The influence of age and hearing loss on thresholds measured using the TFS-AF test.

IF 1.8 3区 医学 Q2 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY International Journal of Audiology Pub Date : 2024-11-22 DOI:10.1080/14992027.2024.2427252
Emanuele Perugia, Melanie Lough, Michael A Stone
{"title":"The influence of age and hearing loss on thresholds measured using the TFS-AF test.","authors":"Emanuele Perugia, Melanie Lough, Michael A Stone","doi":"10.1080/14992027.2024.2427252","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The upper limit of sensitivity to binaural temporal fine structure (TFS) is around 1400 Hz. Higher values have been reported when keeping interaural phase differences fixed and varying the frequency adaptively, as in the adaptive-frequency TFS test [TFS-AF, Füllgrabe et al., Int J Audiol, 56, 926-935]. The probability of TFS-AF thresholds exceeding 1400 Hz, and the influence of age and hearing threshold were assessed.</p><p><strong>Design and study sample: </strong>TFS-AF thresholds from 277 participants across five studies were re-analysed as a function of Age, low-frequency pure-tone average threshold (PTL; 250, 500, 1000 and 2000 Hz), and high-frequency pure-tone average threshold (PTH; 6000 and 8000 Hz). The 95% confidence intervals on TFS-AF thresholds were computed. The effects of Age and Hearing threshold on the TFS-AF thresholds were assessed using a multiple-regression model.</p><p><strong>Results: </strong>The bootstrapped 95% confidence interval for this dataset around the median was 1030 to 1122 Hz, similar to that predicted by Monte Carlo simulation. This range was affected by Age and PTL. Regression modelling showed that the occurrence rate of TFS-AF thresholds exceeding 1400 Hz increased with younger Age and better PTL.</p><p><strong>Conclusions: </strong>TFS-AF thresholds exceeding 1400 Hz are more likely for lower ages and better hearing thresholds.</p>","PeriodicalId":13759,"journal":{"name":"International Journal of Audiology","volume":" ","pages":"1-9"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Audiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14992027.2024.2427252","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The upper limit of sensitivity to binaural temporal fine structure (TFS) is around 1400 Hz. Higher values have been reported when keeping interaural phase differences fixed and varying the frequency adaptively, as in the adaptive-frequency TFS test [TFS-AF, Füllgrabe et al., Int J Audiol, 56, 926-935]. The probability of TFS-AF thresholds exceeding 1400 Hz, and the influence of age and hearing threshold were assessed.

Design and study sample: TFS-AF thresholds from 277 participants across five studies were re-analysed as a function of Age, low-frequency pure-tone average threshold (PTL; 250, 500, 1000 and 2000 Hz), and high-frequency pure-tone average threshold (PTH; 6000 and 8000 Hz). The 95% confidence intervals on TFS-AF thresholds were computed. The effects of Age and Hearing threshold on the TFS-AF thresholds were assessed using a multiple-regression model.

Results: The bootstrapped 95% confidence interval for this dataset around the median was 1030 to 1122 Hz, similar to that predicted by Monte Carlo simulation. This range was affected by Age and PTL. Regression modelling showed that the occurrence rate of TFS-AF thresholds exceeding 1400 Hz increased with younger Age and better PTL.

Conclusions: TFS-AF thresholds exceeding 1400 Hz are more likely for lower ages and better hearing thresholds.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
年龄和听力损失对使用 TFS-AF 测试测量的阈值的影响。
目的:双耳时间精细结构(TFS)的灵敏度上限约为 1400 赫兹。据报道,在保持耳间相位差固定并自适应改变频率的情况下(如自适应频率 TFS 测试 [TFS-AF, Füllgrabe 等人,Int J Audiol, 56, 926-935]),该值会更高。研究评估了 TFS-AF 阈值超过 1400 Hz 的概率,以及年龄和听力阈值的影响:重新分析了五项研究中 277 名参与者的 TFS-AF 阈值与年龄、低频纯音平均阈值(PTL;250、500、1000 和 2000 Hz)和高频纯音平均阈值(PTH;6000 和 8000 Hz)的关系。计算了TFS-AF阈值的95%置信区间。使用多元回归模型评估了年龄和听阈对 TFS-AF 阈值的影响:该数据集围绕中位数的自引导 95% 置信区间为 1030 至 1122 Hz,与蒙特卡罗模拟预测的相似。这一范围受到年龄和 PTL 的影响。回归模型显示,TFS-AF阈值超过 1400 Hz 的发生率随着年龄的增长和 PTL 的改善而增加:结论:年龄越小、听力阈值越高,TFS-AF阈值超过 1400 Hz 的可能性越大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Audiology
International Journal of Audiology 医学-耳鼻喉科学
CiteScore
4.90
自引率
14.80%
发文量
133
审稿时长
4-8 weeks
期刊介绍: International Journal of Audiology is committed to furthering development of a scientifically robust evidence base for audiology. The journal is published by the British Society of Audiology, the International Society of Audiology and the Nordic Audiological Society.
期刊最新文献
The influence of age and hearing loss on thresholds measured using the TFS-AF test. Simplified frequency selectivity measure as a potential candidate for hearing screening: changes with masker level and test-retest reliability of self-administered testing. "Can physical activity reduce the risk of having tinnitus?" Risky leisure noise exposure during the transition to adulthood and the impact of major life events - results of the OHRKAN cohort study. Applications of automatic speech recognition and text-to-speech technologies for hearing assessment: a scoping review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1