Diagnostic accuracy of point-of-care lung ultrasound for community-acquired pneumonia in children in ambulatory settings: A systematic review and meta-analysis.

IF 0.8 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Ultrasound Pub Date : 2024-10-29 DOI:10.1177/1742271X241289726
Helena Hughes-Davies, Umasha Ukwatte, Thomas R Fanshawe, Nia Roberts, Philip J Turner, Gail N Hayward, Chris Bird
{"title":"Diagnostic accuracy of point-of-care lung ultrasound for community-acquired pneumonia in children in ambulatory settings: A systematic review and meta-analysis.","authors":"Helena Hughes-Davies, Umasha Ukwatte, Thomas R Fanshawe, Nia Roberts, Philip J Turner, Gail N Hayward, Chris Bird","doi":"10.1177/1742271X241289726","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To perform a systematic review of the diagnostic accuracy of point-of-care lung ultrasound, compared to chest radiography, in children and young people (0-21 years) who present to ambulatory settings with suspected community-acquired pneumonia.</p><p><strong>Methods: </strong>Registration: Prospero June 2021 CRD42021260552. Electronic searching performed on Medline, Embase, CINAHL and Science Citation Index from inception to 20 June 2023. Two researchers independently screened titles, abstracts, and full texts for study selection. Risk of bias was assessed using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) tool. Meta-analysis of included studies.</p><p><strong>Results: </strong>The six studies included in this systematic review described point-of-care lung ultrasound performed primarily by paediatric emergency medicine clinicians on a total of 1099 paediatric patients, with a reference standard of chest radiography or chest radiography with clinical findings. The majority of included studies lacked clarity on training for the index test with potential bias around flow and timing of testing. Meta-analysis of the combined results of the included six studies calculated a pooled sensitivity of 90.9% (95% CI [85.5%, 94.4%]) and pooled specificity of 80.7% (95% CI [63.6%, 91.0%]).</p><p><strong>Conclusions: </strong>Point-of-care lung ultrasound has high sensitivity but lower specificity to diagnose acute pneumonia in children. Further research is needed which overcomes issues around training in point-of-care lung ultrasound, study design and reliability of the reference test (chest radiography) to better evidence the role of point-of-care lung ultrasound in diagnosing pneumonia in children in ambulatory and resource-limited settings.</p>","PeriodicalId":23440,"journal":{"name":"Ultrasound","volume":" ","pages":"1742271X241289726"},"PeriodicalIF":0.8000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563508/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1742271X241289726","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: To perform a systematic review of the diagnostic accuracy of point-of-care lung ultrasound, compared to chest radiography, in children and young people (0-21 years) who present to ambulatory settings with suspected community-acquired pneumonia.

Methods: Registration: Prospero June 2021 CRD42021260552. Electronic searching performed on Medline, Embase, CINAHL and Science Citation Index from inception to 20 June 2023. Two researchers independently screened titles, abstracts, and full texts for study selection. Risk of bias was assessed using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) tool. Meta-analysis of included studies.

Results: The six studies included in this systematic review described point-of-care lung ultrasound performed primarily by paediatric emergency medicine clinicians on a total of 1099 paediatric patients, with a reference standard of chest radiography or chest radiography with clinical findings. The majority of included studies lacked clarity on training for the index test with potential bias around flow and timing of testing. Meta-analysis of the combined results of the included six studies calculated a pooled sensitivity of 90.9% (95% CI [85.5%, 94.4%]) and pooled specificity of 80.7% (95% CI [63.6%, 91.0%]).

Conclusions: Point-of-care lung ultrasound has high sensitivity but lower specificity to diagnose acute pneumonia in children. Further research is needed which overcomes issues around training in point-of-care lung ultrasound, study design and reliability of the reference test (chest radiography) to better evidence the role of point-of-care lung ultrasound in diagnosing pneumonia in children in ambulatory and resource-limited settings.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
门诊儿童社区获得性肺炎护理点肺部超声诊断的准确性:系统回顾和荟萃分析。
内容简介对儿童和青少年(0-21 岁)因疑似社区获得性肺炎而就诊的情况进行系统性回顾,比较护理点肺部超声波与胸部放射摄影的诊断准确性:注册:Prospero 2021 年 6 月 CRD42021260552。在 Medline、Embase、CINAHL 和《科学引文索引》上进行电子检索,检索期从开始至 2023 年 6 月 20 日。两名研究人员独立筛选了研究的标题、摘要和全文。使用诊断准确性研究质量评估工具(QUADAS-2)对偏倚风险进行评估。对纳入的研究进行元分析:本系统综述纳入的六项研究描述了主要由儿科急诊医学临床医生对共计 1099 名儿科患者进行的护理点肺部超声检查,参考标准为胸部放射摄影或胸部放射摄影与临床发现。纳入的大多数研究都没有明确说明指标检测的培训情况,因此在流程和检测时间方面可能存在偏差。对所纳入的六项研究的综合结果进行的 Meta 分析计算得出,汇总灵敏度为 90.9%(95% CI [85.5%,94.4%]),汇总特异度为 80.7%(95% CI [63.6%,91.0%]):结论:护理点肺部超声诊断儿童急性肺炎的灵敏度较高,但特异性较低。为了更好地证明护理点肺部超声波在非卧床和资源有限环境中诊断儿童肺炎的作用,还需要进一步的研究,以克服护理点肺部超声波的培训、研究设计和参考测试(胸部放射摄影)的可靠性等问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultrasound
Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.70
自引率
0.00%
发文量
55
期刊介绍: Ultrasound is the official journal of the British Medical Ultrasound Society (BMUS), a multidisciplinary, charitable society comprising radiologists, obstetricians, sonographers, physicists and veterinarians amongst others.
期刊最新文献
Two case reports of triple ectopic: Literature review of incidence, risk factors and management of recurrent ectopic pregnancy. Beyond the hernia in groin ultrasound. Investigation of artificial intelligence-based clinical decision support system's performance in reducing the fine needle aspiration rate of thyroid nodules: A pilot study. Advanced multimodal ultrasound for pre-operative assessment of skin tumours: A case series. Diagnostic accuracy of strain cervical elastography as a predictor for preterm delivery: A single tertiary care centre study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1