Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard.

IF 1.2 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL Pakistan Journal of Medical Sciences Pub Date : 2024-11-01 DOI:10.12669/pjms.40.10.8575
Tahir Ghaffar, Shaista Kanwal, Azizul Hasan Aamir, Nizamud Din
{"title":"Diagnostic accuracy of ultrasonography and 99m-Technetium Sestamibi scintigraphy for the preoperative localization of Parathyroid Adenoma keeping histopathological findings as reference standard.","authors":"Tahir Ghaffar, Shaista Kanwal, Azizul Hasan Aamir, Nizamud Din","doi":"10.12669/pjms.40.10.8575","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the diagnostic accuracy of Ultrasound (US) and 99m-Tc Sestamibi scan in patients with primary hyperparathyroidism (PHPT) for the localization of parathyroid adenoma before surgery keeping Parathyroid histopathology as reference standard.</p><p><strong>Method: </strong>This three years retrospective study was performed in the Department of Endocrinology, Hayatabad Medical Complex, Peshawar. Patients with PHPT who underwent parathyroidectomy from July 2019 to June 2022 were included in the study. Information relating to localization studies prior to surgical management like US and 99m-Tc Sestamibi scan was documented. These imaging findings were subsequently compared with the findings of parathyroid surgery and histopathology results which were taken as reference standard.</p><p><strong>Results: </strong>The sensitivity, positive predictive value (PPV) and overall accuracy of US for the preoperative localization of parathyroid adenoma was 77%, 95.7% and 75%, respectively. Whereas the sensitivity, PPV and accuracy of 99m-Tc Sestamibi scintigraphy was 89.5%, 95% and 86% respectively.</p><p><strong>Conclusion: </strong>Ultrasound despite its cost effectiveness has a lower sensitivity compared to 99m-Tc Sestamibi scintigraphy. Similarly, the sensitivity and overall accuracy of US and 99m-Tc Sestamibi scan when taken in combination is higher compared to either modality. It is thus recommended that the combination of these modalities should be employed to localize the adenomas accurately for surgery of the parathyroid gland for a better outcome.</p>","PeriodicalId":19958,"journal":{"name":"Pakistan Journal of Medical Sciences","volume":"40 10","pages":"2405-2409"},"PeriodicalIF":1.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11568711/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Journal of Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12669/pjms.40.10.8575","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To determine the diagnostic accuracy of Ultrasound (US) and 99m-Tc Sestamibi scan in patients with primary hyperparathyroidism (PHPT) for the localization of parathyroid adenoma before surgery keeping Parathyroid histopathology as reference standard.

Method: This three years retrospective study was performed in the Department of Endocrinology, Hayatabad Medical Complex, Peshawar. Patients with PHPT who underwent parathyroidectomy from July 2019 to June 2022 were included in the study. Information relating to localization studies prior to surgical management like US and 99m-Tc Sestamibi scan was documented. These imaging findings were subsequently compared with the findings of parathyroid surgery and histopathology results which were taken as reference standard.

Results: The sensitivity, positive predictive value (PPV) and overall accuracy of US for the preoperative localization of parathyroid adenoma was 77%, 95.7% and 75%, respectively. Whereas the sensitivity, PPV and accuracy of 99m-Tc Sestamibi scintigraphy was 89.5%, 95% and 86% respectively.

Conclusion: Ultrasound despite its cost effectiveness has a lower sensitivity compared to 99m-Tc Sestamibi scintigraphy. Similarly, the sensitivity and overall accuracy of US and 99m-Tc Sestamibi scan when taken in combination is higher compared to either modality. It is thus recommended that the combination of these modalities should be employed to localize the adenomas accurately for surgery of the parathyroid gland for a better outcome.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
以组织病理学结果为参考标准,超声波和 99m-锝 Sestamibi 闪烁扫描对甲状旁腺腺瘤术前定位的诊断准确性。
目的以甲状旁腺组织病理学为参考标准,确定原发性甲状旁腺功能亢进症(PHPT)患者在手术前使用超声波(US)和99m-Tc铯同位素扫描定位甲状旁腺腺瘤的诊断准确性:这项为期三年的回顾性研究在白沙瓦哈亚塔巴德医疗中心内分泌科进行。研究纳入了2019年7月至2022年6月期间接受甲状旁腺切除术的PHPT患者。研究记录了手术治疗前的定位检查信息,如 US 和 99m-Tc Sestamibi 扫描。随后,将这些成像结果与作为参考标准的甲状旁腺手术结果和组织病理学结果进行比较:甲状旁腺腺瘤术前定位的敏感性、阳性预测值(PPV)和总体准确性分别为77%、95.7%和75%。而99m-Tc铯同位素闪烁扫描的敏感性、PPV和准确性分别为89.5%、95%和86%:结论:与 99m-Tc 塞斯他嘧啶闪烁照相术相比,超声波尽管具有成本效益,但灵敏度较低。同样,超声和 99m锝 塞斯塔米比扫描联合使用时,其灵敏度和总体准确性要高于任何一种方式。因此,建议在进行甲状旁腺手术时结合使用这些方法来准确定位腺瘤,以获得更好的疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pakistan Journal of Medical Sciences
Pakistan Journal of Medical Sciences 医学-医学:内科
CiteScore
4.10
自引率
9.10%
发文量
363
审稿时长
3-6 weeks
期刊介绍: It is a peer reviewed medical journal published regularly since 1984. It was previously known as quarterly "SPECIALIST" till December 31st 1999. It publishes original research articles, review articles, current practices, short communications & case reports. It attracts manuscripts not only from within Pakistan but also from over fifty countries from abroad. Copies of PJMS are sent to all the import medical libraries all over Pakistan and overseas particularly in South East Asia and Asia Pacific besides WHO EMRO Region countries. Eminent members of the medical profession at home and abroad regularly contribute their write-ups, manuscripts in our publications. We pursue an independent editorial policy, which allows an opportunity to the healthcare professionals to express their views without any fear or favour. That is why many opinion makers among the medical and pharmaceutical profession use this publication to communicate their viewpoint.
期刊最新文献
A day of shame. A comparison of the therapeutic efficacy of Tenofovir Disoproxil Fumarate and Entecavir in patients with chronic Hepatitis-B. Burden of congenital and hereditary anomalies and their epidemiological attributes in the pediatric and adult population of Peshawar valley, Pakistan. Clinical efficacy of Azadirachta indica based herbal mouthwash in treating the hypersensitivity of teeth. Clinical whole Exome Sequencing Reveals Novel Homozygous Missense Variant in the PMPCA Gene causing Autosomal Recessive Spinocerebellar Ataxia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1