Performance assessment of new Poisoning Mortality Score and PGI score for predicting mortality in patients with acute aluminum phosphide poisoning.

Ghada N El-Sarnagawy, Amira A Abdelnoor, Mona M Ghonem
{"title":"Performance assessment of new Poisoning Mortality Score and PGI score for predicting mortality in patients with acute aluminum phosphide poisoning.","authors":"Ghada N El-Sarnagawy, Amira A Abdelnoor, Mona M Ghonem","doi":"10.1177/09603271241302208","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Until now, no definite standardized method has been used to promptly assess the severity and outcome of acute aluminum phosphide (ALP) poisoning. The current study aimed to evaluate the performance of the new Poisoning Mortality Score (PMS) and PGI score for predicting mortality in acute ALP-poisoned patients, highlighting the accuracy of new PMS components.</p><p><strong>Patients and methods: </strong>A 2-year cross-sectional study was conducted on ALP-poisoned patients admitted to Tanta University Poison Control Centre from April 2021 to March 2023. Socio-demographics, poisoning data, and initial vital signs were recorded. Additionally, new PMS and PGI scores were calculated on admission. Patients were categorized according to the mortality outcome into survivors and nonsurvivors.</p><p><strong>Results: </strong>Out of 160 included ALP poisoned patients, mortality was recorded in 112 (70%) patients. The nonsurvivors had significantly higher median PGI and new PMS values than survivors. New PMS, vital signs component of new PMS, and PGI conveyed good discriminatory power for predicting mortality (AUC = 0.883, 0.873, and 0.817, respectively). Although the new PMS outperformed PGI in all predictive metrics, no significant difference in AUCs was observed between the new PMS and its vital signs component.</p><p><strong>Conclusion: </strong>The new PMS vital signs component is closely aligned with the new PMS. Thus, it can be used as a valid, comprehensive, and practical tool to substitute the whole score calculation for rapid ALP-poisoned patient assessment to enhance emergency clinical decision-making.</p>","PeriodicalId":94029,"journal":{"name":"Human & experimental toxicology","volume":"43 ","pages":"9603271241302208"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human & experimental toxicology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/09603271241302208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Until now, no definite standardized method has been used to promptly assess the severity and outcome of acute aluminum phosphide (ALP) poisoning. The current study aimed to evaluate the performance of the new Poisoning Mortality Score (PMS) and PGI score for predicting mortality in acute ALP-poisoned patients, highlighting the accuracy of new PMS components.

Patients and methods: A 2-year cross-sectional study was conducted on ALP-poisoned patients admitted to Tanta University Poison Control Centre from April 2021 to March 2023. Socio-demographics, poisoning data, and initial vital signs were recorded. Additionally, new PMS and PGI scores were calculated on admission. Patients were categorized according to the mortality outcome into survivors and nonsurvivors.

Results: Out of 160 included ALP poisoned patients, mortality was recorded in 112 (70%) patients. The nonsurvivors had significantly higher median PGI and new PMS values than survivors. New PMS, vital signs component of new PMS, and PGI conveyed good discriminatory power for predicting mortality (AUC = 0.883, 0.873, and 0.817, respectively). Although the new PMS outperformed PGI in all predictive metrics, no significant difference in AUCs was observed between the new PMS and its vital signs component.

Conclusion: The new PMS vital signs component is closely aligned with the new PMS. Thus, it can be used as a valid, comprehensive, and practical tool to substitute the whole score calculation for rapid ALP-poisoned patient assessment to enhance emergency clinical decision-making.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
预测急性磷化铝中毒患者死亡率的新中毒死亡率评分和 PGI 评分的性能评估。
背景:迄今为止,尚无明确的标准化方法用于及时评估急性磷化铝(ALP)中毒的严重程度和预后。本研究旨在评估新的中毒死亡率评分(PMS)和 PGI 评分在预测急性 ALP 中毒患者死亡率方面的表现,强调新的 PMS 成分的准确性:对 2021 年 4 月至 2023 年 3 月期间坦塔大学中毒控制中心收治的 ALP 中毒患者进行了为期两年的横断面研究。研究记录了社会人口统计学、中毒数据和初始生命体征。此外,还计算了入院时新的 PMS 和 PGI 分数。根据死亡结果将患者分为幸存者和非幸存者:在 160 名 ALP 中毒患者中,有 112 人(70%)死亡。非存活者的 PGI 和新 PMS 中位值明显高于存活者。新PMS、新PMS的生命体征部分和PGI在预测死亡率方面具有良好的鉴别力(AUC分别为0.883、0.873和0.817)。虽然新 PMS 在所有预测指标上都优于 PGI,但新 PMS 与其生命体征组件之间的 AUC 并无显著差异:结论:新 PMS 生命体征部分与新 PMS 非常吻合。结论:新的 PMS 生命体征部分与新的 PMS 非常一致,因此,它可以作为一种有效、全面和实用的工具,替代 ALP 中毒患者快速评估的整体评分计算,以加强急诊临床决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Potential induction of hyperkeratosis in rats' cervi by gentamicin via induction of oxidative stress, inflammation and apoptosis. Gpnmb silencing protects against hyperoxia-induced acute lung injury by inhibition of mitochondrial-mediated apoptosis. Evaluation of Cd-induced cytotoxicity in primary human keratinocytes. The effect of melatonin on capecitabine-induced hepatic and renal toxicity in rats. Evaluation of antioxidant properties and cytotoxicity of brown algae (nizamuddinia zanardinii) in uterine (hela) and pancreatic cancer cell lines (paca-2).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1