Effect of high-frequency oscillatory ventilation with intermittent sigh breaths on carbon dioxide levels in neonates.

IF 3.2 Q1 PEDIATRICS Clinical and Experimental Pediatrics Pub Date : 2024-11-13 DOI:10.3345/cep.2024.01011
Kulthida Baingam, Anucha Thatrimontrichai, Manapat Praditaukrit, Gunlawadee Maneenil, Supaporn Dissaneevate
{"title":"Effect of high-frequency oscillatory ventilation with intermittent sigh breaths on carbon dioxide levels in neonates.","authors":"Kulthida Baingam, Anucha Thatrimontrichai, Manapat Praditaukrit, Gunlawadee Maneenil, Supaporn Dissaneevate","doi":"10.3345/cep.2024.01011","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>High-frequency oscillatory ventilation (HFOV) minimizes ventilator-induced lung injuries. Spontaneous sigh breathing may augment the functional residual capacity, increase lung compliance, and recruit atelectatic alveoli.</p><p><strong>Purpose: </strong>To evaluate the difference in the partial pressure of carbon dioxide (PaCO2) in neonates receiving invasive HFOV as the primary mode of respiratory support before versus after sigh breaths (Sighs).</p><p><strong>Methods: </strong>This prospective study was conducted between January and December 2023. Intubated preterm and term neonates who underwent HFOV with an available arterial line were enrolled in this study after informed parental consent was obtained. Sighs were set at a frequency of 3 breaths/min and pressure of 5 cm H2O above the mean airway pressure for 2 hours. Arterial blood gas was collected before and after Sighs and analyzed using two dependent tests.</p><p><strong>Results: </strong>Thirty neonates with a mean gestational age of 33.6±4.1 weeks and median date of intervention of 1.88 (interquartile range, 0.87-3.79) days were enrolled. The mean PaCO2 level was significantly lower in the HFOV with Sighs group (45.2±6.6 mm Hg) versus the HFOV alone group (48.8±3.1 mm Hg) with a mean difference (MD) of -3.6 mm Hg (95% confidence interval [CI], -6.3 to -0.9; P=0.01). Subgroup analyses indicated the ability of Sighs to reduce the PaCO2 level in neonates with respiratory distress syndrome (n=15; MD [95% CI] = -4.2 [-8.2 to -0.2] mm Hg; P=0.04).</p>","PeriodicalId":36018,"journal":{"name":"Clinical and Experimental Pediatrics","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Pediatrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3345/cep.2024.01011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: High-frequency oscillatory ventilation (HFOV) minimizes ventilator-induced lung injuries. Spontaneous sigh breathing may augment the functional residual capacity, increase lung compliance, and recruit atelectatic alveoli.

Purpose: To evaluate the difference in the partial pressure of carbon dioxide (PaCO2) in neonates receiving invasive HFOV as the primary mode of respiratory support before versus after sigh breaths (Sighs).

Methods: This prospective study was conducted between January and December 2023. Intubated preterm and term neonates who underwent HFOV with an available arterial line were enrolled in this study after informed parental consent was obtained. Sighs were set at a frequency of 3 breaths/min and pressure of 5 cm H2O above the mean airway pressure for 2 hours. Arterial blood gas was collected before and after Sighs and analyzed using two dependent tests.

Results: Thirty neonates with a mean gestational age of 33.6±4.1 weeks and median date of intervention of 1.88 (interquartile range, 0.87-3.79) days were enrolled. The mean PaCO2 level was significantly lower in the HFOV with Sighs group (45.2±6.6 mm Hg) versus the HFOV alone group (48.8±3.1 mm Hg) with a mean difference (MD) of -3.6 mm Hg (95% confidence interval [CI], -6.3 to -0.9; P=0.01). Subgroup analyses indicated the ability of Sighs to reduce the PaCO2 level in neonates with respiratory distress syndrome (n=15; MD [95% CI] = -4.2 [-8.2 to -0.2] mm Hg; P=0.04).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
间歇叹气的高频振荡通气对新生儿二氧化碳水平的影响。
背景:高频振荡通气(HFOV)可将呼吸机诱发的肺损伤降至最低。目的:评估以有创高频振荡通气(HFOV)为主要呼吸支持模式的新生儿在叹息呼吸(Sighs)前后二氧化碳分压(PaCO2)的差异:这项前瞻性研究在 2023 年 1 月至 12 月期间进行。这项前瞻性研究在 2023 年 1 月至 12 月期间进行,插管的早产儿和足月新生儿在获得父母知情同意后,均接受了有动脉管路的高频氧合监护。叹气的频率设定为 3 次/分钟,压力设定为高于平均气道压 5 厘米 H2O,持续 2 小时。在叹气前后收集动脉血气,并使用两个从属检验进行分析:结果:30 名新生儿的平均胎龄为 33.6±4.1 周,干预日期的中位数为 1.88 天(四分位距为 0.87-3.79 天)。使用叹气的 HFOV 组的平均 PaCO2 水平(45.2±6.6 mm Hg)明显低于单用 HFOV 组(48.8±3.1 mm Hg),平均差 (MD) 为 -3.6 mm Hg(95% 置信区间 [CI],-6.3 至 -0.9;P=0.01)。分组分析表明,叹息能降低患有呼吸窘迫综合征的新生儿的 PaCO2 水平(n=15;MD [95% CI] = -4.2 [-8.2 to -0.2] mm Hg;P=0.04)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.00
自引率
2.40%
发文量
88
审稿时长
60 weeks
期刊最新文献
Absolute versus functional iron deficiency. Characteristics of temper tantrums in 1-6-year-old children and impact on caregivers. Effect of high-frequency oscillatory ventilation with intermittent sigh breaths on carbon dioxide levels in neonates. Effect of metabolic syndrome on pulmonary dysfunction in children with asthma. Further research on impact of microplastics on children's health is essential to protecting future generations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1