Evaluation of V-type titanium cable internal fixation for the treatment of young adult fifth lumbar spondylolysis: technical notes and a retrospective clinical study.

IF 2.8 3区 医学 Q1 ORTHOPEDICS Journal of Orthopaedic Surgery and Research Pub Date : 2024-11-13 DOI:10.1186/s13018-024-05197-7
Xiaoxia Huang, Yong Teng, Rui Ma, Wei An, Tao Liu, Li Qiang, Xiao Hui, Ye Kai
{"title":"Evaluation of V-type titanium cable internal fixation for the treatment of young adult fifth lumbar spondylolysis: technical notes and a retrospective clinical study.","authors":"Xiaoxia Huang, Yong Teng, Rui Ma, Wei An, Tao Liu, Li Qiang, Xiao Hui, Ye Kai","doi":"10.1186/s13018-024-05197-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Various strategies, each with its own set of limitations, are available for managing lumbar spondylolysis. In response, our department has developed an innovative solution: a V-shaped titanium cable integrated with a pedicle screw internal fixation system specifically designed for lumbar spondylolysis in young adults.</p><p><strong>Aim: </strong>The objective of this study was to thoroughly investigate the long-term efficacy of V-type titanium cable internal fixation for the management of spondylolysis, especially in young adults.</p><p><strong>Methods: </strong>Twenty-one patients with fifth lumbar spondylolysis were treated using V-shaped titanium cables and pedicle screw internal fixation at the General Hospital Xinjiang Military Command. The duration of low back pain before surgery was 6 ~ 48 (15.85 ± 11.57) months. The Medtronic (S7) navigation system was used during surgery to guide the placement of pedicle screws, aiming to avoid damaging the L4-5 facet joint by positioning the screws lower and further to the side. Intraoperative indices (operative time and intraoperative blood loss) were recorded. The visual analog scale (VAS), Oswestry Disability Index (ODI), pelvic incidence (PI), and intraoperative imaging measurements of screw accuracy were meticulously recorded and assessed in a comprehensive manner. This thorough evaluation was conducted both intraoperatively and throughout the follow-up period, which lasted for at least one year.The Macnab efficacy criteria were used to assess postoperative outcomes during the final follow-up period.</p><p><strong>Results: </strong>All patients successfully completed the 1-year follow-up on time. Two patients experienced postoperative wound liquefaction and successfully recovered after undergoing dressing changes. The average duration of the surgical procedure was 113.09 ± 6.97 min, and an intraoperative blood loss of 50.47 ± 21.32 millilitres was observed. Significant differences were noted in visual analog scale (VAS) scores before and after surgery at various time intervals, indicating improvement with the progression of rehabilitation exercises. No significant changes were found in the pelvic incidence (PI), and there were no notable differences between the preoperative and postoperative periods. No loosening, breakage, or failure of the internal fixation was found during the long-term follow-up. Furthermore, there were no serious complications, such as infection or vascular or nerve injuries. occurred during the procedure. A patient who presented with a considerable cryptic fissure of sacrum 1 experienced dural injury during the surgical procedure. Intraoperatively, dural sutures were skillfully applied, and the adjacent muscles were fortified. Remarkably, the patient achieved successful healing in a single stage. On the first day postsurgery, a gradual improvement in mobility was noted.</p><p><strong>Conclusions: </strong>The use of a V-shaped titanium cable in conjunction with a pedicle screw internal fixation system for the management of fifth lumbar spondylolysis in young individuals is characterized by its ease of execution and ability to yield favorable outcomes. This approach relies on the prerequisite that patients with minimal intervertebral disc injury or mild lumbar spondylolisthesis demonstrate high overall success rates but experience low failure rates associated with internal fixation. Most significantly, this technique involves segmental internal fixation, which safeguards the functional spinal unit (FSU).</p>","PeriodicalId":16629,"journal":{"name":"Journal of Orthopaedic Surgery and Research","volume":"19 1","pages":"747"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559233/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery and Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13018-024-05197-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Various strategies, each with its own set of limitations, are available for managing lumbar spondylolysis. In response, our department has developed an innovative solution: a V-shaped titanium cable integrated with a pedicle screw internal fixation system specifically designed for lumbar spondylolysis in young adults.

Aim: The objective of this study was to thoroughly investigate the long-term efficacy of V-type titanium cable internal fixation for the management of spondylolysis, especially in young adults.

Methods: Twenty-one patients with fifth lumbar spondylolysis were treated using V-shaped titanium cables and pedicle screw internal fixation at the General Hospital Xinjiang Military Command. The duration of low back pain before surgery was 6 ~ 48 (15.85 ± 11.57) months. The Medtronic (S7) navigation system was used during surgery to guide the placement of pedicle screws, aiming to avoid damaging the L4-5 facet joint by positioning the screws lower and further to the side. Intraoperative indices (operative time and intraoperative blood loss) were recorded. The visual analog scale (VAS), Oswestry Disability Index (ODI), pelvic incidence (PI), and intraoperative imaging measurements of screw accuracy were meticulously recorded and assessed in a comprehensive manner. This thorough evaluation was conducted both intraoperatively and throughout the follow-up period, which lasted for at least one year.The Macnab efficacy criteria were used to assess postoperative outcomes during the final follow-up period.

Results: All patients successfully completed the 1-year follow-up on time. Two patients experienced postoperative wound liquefaction and successfully recovered after undergoing dressing changes. The average duration of the surgical procedure was 113.09 ± 6.97 min, and an intraoperative blood loss of 50.47 ± 21.32 millilitres was observed. Significant differences were noted in visual analog scale (VAS) scores before and after surgery at various time intervals, indicating improvement with the progression of rehabilitation exercises. No significant changes were found in the pelvic incidence (PI), and there were no notable differences between the preoperative and postoperative periods. No loosening, breakage, or failure of the internal fixation was found during the long-term follow-up. Furthermore, there were no serious complications, such as infection or vascular or nerve injuries. occurred during the procedure. A patient who presented with a considerable cryptic fissure of sacrum 1 experienced dural injury during the surgical procedure. Intraoperatively, dural sutures were skillfully applied, and the adjacent muscles were fortified. Remarkably, the patient achieved successful healing in a single stage. On the first day postsurgery, a gradual improvement in mobility was noted.

Conclusions: The use of a V-shaped titanium cable in conjunction with a pedicle screw internal fixation system for the management of fifth lumbar spondylolysis in young individuals is characterized by its ease of execution and ability to yield favorable outcomes. This approach relies on the prerequisite that patients with minimal intervertebral disc injury or mild lumbar spondylolisthesis demonstrate high overall success rates but experience low failure rates associated with internal fixation. Most significantly, this technique involves segmental internal fixation, which safeguards the functional spinal unit (FSU).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
V型钛索内固定治疗年轻成人第五腰椎骨质增生的评估:技术说明和回顾性临床研究。
背景:目前有多种治疗腰椎间盘突出症的方法,但每种方法都有其自身的局限性。为此,我们科室开发了一种创新解决方案:V 型钛索与椎弓根螺钉内固定系统集成,专为青壮年腰椎间盘突出症而设计:新疆军区总医院采用V型钛缆和椎弓根螺钉内固定治疗了21例第五节腰椎骨质增生患者。术前腰痛持续时间为 6 ~ 48 (15.85 ± 11.57) 个月。手术中使用了美敦力(S7)导航系统来引导椎弓根螺钉的放置,目的是通过将螺钉放置在更低和更靠侧的位置来避免损伤L4-5面关节。术中指标(手术时间和术中失血量)均有记录。视觉模拟量表(VAS)、Oswestry 失能指数(ODI)、骨盆入量(PI)以及术中对螺钉准确性的影像学测量结果都得到了细致的记录和全面的评估。这一全面评估在术中和整个随访期间进行,随访期至少持续一年。在最后的随访期间,采用 Macnab 疗效标准评估术后效果:结果:所有患者都按时完成了为期一年的随访。结果:所有患者都按时完成了为期一年的随访,其中两名患者术后出现伤口液化,在更换敷料后成功恢复。手术时间平均为(113.09±6.97)分钟,术中失血量为(50.47±21.32)毫升。术前和术后不同时间段的视觉模拟量表(VAS)评分存在显著差异,表明随着康复锻炼的进行,情况有所改善。骨盆发生率(PI)没有明显变化,术前和术后也没有明显差异。长期随访中未发现内固定物松动、断裂或失效。此外,手术过程中也没有出现感染、血管或神经损伤等严重并发症。一名骶骨隐裂较大的患者在手术过程中硬膜损伤。术中巧妙地进行了硬膜缝合,并对邻近肌肉进行了加固。值得注意的是,患者在一个阶段内就获得了成功愈合。术后第一天,患者的活动能力就得到了逐步改善:结论:使用 V 型钛索结合椎弓根螺钉内固定系统治疗年轻人的第五腰椎骨质增生,具有操作简便、疗效显著的特点。这种方法的前提条件是,椎间盘损伤轻微或轻度腰椎滑脱的患者总体成功率高,但内固定失败率低。最重要的是,这种技术涉及节段性内固定,可保护脊柱功能单元(FSU)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
7.70%
发文量
494
审稿时长
>12 weeks
期刊介绍: Journal of Orthopaedic Surgery and Research is an open access journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal issues. Orthopaedic research is conducted at clinical and basic science levels. With the advancement of new technologies and the increasing expectation and demand from doctors and patients, we are witnessing an enormous growth in clinical orthopaedic research, particularly in the fields of traumatology, spinal surgery, joint replacement, sports medicine, musculoskeletal tumour management, hand microsurgery, foot and ankle surgery, paediatric orthopaedic, and orthopaedic rehabilitation. The involvement of basic science ranges from molecular, cellular, structural and functional perspectives to tissue engineering, gait analysis, automation and robotic surgery. Implant and biomaterial designs are new disciplines that complement clinical applications. JOSR encourages the publication of multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines, which will be the trend in the coming decades.
期刊最新文献
Comparison of surgical invasiveness and hidden blood loss between unilateral double portal endoscopic lumbar disc extraction and percutaneous endoscopic interlaminar discectomy for lumbar spinal stenosis. Effect of the orthogeriatric co-management on older hip fracture patients with multimorbidity: a post-hoc exploratory subgroup analysis of a non-randomised controlled trial. Pilot study on the in-vitro effect of radiation therapy on bending stiffness of intramedullary photodynamic implants. Comparison of three sacral screw internal fixation techniques in the treatment of L4-S1 lumbar degenerative disease with osteoporosis: a retrospective observational study. Correction: CRISPR activation identifies a novel miR-2861 binding site that facilitates the osteogenesis of human mesenchymal stem cells.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1