Lesion characteristics of long application time ablation using unipolar half-normal saline irrigation and bipolar normal saline irrigation.

Takumi Kasai, Osamu Saitoh, Ayaka Oikawa, Naomasa Suzuki, Yasuhiro Ikami, Yuki Hasegawa, Sou Otsuki, Takayuki Inomata, Hiroshi Furushima, Masaomi Chinushi
{"title":"Lesion characteristics of long application time ablation using unipolar half-normal saline irrigation and bipolar normal saline irrigation.","authors":"Takumi Kasai, Osamu Saitoh, Ayaka Oikawa, Naomasa Suzuki, Yasuhiro Ikami, Yuki Hasegawa, Sou Otsuki, Takayuki Inomata, Hiroshi Furushima, Masaomi Chinushi","doi":"10.1016/j.ipej.2024.11.003","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Unipolar radiofrequency (RF) ablation using half-normal saline irrigation (UNIP-HNS) and bipolar RF ablation using normal saline irrigation (BIP-NS) are effective to treat arrhythmias from inside thick myocardium. However, differences between these two ablations when using a long application time had not fully been studied.</p><p><strong>Methods: </strong>UNIP-HNS, BIP-NS and unipolar RF ablation using normal saline irrigation (UNIP-NS) were applied for 120 s (30 W and 20-g contact) to porcine endocardial wall (≧15.0 mm thickness).</p><p><strong>Results: </strong>All ablations (30 applications each in UNIP-HNS and BIP-NS, and 20 applications in UNIP-NS) were successfully accomplished without steam-pop. Total impedance decline was largest in BIP-NS followed by UNIP-HNS and UNIP-NS. UNIP-HNS created larger surface lesions and greater maximum lesion width under the surface than those by UNIP-NS and BIP-NS. Endocardial lesion depth in UNIP-HNS and BIP-NS were deeper than that in UNIP-NS, but with no difference between UNIP-HNS and BIP-NS, when selecting non-transmural lesions. Similar results were obtained when all lesions (non-transmural and transmural) were included and endocardial lesion depth of the transmural lesions (13/30 applications of BIP-NS) was estimated as 50 % of the myocardial thickness. Lesion length in the transverse myocardial wall (endocardial plus epicardial lesions) was greatest in BIP-NS.</p><p><strong>Conclusions: </strong>Longer application time ablation (30 W) targeting the thick myocardium was performable in UNIP-HNS and BIP-NS. Since a transmural lesion and/or a deeper lesion into the myocardial wall are created, BIP-NS is preferable if two ablation catheters can be positioned on either side of the target.</p>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ipej.2024.11.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Unipolar radiofrequency (RF) ablation using half-normal saline irrigation (UNIP-HNS) and bipolar RF ablation using normal saline irrigation (BIP-NS) are effective to treat arrhythmias from inside thick myocardium. However, differences between these two ablations when using a long application time had not fully been studied.

Methods: UNIP-HNS, BIP-NS and unipolar RF ablation using normal saline irrigation (UNIP-NS) were applied for 120 s (30 W and 20-g contact) to porcine endocardial wall (≧15.0 mm thickness).

Results: All ablations (30 applications each in UNIP-HNS and BIP-NS, and 20 applications in UNIP-NS) were successfully accomplished without steam-pop. Total impedance decline was largest in BIP-NS followed by UNIP-HNS and UNIP-NS. UNIP-HNS created larger surface lesions and greater maximum lesion width under the surface than those by UNIP-NS and BIP-NS. Endocardial lesion depth in UNIP-HNS and BIP-NS were deeper than that in UNIP-NS, but with no difference between UNIP-HNS and BIP-NS, when selecting non-transmural lesions. Similar results were obtained when all lesions (non-transmural and transmural) were included and endocardial lesion depth of the transmural lesions (13/30 applications of BIP-NS) was estimated as 50 % of the myocardial thickness. Lesion length in the transverse myocardial wall (endocardial plus epicardial lesions) was greatest in BIP-NS.

Conclusions: Longer application time ablation (30 W) targeting the thick myocardium was performable in UNIP-HNS and BIP-NS. Since a transmural lesion and/or a deeper lesion into the myocardial wall are created, BIP-NS is preferable if two ablation catheters can be positioned on either side of the target.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用单极半生理盐水灌注和双极生理盐水灌注进行长应用时间消融的病变特征。
简介:使用半生理盐水灌注的单极射频消融术(UNIP-HNS)和使用生理盐水灌注的双极射频消融术(BIP-NS)可有效治疗厚心肌内的心律失常。然而,这两种消融术在长时间应用时的差异尚未得到充分研究:方法:在猪心内膜壁(厚度≧15.0 毫米)上应用 UNIP-HNS、BIP-NS 和使用生理盐水灌注的单极射频消融术(UNIP-NS)120 秒(30 瓦和 20 克接触):所有消融(UNIP-HNS 和 BIP-NS 各 30 次,UNIP-NS 20 次)均在无蒸汽冲击的情况下成功完成。BIP-NS 的总阻抗下降幅度最大,其次是 UNIP-HNS 和 UNIP-NS。与 UNIP-NS 和 BIP-NS 相比,UNIP-HNS 造成的表面病变更大,表面下的最大病变宽度也更大。在选择非横纹肌病变时,UNIP-HNS 和 BIP-NS 的心内膜病变深度比 UNIP-NS 深,但 UNIP-HNS 和 BIP-NS 之间没有差异。如果将所有病变(非横纹肌病变和横纹肌病变)都包括在内,并将横纹肌病变(BIP-NS 的 13/30 次应用)的心内膜病变深度估计为心肌厚度的 50%,也会得到类似的结果。横向心肌壁的病变长度(心内膜和心外膜病变)在 BIP-NS 中最大:结论:UNIP-HNS 和 BIP-NS 均可进行针对厚心肌的较长时间消融(30 W)。由于会产生跨壁病变和/或深入心肌壁的病变,如果能将两个消融导管放置在目标的两侧,则 BIP-NS 更为可取。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
期刊最新文献
Contribution of Continuous Intravenous Lidocaine in Managing Congenital Long QT Syndrome with 2:1 Atrioventricular Block. Left internal jugular vein approach to right atrial appendage base implantation of the Aveir AR leadless pacemaker. Appropriate implantable cardioverter-defibrillator therapy triggered by heat stroke. Lesion characteristics of long application time ablation using unipolar half-normal saline irrigation and bipolar normal saline irrigation. Inadvertent higher rate atrial pacing after dual chamber pacemaker implantation - What is the underlying mechanism?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1