{"title":"Analytical interference on measurement of immunoglobulins in monoclonal gammopathy.","authors":"Anders Oest, Maja Boe, Marianne Christina Harbo Mosgaard, Jeanette Elgaard, Simon Lykkeboe, Paw Jensen, Henrik Gregersen, Stine Linding Andersen, Aase Handberg, Stine Krogh Venø","doi":"10.1080/00365513.2024.2429081","DOIUrl":null,"url":null,"abstract":"<p><p>Monoclonal gammopathy has been reported to interfere with several laboratory measurement results. We investigated potential interference in monoclonal gammopathy on immunoglobulin A (IgA), immunoglobulin G (IgG), and immunoglobulin M (IgM) concentrations using three different routine chemistry instruments: Alinity (Abbott Laboratories), Cobas 8000 (Roche Diagnostics) and Optilite (Binding Site) at the Department of Clinical Biochemistry, Aalborg University Hospital, Denmark. Blood samples collected from 216 patients with known monoclonal gammopathy were analyzed on Alinity, Cobas and Optilite. Diagnoses were ascertained from clinical records. Scatter plots with Passing-Bablok regression were used to investigate associations between concentrations of IgA, IgG and IgM measured with each of the different instruments. Furthermore, comparison of IgG analyses on Alinity, Optilite and Cobas according to monoclonal IgM concentration was explored with Bland-Altman plots. A total of 81 patients were identified with IgM type monoclonal gammopathy and 8 of these patients (10%) had analytical interference as reflected by more than 25% decrease in the level of IgG measured on Alinity as compared to Optilite and Cobas. All blood samples with interference on IgG measurement using Alinity were from patients with lymphoplasmacytic lymphoma/Waldenströms macroglobulinemia and all of them had monoclonal IgM concentrations above 10 g/L. This study identified a source of interference from IgM monoclonal gammopathy on IgG measurement performed using Alinity. The interferences caused falsely low results of IgG which is important to recognize to ensure proper patient management.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-8"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2429081","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Monoclonal gammopathy has been reported to interfere with several laboratory measurement results. We investigated potential interference in monoclonal gammopathy on immunoglobulin A (IgA), immunoglobulin G (IgG), and immunoglobulin M (IgM) concentrations using three different routine chemistry instruments: Alinity (Abbott Laboratories), Cobas 8000 (Roche Diagnostics) and Optilite (Binding Site) at the Department of Clinical Biochemistry, Aalborg University Hospital, Denmark. Blood samples collected from 216 patients with known monoclonal gammopathy were analyzed on Alinity, Cobas and Optilite. Diagnoses were ascertained from clinical records. Scatter plots with Passing-Bablok regression were used to investigate associations between concentrations of IgA, IgG and IgM measured with each of the different instruments. Furthermore, comparison of IgG analyses on Alinity, Optilite and Cobas according to monoclonal IgM concentration was explored with Bland-Altman plots. A total of 81 patients were identified with IgM type monoclonal gammopathy and 8 of these patients (10%) had analytical interference as reflected by more than 25% decrease in the level of IgG measured on Alinity as compared to Optilite and Cobas. All blood samples with interference on IgG measurement using Alinity were from patients with lymphoplasmacytic lymphoma/Waldenströms macroglobulinemia and all of them had monoclonal IgM concentrations above 10 g/L. This study identified a source of interference from IgM monoclonal gammopathy on IgG measurement performed using Alinity. The interferences caused falsely low results of IgG which is important to recognize to ensure proper patient management.
期刊介绍:
The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry.
The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.