Analytical interference on measurement of immunoglobulins in monoclonal gammopathy.

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2024-11-16 DOI:10.1080/00365513.2024.2429081
Anders Oest, Maja Boe, Marianne Christina Harbo Mosgaard, Jeanette Elgaard, Simon Lykkeboe, Paw Jensen, Henrik Gregersen, Stine Linding Andersen, Aase Handberg, Stine Krogh Venø
{"title":"Analytical interference on measurement of immunoglobulins in monoclonal gammopathy.","authors":"Anders Oest, Maja Boe, Marianne Christina Harbo Mosgaard, Jeanette Elgaard, Simon Lykkeboe, Paw Jensen, Henrik Gregersen, Stine Linding Andersen, Aase Handberg, Stine Krogh Venø","doi":"10.1080/00365513.2024.2429081","DOIUrl":null,"url":null,"abstract":"<p><p>Monoclonal gammopathy has been reported to interfere with several laboratory measurement results. We investigated potential interference in monoclonal gammopathy on immunoglobulin A (IgA), immunoglobulin G (IgG), and immunoglobulin M (IgM) concentrations using three different routine chemistry instruments: Alinity (Abbott Laboratories), Cobas 8000 (Roche Diagnostics) and Optilite (Binding Site) at the Department of Clinical Biochemistry, Aalborg University Hospital, Denmark. Blood samples collected from 216 patients with known monoclonal gammopathy were analyzed on Alinity, Cobas and Optilite. Diagnoses were ascertained from clinical records. Scatter plots with Passing-Bablok regression were used to investigate associations between concentrations of IgA, IgG and IgM measured with each of the different instruments. Furthermore, comparison of IgG analyses on Alinity, Optilite and Cobas according to monoclonal IgM concentration was explored with Bland-Altman plots. A total of 81 patients were identified with IgM type monoclonal gammopathy and 8 of these patients (10%) had analytical interference as reflected by more than 25% decrease in the level of IgG measured on Alinity as compared to Optilite and Cobas. All blood samples with interference on IgG measurement using Alinity were from patients with lymphoplasmacytic lymphoma/Waldenströms macroglobulinemia and all of them had monoclonal IgM concentrations above 10 g/L. This study identified a source of interference from IgM monoclonal gammopathy on IgG measurement performed using Alinity. The interferences caused falsely low results of IgG which is important to recognize to ensure proper patient management.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-8"},"PeriodicalIF":1.3000,"publicationDate":"2024-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2429081","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Monoclonal gammopathy has been reported to interfere with several laboratory measurement results. We investigated potential interference in monoclonal gammopathy on immunoglobulin A (IgA), immunoglobulin G (IgG), and immunoglobulin M (IgM) concentrations using three different routine chemistry instruments: Alinity (Abbott Laboratories), Cobas 8000 (Roche Diagnostics) and Optilite (Binding Site) at the Department of Clinical Biochemistry, Aalborg University Hospital, Denmark. Blood samples collected from 216 patients with known monoclonal gammopathy were analyzed on Alinity, Cobas and Optilite. Diagnoses were ascertained from clinical records. Scatter plots with Passing-Bablok regression were used to investigate associations between concentrations of IgA, IgG and IgM measured with each of the different instruments. Furthermore, comparison of IgG analyses on Alinity, Optilite and Cobas according to monoclonal IgM concentration was explored with Bland-Altman plots. A total of 81 patients were identified with IgM type monoclonal gammopathy and 8 of these patients (10%) had analytical interference as reflected by more than 25% decrease in the level of IgG measured on Alinity as compared to Optilite and Cobas. All blood samples with interference on IgG measurement using Alinity were from patients with lymphoplasmacytic lymphoma/Waldenströms macroglobulinemia and all of them had monoclonal IgM concentrations above 10 g/L. This study identified a source of interference from IgM monoclonal gammopathy on IgG measurement performed using Alinity. The interferences caused falsely low results of IgG which is important to recognize to ensure proper patient management.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单克隆抗体病中免疫球蛋白测量的分析干扰。
据报道,单克隆抗体可干扰多种实验室测量结果。我们使用三种不同的常规化学仪器调查了单克隆抗体对免疫球蛋白 A (IgA)、免疫球蛋白 G (IgG) 和免疫球蛋白 M (IgM) 浓度的潜在干扰:丹麦奥尔堡大学医院临床生物化学系使用三种不同的常规化学仪器:Alinity(雅培实验室)、Cobas 8000(罗氏诊断公司)和 Optilite(Binding Site)。从 216 名已知患有单克隆丙种球蛋白病的患者身上采集的血液样本在 Alinity、Cobas 和 Optilite 上进行了分析。诊断结果来自临床记录。使用 Passing-Bablok 回归法绘制散点图,研究不同仪器测量的 IgA、IgG 和 IgM 浓度之间的关联。此外,还利用Bland-Altman图对Alinity、Optilite和Cobas上的IgG分析结果与单克隆IgM浓度进行了比较。共有 81 名患者被确诊为 IgM 型单克隆丙种球蛋白病,其中有 8 名患者(10%)受到了分析干扰,表现为 Alinity 与 Optilite 和 Cobas 相比所测得的 IgG 水平下降了 25% 以上。使用 Alinity 检测 IgG 时受到干扰的所有血液样本均来自淋巴浆细胞性淋巴瘤/瓦尔登斯特罗姆巨球蛋白血症患者,他们的单克隆 IgM 浓度均超过 10 克/升。这项研究确定了 IgM 单克隆性腺病对使用 Alinity 进行的 IgG 测量的干扰源。这种干扰会导致 IgG 检测结果偏低,因此必须认识到这一点,以确保对患者进行正确的管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
期刊最新文献
Analytical interference on measurement of immunoglobulins in monoclonal gammopathy. FlowDiff: a simple, flow cytometry-based approach for performing a leukocyte differential count. Reference intervals for 23 common biochemical parameters during pregnancy and the first six postpartum months. Prevalence of monoclonal proteins in patients with isolated hypogammaglobulinemia on serum protein electrophoresis. Challenges of preanalytical variables in erythrocyte sedimentation rate: a CUBE 30 touch evaluation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1