Evaluation of V-type titanium cable internal fixation for the treatment of young adult fifth lumbar spondylolysis: technical notes and a retrospective clinical study.
Xiaoxia Huang, Yong Teng, Rui Ma, Wei An, Tao Liu, Li Qiang, Xiao Hui, Ye Kai
{"title":"Evaluation of V-type titanium cable internal fixation for the treatment of young adult fifth lumbar spondylolysis: technical notes and a retrospective clinical study.","authors":"Xiaoxia Huang, Yong Teng, Rui Ma, Wei An, Tao Liu, Li Qiang, Xiao Hui, Ye Kai","doi":"10.1186/s13018-024-05197-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Various strategies, each with its own set of limitations, are available for managing lumbar spondylolysis. In response, our department has developed an innovative solution: a V-shaped titanium cable integrated with a pedicle screw internal fixation system specifically designed for lumbar spondylolysis in young adults.</p><p><strong>Aim: </strong>The objective of this study was to thoroughly investigate the long-term efficacy of V-type titanium cable internal fixation for the management of spondylolysis, especially in young adults.</p><p><strong>Methods: </strong>Twenty-one patients with fifth lumbar spondylolysis were treated using V-shaped titanium cables and pedicle screw internal fixation at the General Hospital Xinjiang Military Command. The duration of low back pain before surgery was 6 ~ 48 (15.85 ± 11.57) months. The Medtronic (S7) navigation system was used during surgery to guide the placement of pedicle screws, aiming to avoid damaging the L4-5 facet joint by positioning the screws lower and further to the side. Intraoperative indices (operative time and intraoperative blood loss) were recorded. The visual analog scale (VAS), Oswestry Disability Index (ODI), pelvic incidence (PI), and intraoperative imaging measurements of screw accuracy were meticulously recorded and assessed in a comprehensive manner. This thorough evaluation was conducted both intraoperatively and throughout the follow-up period, which lasted for at least one year.The Macnab efficacy criteria were used to assess postoperative outcomes during the final follow-up period.</p><p><strong>Results: </strong>All patients successfully completed the 1-year follow-up on time. Two patients experienced postoperative wound liquefaction and successfully recovered after undergoing dressing changes. The average duration of the surgical procedure was 113.09 ± 6.97 min, and an intraoperative blood loss of 50.47 ± 21.32 millilitres was observed. Significant differences were noted in visual analog scale (VAS) scores before and after surgery at various time intervals, indicating improvement with the progression of rehabilitation exercises. No significant changes were found in the pelvic incidence (PI), and there were no notable differences between the preoperative and postoperative periods. No loosening, breakage, or failure of the internal fixation was found during the long-term follow-up. Furthermore, there were no serious complications, such as infection or vascular or nerve injuries. occurred during the procedure. A patient who presented with a considerable cryptic fissure of sacrum 1 experienced dural injury during the surgical procedure. Intraoperatively, dural sutures were skillfully applied, and the adjacent muscles were fortified. Remarkably, the patient achieved successful healing in a single stage. On the first day postsurgery, a gradual improvement in mobility was noted.</p><p><strong>Conclusions: </strong>The use of a V-shaped titanium cable in conjunction with a pedicle screw internal fixation system for the management of fifth lumbar spondylolysis in young individuals is characterized by its ease of execution and ability to yield favorable outcomes. This approach relies on the prerequisite that patients with minimal intervertebral disc injury or mild lumbar spondylolisthesis demonstrate high overall success rates but experience low failure rates associated with internal fixation. Most significantly, this technique involves segmental internal fixation, which safeguards the functional spinal unit (FSU).</p>","PeriodicalId":16629,"journal":{"name":"Journal of Orthopaedic Surgery and Research","volume":"19 1","pages":"747"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559233/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13018-024-05197-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Various strategies, each with its own set of limitations, are available for managing lumbar spondylolysis. In response, our department has developed an innovative solution: a V-shaped titanium cable integrated with a pedicle screw internal fixation system specifically designed for lumbar spondylolysis in young adults.
Aim: The objective of this study was to thoroughly investigate the long-term efficacy of V-type titanium cable internal fixation for the management of spondylolysis, especially in young adults.
Methods: Twenty-one patients with fifth lumbar spondylolysis were treated using V-shaped titanium cables and pedicle screw internal fixation at the General Hospital Xinjiang Military Command. The duration of low back pain before surgery was 6 ~ 48 (15.85 ± 11.57) months. The Medtronic (S7) navigation system was used during surgery to guide the placement of pedicle screws, aiming to avoid damaging the L4-5 facet joint by positioning the screws lower and further to the side. Intraoperative indices (operative time and intraoperative blood loss) were recorded. The visual analog scale (VAS), Oswestry Disability Index (ODI), pelvic incidence (PI), and intraoperative imaging measurements of screw accuracy were meticulously recorded and assessed in a comprehensive manner. This thorough evaluation was conducted both intraoperatively and throughout the follow-up period, which lasted for at least one year.The Macnab efficacy criteria were used to assess postoperative outcomes during the final follow-up period.
Results: All patients successfully completed the 1-year follow-up on time. Two patients experienced postoperative wound liquefaction and successfully recovered after undergoing dressing changes. The average duration of the surgical procedure was 113.09 ± 6.97 min, and an intraoperative blood loss of 50.47 ± 21.32 millilitres was observed. Significant differences were noted in visual analog scale (VAS) scores before and after surgery at various time intervals, indicating improvement with the progression of rehabilitation exercises. No significant changes were found in the pelvic incidence (PI), and there were no notable differences between the preoperative and postoperative periods. No loosening, breakage, or failure of the internal fixation was found during the long-term follow-up. Furthermore, there were no serious complications, such as infection or vascular or nerve injuries. occurred during the procedure. A patient who presented with a considerable cryptic fissure of sacrum 1 experienced dural injury during the surgical procedure. Intraoperatively, dural sutures were skillfully applied, and the adjacent muscles were fortified. Remarkably, the patient achieved successful healing in a single stage. On the first day postsurgery, a gradual improvement in mobility was noted.
Conclusions: The use of a V-shaped titanium cable in conjunction with a pedicle screw internal fixation system for the management of fifth lumbar spondylolysis in young individuals is characterized by its ease of execution and ability to yield favorable outcomes. This approach relies on the prerequisite that patients with minimal intervertebral disc injury or mild lumbar spondylolisthesis demonstrate high overall success rates but experience low failure rates associated with internal fixation. Most significantly, this technique involves segmental internal fixation, which safeguards the functional spinal unit (FSU).
期刊介绍:
Journal of Orthopaedic Surgery and Research is an open access journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal issues.
Orthopaedic research is conducted at clinical and basic science levels. With the advancement of new technologies and the increasing expectation and demand from doctors and patients, we are witnessing an enormous growth in clinical orthopaedic research, particularly in the fields of traumatology, spinal surgery, joint replacement, sports medicine, musculoskeletal tumour management, hand microsurgery, foot and ankle surgery, paediatric orthopaedic, and orthopaedic rehabilitation. The involvement of basic science ranges from molecular, cellular, structural and functional perspectives to tissue engineering, gait analysis, automation and robotic surgery. Implant and biomaterial designs are new disciplines that complement clinical applications.
JOSR encourages the publication of multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines, which will be the trend in the coming decades.