A bright cyan fluorescence calcium indicator for mitochondrial calcium with minimal interference from physiological pH fluctuations.

Wenjia Gu, Yuqin Yang, Yuqing Wang, Jia Li, Wanjie Li, Xiaoyan Zhang, Hao Dong, Youjun Wang
{"title":"A bright cyan fluorescence calcium indicator for mitochondrial calcium with minimal interference from physiological pH fluctuations.","authors":"Wenjia Gu, Yuqin Yang, Yuqing Wang, Jia Li, Wanjie Li, Xiaoyan Zhang, Hao Dong, Youjun Wang","doi":"10.52601/bpr.2024.240001","DOIUrl":null,"url":null,"abstract":"<p><p>Genetically Encoded Calcium (Ca<sup>2+</sup>) indicators (GECIs) are indispensable tools for dissecting intracellular Ca<sup>2+</sup> signaling and monitoring cellular activities. Mitochondrion acts as a Ca<sup>2+</sup> sink and a central player for maintaining Ca<sup>2+</sup> homeostasis. Accurately monitoring Ca<sup>2+</sup> transients within the mitochondrial matrix that undergo constant pH fluctuations is challenging, as signals of most currently available GECIs suffer from artifacts induced by physiological pH variations. Multiplexed monitoring of optophysiology is also hindered by the limited availability of GECIs with cyan fluorescence. Based on the bright variant of cyan fluorescence protein (CFP), mTurquoise2, we developed a GECI designated as TurCaMP. Results from molecular dynamics simulations and <i>ab initio</i> calculations revealed that the deprotonation of the chromophore may be responsible for the Ca<sup>2+</sup>-dependent changes in TurCaMP signals. TurCaMP sensors showed inverse response to Ca<sup>2+</sup> transients, and their responses were not affected by pH changes within the range of pH 6-9. The high basal fluorescence and insensitivity to physiological pH fluctuations enabled TurCaMP to faithfully monitor mitochondrial Ca<sup>2+</sup> responses with a high signal-to-noise ratio. TurCaMP sensors allow simultaneous multi-colored imaging of intracellular Ca<sup>2+</sup> signals, expanding the possibility of multiplexed monitoring of Ca<sup>2+</sup>-dependent physiological events.</p>","PeriodicalId":93906,"journal":{"name":"Biophysics reports","volume":"10 5","pages":"315-327"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11554577/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophysics reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52601/bpr.2024.240001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Genetically Encoded Calcium (Ca2+) indicators (GECIs) are indispensable tools for dissecting intracellular Ca2+ signaling and monitoring cellular activities. Mitochondrion acts as a Ca2+ sink and a central player for maintaining Ca2+ homeostasis. Accurately monitoring Ca2+ transients within the mitochondrial matrix that undergo constant pH fluctuations is challenging, as signals of most currently available GECIs suffer from artifacts induced by physiological pH variations. Multiplexed monitoring of optophysiology is also hindered by the limited availability of GECIs with cyan fluorescence. Based on the bright variant of cyan fluorescence protein (CFP), mTurquoise2, we developed a GECI designated as TurCaMP. Results from molecular dynamics simulations and ab initio calculations revealed that the deprotonation of the chromophore may be responsible for the Ca2+-dependent changes in TurCaMP signals. TurCaMP sensors showed inverse response to Ca2+ transients, and their responses were not affected by pH changes within the range of pH 6-9. The high basal fluorescence and insensitivity to physiological pH fluctuations enabled TurCaMP to faithfully monitor mitochondrial Ca2+ responses with a high signal-to-noise ratio. TurCaMP sensors allow simultaneous multi-colored imaging of intracellular Ca2+ signals, expanding the possibility of multiplexed monitoring of Ca2+-dependent physiological events.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
线粒体钙的亮青色荧光钙指示剂,受生理 pH 值波动的干扰极小。
基因编码钙(Ca2+)指示剂(GECIs)是剖析细胞内 Ca2+ 信号传导和监测细胞活动不可或缺的工具。线粒体是 Ca2+ 的汇,也是维持 Ca2+ 平衡的核心。准确监测线粒体基质内不断发生 pH 值波动的 Ca2+ 瞬态具有挑战性,因为目前大多数可用的 GECI 信号都受到生理 pH 值变化引起的伪差的影响。青色荧光的 GECIs 数量有限,也阻碍了对光生理学的多重监测。基于青色荧光蛋白(CFP)的明亮变体 mTurquoise2,我们开发了一种 GECI,命名为 TurCaMP。分子动力学模拟和 ab initio 计算的结果表明,发色团的去质子化可能是 TurCaMP 信号随 Ca2+ 变化的原因。TurCaMP 传感器对 Ca2+ 瞬变的反应呈反向,在 pH 6-9 范围内,其反应不受 pH 值变化的影响。高基础荧光和对生理 pH 值波动的不敏感性使 TurCaMP 能够以高信噪比忠实地监测线粒体 Ca2+ 反应。TurCaMP 传感器可同时对细胞内 Ca2+ 信号进行多色成像,从而扩大了对 Ca2+ 依赖性生理事件进行多重监测的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
A rapid and reproducible method for generating germ-free Drosophila melanogaster. A prognostic model for acute myeloid leukemia based on ferroptosis-related lncRNA and immune infiltration analysis. Characterization of auditory sensation in C. elegans. Current status of FAP-directed cancer theranostics: a bibliometric analysis. Mechanism and application of mesenchymal stem cells and their secreting extracellular vesicles in regulating CD4+T cells in immune diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1