amount of fluoride released was observed for Cention N compared to the other ion-releasing restorative materials (<i>p</i><0.05). Conversely, Beautifil II released the lowest amount of fluoride at 3, 7, 14, and 28 days (<i>p</i><0.05) compared to the other ion-releasing restorative materials.</p><p><strong>Conclusions: </strong>The immersion of all ion-releasing restorative materials in deionized water for seven days resulted in significant differences in flexural strength. Cention N had the highest value, while Ketac Universal had the lowest. All ion-releasing restorative materials released fluoride at all test times, with Ketac Universal releasing the most at 1, 14, and 28 days, and Cention N releasing it at 3 and 7 days. Beautifil II showed the lowest fluoride release at all evaluated times, exhibiting a nearly constant release over time compared to the other materials. <b>Key words:</b>Fluoride release, flexural strength, glass ionomer.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"16 10","pages":"e1207-e1216"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559120/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.61818","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aimed to determine the fluoride release and flexural strength of four ion-releasing restorative materials.

Material and methods: A total of 80 samples of four different materials were prepared in standardized molds: Ketac Universal, Beautifil II, Cention N, and Equia Forte Fil. The fluoride release was quantified at 1, 3, 7, 14, and 28 days post-immersion using an ion-selective electrode. The flexural strength was measured with a universal testing machine after 7 days of immersion in deionized water. A one-factor intergroup ANOVA with Welch's robust variance and Games-Howell's post hoc was employed. To compare related measures, a Friedman test with Bonferroni's adjusted post hoc was employed. The p-value was set at 0.05.

Results: At 7 days, significant differences were observed in the flexural strength of the four ion-releasing restorative materials (p<0.001). The flexural strength values from highest to lowest were as follows: Cention N (97.10 ± 4.99 MPa), Beautifil (82.77 ± 5.30 MPa), Equia Forte Fil (31.38 ± 7.68 MPa), and Ketac Universal (19.23 ± 2.94 MPa). In addition, at 3 and 7 days, the highest amount of fluoride released was observed for Cention N compared to the other ion-releasing restorative materials (p<0.05). Conversely, Beautifil II released the lowest amount of fluoride at 3, 7, 14, and 28 days (p<0.05) compared to the other ion-releasing restorative materials.

Conclusions: The immersion of all ion-releasing restorative materials in deionized water for seven days resulted in significant differences in flexural strength. Cention N had the highest value, while Ketac Universal had the lowest. All ion-releasing restorative materials released fluoride at all test times, with Ketac Universal releasing the most at 1, 14, and 28 days, and Cention N releasing it at 3 and 7 days. Beautifil II showed the lowest fluoride release at all evaluated times, exhibiting a nearly constant release over time compared to the other materials. Key words:Fluoride release, flexural strength, glass ionomer.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
四种离子释放修复材料的氟释放和抗折强度:体外比较研究
背景:本研究旨在确定四种离子释放修复材料的氟释放量和挠曲强度:本研究旨在确定四种离子释放修复材料的氟释放量和抗折强度:在标准模具中制备了四种不同材料的共 80 个样品:Ketac Universal、Beautifil II、Cention N 和 Equia Forte Fil。使用离子选择电极对浸泡后 1、3、7、14 和 28 天的氟释放量进行量化。在去离子水中浸泡 7 天后,用万能试验机测量弯曲强度。采用单因素组间方差分析和韦尔奇稳健方差分析,以及 Games-Howell 后检验。为了比较相关指标,采用了 Friedman 检验和 Bonferroni 调整后检验。结果:结果:7 天时,四种离子释放修复材料的抗弯强度存在明显差异(ppp 结论:所有离子释放修复材料的浸泡时间均为 7 天:将所有离子释放修复材料在去离子水中浸泡 7 天后,其抗弯强度有显著差异。Cention N 的值最高,而 Ketac Universal 的值最低。所有离子释放修复材料在所有测试时间都会释放氟,其中 Ketac Universal 在 1 天、14 天和 28 天时释放量最大,Cention N 在 3 天和 7 天时释放量最大。Beautifil II 在所有测试时间内的氟释放量最低,与其他材料相比,它在一段时间内的氟释放量几乎是恒定的。关键词:氟释放、抗弯强度、玻璃离聚体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
118
期刊介绍: Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery
期刊最新文献
12th CONSEURO and the 25th National and 12th International SEOC Congress, April 3-5, 2025, Cordoba, Spain. Accuracy of the London Atlas and RP Atlas in age estimation of Southern Brazilians. Evaluation of preventive methods used to interrupt the progression of early caries lesions. Frequency TMJ disc displacements. Influence of age and sex on platelet count: Implications for optimizing growth factor-rich plasma preparation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1