The intersubject reliability of cortical auditory evoked potential (CAEP) in pediatric cochlear implant recipients: comparisons between acoustic and electrical stimulations.
Rosninda Abdullah, Nashrah Maamor, Mohd Normani Zakaria, Nik Adilah Nik Othman, Basyariatul Fathi Othman, Noor Alaudin Abdul Wahab
{"title":"The intersubject reliability of cortical auditory evoked potential (CAEP) in pediatric cochlear implant recipients: comparisons between acoustic and electrical stimulations.","authors":"Rosninda Abdullah, Nashrah Maamor, Mohd Normani Zakaria, Nik Adilah Nik Othman, Basyariatul Fathi Othman, Noor Alaudin Abdul Wahab","doi":"10.1007/s00405-024-09080-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the intersubject reliability of cortical auditory evoked potential (CAEP) elicited by acoustic and electrical stimulations in pediatric cochlear implant (CI) recipients.</p><p><strong>Methods: </strong>Twenty-two MED-EL CI recipients (aged 13-93 months) participated in this study. The acoustic CAEP (aCAEP) waveforms were elicited using four speech stimuli (/ba/, /m/, /g/, and /t/) presented at 65 dB SPL in a free-field condition. The electrical CAEP (eCAEP) responses were obtained by presenting electrical pulses through apical, medial, and basal electrodes. The aCAEP and eCAEP data (n = 28 ears) were analyzed using coefficient of variation (CV) and other appropriate statistics.</p><p><strong>Results: </strong>P1, N1, and P2 peaks were observed in most of the children (92.9% response rate). The CV values were smaller for the latency metric (13.6-34.2%) relative to the amplitude metric (51.3-92.4%), and the differences were statistically significant (p < 0.001). The aCAEP yielded smaller mean CV values than the eCAEP (for both latency and amplitude measures), and the mean CV value for the aCAEP (15.6%) was found to be statistically different from that of the eCAEP (31.0%) for the P1 latency (p = 0.001).</p><p><strong>Conclusion: </strong>This study is the first to report the intersubject reliability of aCAEP and eCAEP in pediatric CI recipients. Overall, CAEP latencies were found to be more reliable than CAEP amplitudes, and the aCAEP testing demonstrated higher intersubject reliability compared to the eCAEP assessment. The present study's findings can be beneficial for researchers and clinicians in documenting CAEP in children who use CI.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00405-024-09080-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To compare the intersubject reliability of cortical auditory evoked potential (CAEP) elicited by acoustic and electrical stimulations in pediatric cochlear implant (CI) recipients.
Methods: Twenty-two MED-EL CI recipients (aged 13-93 months) participated in this study. The acoustic CAEP (aCAEP) waveforms were elicited using four speech stimuli (/ba/, /m/, /g/, and /t/) presented at 65 dB SPL in a free-field condition. The electrical CAEP (eCAEP) responses were obtained by presenting electrical pulses through apical, medial, and basal electrodes. The aCAEP and eCAEP data (n = 28 ears) were analyzed using coefficient of variation (CV) and other appropriate statistics.
Results: P1, N1, and P2 peaks were observed in most of the children (92.9% response rate). The CV values were smaller for the latency metric (13.6-34.2%) relative to the amplitude metric (51.3-92.4%), and the differences were statistically significant (p < 0.001). The aCAEP yielded smaller mean CV values than the eCAEP (for both latency and amplitude measures), and the mean CV value for the aCAEP (15.6%) was found to be statistically different from that of the eCAEP (31.0%) for the P1 latency (p = 0.001).
Conclusion: This study is the first to report the intersubject reliability of aCAEP and eCAEP in pediatric CI recipients. Overall, CAEP latencies were found to be more reliable than CAEP amplitudes, and the aCAEP testing demonstrated higher intersubject reliability compared to the eCAEP assessment. The present study's findings can be beneficial for researchers and clinicians in documenting CAEP in children who use CI.
期刊介绍:
Official Journal of
European Union of Medical Specialists – ORL Section and Board
Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery
"European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level.
European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.