{"title":"[Determination of vitamin D<sub>3</sub> content in cod liver oil using a column-switching technique].","authors":"Lyuye Qi, Liyuan Zhang, Qiaoyuan Cheng, Linqi Yan, Minghao Zhou","doi":"10.3724/zdxbyxb-2024-0045","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To develop a two-dimensional liquid chromatography method to determine the content of vitamin D<sub>3</sub> in cod liver oil preparations.</p><p><strong>Methods: </strong>The samples were prepared by saponification and extraction, and the content of vitamin D<sub>3</sub> was determined by two-dimensional liquid chromatography with dual-pump-single-valve switching dual detectors. The chromatographic column, capture device, and detection wavelength were optimized; the linearity, system suitability, recovery rate, repeatability and sample stability of the method were investigated, and further validated in actual sample determination.</p><p><strong>Results: </strong>A column switching two-dimensional chromatography method was developed. In the first chromatography dimension, an Agilent PoroShell SB-C8 (50 mm×4.6 mm, 2.7 μm) column was used with acetonitrile-water as the mobile phase with gradient elution at a flow rate of 1.0 mL/min and detection wavelength as 264 nm. An Agilent Zorbax SB-C18 (150 mm×3.0 mm,1.8 μm) column was used in the second chromatography dimension with acetonitrile as the mobile phase at a flow rate of 0.42 mL/min, and detection wavelength as 264 nm. In determining vitamin D<sub>3</sub> content, there was a good linear relationship in the concentration range. The system suitability, recovery rate, repeatability and sample stability all met verification requirements.</p><p><strong>Conclusions: </strong>The two-dimensional liquid chromatography method developed in this study is accurate, reproducible and simple, and can simultaneously separate pre-vitamin D<sub>3</sub>, trans-vitamin D<sub>3</sub>, vitamin D<sub>3</sub>, and tachysterol D<sub>3</sub>.</p>","PeriodicalId":24007,"journal":{"name":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","volume":" ","pages":"779-784"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11736344/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/zdxbyxb-2024-0045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To develop a two-dimensional liquid chromatography method to determine the content of vitamin D3 in cod liver oil preparations.
Methods: The samples were prepared by saponification and extraction, and the content of vitamin D3 was determined by two-dimensional liquid chromatography with dual-pump-single-valve switching dual detectors. The chromatographic column, capture device, and detection wavelength were optimized; the linearity, system suitability, recovery rate, repeatability and sample stability of the method were investigated, and further validated in actual sample determination.
Results: A column switching two-dimensional chromatography method was developed. In the first chromatography dimension, an Agilent PoroShell SB-C8 (50 mm×4.6 mm, 2.7 μm) column was used with acetonitrile-water as the mobile phase with gradient elution at a flow rate of 1.0 mL/min and detection wavelength as 264 nm. An Agilent Zorbax SB-C18 (150 mm×3.0 mm,1.8 μm) column was used in the second chromatography dimension with acetonitrile as the mobile phase at a flow rate of 0.42 mL/min, and detection wavelength as 264 nm. In determining vitamin D3 content, there was a good linear relationship in the concentration range. The system suitability, recovery rate, repeatability and sample stability all met verification requirements.
Conclusions: The two-dimensional liquid chromatography method developed in this study is accurate, reproducible and simple, and can simultaneously separate pre-vitamin D3, trans-vitamin D3, vitamin D3, and tachysterol D3.