Intelligent protective relaying for the series compensated line with high penetration of wind energy sources

IF 5 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC International Journal of Electrical Power & Energy Systems Pub Date : 2024-11-10 DOI:10.1016/j.ijepes.2024.110362
Subodh Kumar Mohanty , Paresh Kumar Nayak , Pierluigi Siano , Aleena Swetapadma
{"title":"Intelligent protective relaying for the series compensated line with high penetration of wind energy sources","authors":"Subodh Kumar Mohanty ,&nbsp;Paresh Kumar Nayak ,&nbsp;Pierluigi Siano ,&nbsp;Aleena Swetapadma","doi":"10.1016/j.ijepes.2024.110362","DOIUrl":null,"url":null,"abstract":"<div><div>The bulk amount of power generated from the present-day large-scale DFIG-installed wind farms are preferably transmitted to utility grid through series compensated transmission lines. Currently, TCSC compensation is more attractive compared to fixed series compensation due to its numerous technical advantages. However, the nonlinear relationship of the output power verses wind speed and the different operating modes of the DFIG and TCSC cause rapid variation in the line impedance during both normal as well as fault conditions. Consequently, the widely used fixed impedance-based distance relays when used for protection of such lines find limitation. In this paper, a fast discrete S-transform feature-assisted back propagation neural network technique is proposed using the relay end current measurements for effective detection and classification of faults in such crucial transmission lines. The efficacy of the scheme is evaluated on numerous fault and non-fault cases simulated through MATLAB/Simulink on different standard test systems under varying system operating conditions. The results clearly show the superiority of the proposed method in comparision to the existing approaches in terms of its low computational burden, fast fault detection time (&lt; 10 ms) and accuracies (= 100 %) and fast fault classification time (&lt; 10 ms) and accuracies (99.99 %).</div></div>","PeriodicalId":50326,"journal":{"name":"International Journal of Electrical Power & Energy Systems","volume":"163 ","pages":"Article 110362"},"PeriodicalIF":5.0000,"publicationDate":"2024-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Power & Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142061524005854","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The bulk amount of power generated from the present-day large-scale DFIG-installed wind farms are preferably transmitted to utility grid through series compensated transmission lines. Currently, TCSC compensation is more attractive compared to fixed series compensation due to its numerous technical advantages. However, the nonlinear relationship of the output power verses wind speed and the different operating modes of the DFIG and TCSC cause rapid variation in the line impedance during both normal as well as fault conditions. Consequently, the widely used fixed impedance-based distance relays when used for protection of such lines find limitation. In this paper, a fast discrete S-transform feature-assisted back propagation neural network technique is proposed using the relay end current measurements for effective detection and classification of faults in such crucial transmission lines. The efficacy of the scheme is evaluated on numerous fault and non-fault cases simulated through MATLAB/Simulink on different standard test systems under varying system operating conditions. The results clearly show the superiority of the proposed method in comparision to the existing approaches in terms of its low computational burden, fast fault detection time (< 10 ms) and accuracies (= 100 %) and fast fault classification time (< 10 ms) and accuracies (99.99 %).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高风能渗透率串联补偿线路的智能继电保护系统
目前,安装了双馈变流器的大型风力发电场所产生的大量电力最好通过串联补偿输电线路输送到公用电网。目前,与固定串联补偿相比,TCSC 补偿因其众多技术优势而更具吸引力。然而,输出功率与风速的非线性关系,以及 DFIG 和 TCSC 的不同运行模式,都会导致线路阻抗在正常和故障情况下快速变化。因此,广泛使用的基于固定阻抗的距离继电器在用于保护此类线路时受到了限制。本文提出了一种快速离散 S 变换特征辅助反向传播神经网络技术,利用继电器末端电流测量值对此类关键输电线路进行有效的故障检测和分类。在不同的系统运行条件下,通过 MATLAB/Simulink 在不同的标准测试系统上模拟了大量故障和非故障案例,对该方案的功效进行了评估。结果清楚地表明,与现有方法相比,所提出的方法具有计算负担低、故障检测时间短(10 毫秒)、准确率高(100%)、故障分类时间短(10 毫秒)、准确率高(99.99%)等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Electrical Power & Energy Systems
International Journal of Electrical Power & Energy Systems 工程技术-工程:电子与电气
CiteScore
12.10
自引率
17.30%
发文量
1022
审稿时长
51 days
期刊介绍: The journal covers theoretical developments in electrical power and energy systems and their applications. The coverage embraces: generation and network planning; reliability; long and short term operation; expert systems; neural networks; object oriented systems; system control centres; database and information systems; stock and parameter estimation; system security and adequacy; network theory, modelling and computation; small and large system dynamics; dynamic model identification; on-line control including load and switching control; protection; distribution systems; energy economics; impact of non-conventional systems; and man-machine interfaces. As well as original research papers, the journal publishes short contributions, book reviews and conference reports. All papers are peer-reviewed by at least two referees.
期刊最新文献
Microgrid energy management strategy considering source-load forecast error A dimension-enhanced residual multi-scale attention framework for identifying anomalous waveforms of fault recorders Grid structure optimization using slow coherency theory and holomorphic embedding method Two-stage multi-objective optimal dispatch of hybrid power generation system for ramp stress mitigation A fast, simple and local protection scheme for fault detection and classification during power swings based on differential current component
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1