The systemic and local interactions related to titanium implant corrosion and hypersensitivity reactions: a narrative review of the literature.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2024-11-22 DOI:10.1186/s40729-024-00578-3
Alexander Swalsky, Sammy S Noumbissi, Thomas G Wiedemann
{"title":"The systemic and local interactions related to titanium implant corrosion and hypersensitivity reactions: a narrative review of the literature.","authors":"Alexander Swalsky, Sammy S Noumbissi, Thomas G Wiedemann","doi":"10.1186/s40729-024-00578-3","DOIUrl":null,"url":null,"abstract":"<p><p>Both commercially pure titanium and titanium alloys are established biomaterials for implantation in bone and are widely used today in dentistry. Titanium particulates have been shown in some patient clusters to induce cellular immune mediators responsible for type I and IV hypersensitivity reactions, causing amplified corrosion, osteolysis, and increased odds of implant failure. Systemically, titanium particles were found to affect varying organ tissues and cause potentially harmful effects. In vivo and vitro studies have shown that titanium dental implant corrosion can be induced by factors relating to bio-tribocorrosion. In this literature review, the consequences of titanium implant corrosion and particulate dissemination are discussed and later juxtaposed against a promising novel implant material, zirconia. Zirconia offers characteristics similar to titanium along with additional advantages such as being non-corrosive and having a lower propensity for inducing immune responses. From the mounting evidence discussed in this article, metal allergy testing would be advantageous for choosing an appropriate implant material to minimize potential adverse effects on cellular functions of local and diffuse tissues. Objective: This literature review aims to elucidate and describe mechanisms in which titanium implants may become corroded and induce cellular aberrations both locally and systemically in vivo. Implications of this study provide supportive evidence regarding the selection of appropriate biomaterials for implant patients susceptible to mounting a hypersensitivity reaction to titanium.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"10 1","pages":"58"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11584828/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-024-00578-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Both commercially pure titanium and titanium alloys are established biomaterials for implantation in bone and are widely used today in dentistry. Titanium particulates have been shown in some patient clusters to induce cellular immune mediators responsible for type I and IV hypersensitivity reactions, causing amplified corrosion, osteolysis, and increased odds of implant failure. Systemically, titanium particles were found to affect varying organ tissues and cause potentially harmful effects. In vivo and vitro studies have shown that titanium dental implant corrosion can be induced by factors relating to bio-tribocorrosion. In this literature review, the consequences of titanium implant corrosion and particulate dissemination are discussed and later juxtaposed against a promising novel implant material, zirconia. Zirconia offers characteristics similar to titanium along with additional advantages such as being non-corrosive and having a lower propensity for inducing immune responses. From the mounting evidence discussed in this article, metal allergy testing would be advantageous for choosing an appropriate implant material to minimize potential adverse effects on cellular functions of local and diffuse tissues. Objective: This literature review aims to elucidate and describe mechanisms in which titanium implants may become corroded and induce cellular aberrations both locally and systemically in vivo. Implications of this study provide supportive evidence regarding the selection of appropriate biomaterials for implant patients susceptible to mounting a hypersensitivity reaction to titanium.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与钛植入物腐蚀和超敏反应有关的全身和局部相互作用:文献综述。
商业纯钛和钛合金都是成熟的骨植入生物材料,目前广泛应用于牙科。研究表明,钛微粒在某些患者群中会诱发细胞免疫介质,引起 I 型和 IV 型超敏反应,导致腐蚀加剧、骨溶解,增加种植失败的几率。从全身来看,钛颗粒会影响不同的器官组织,造成潜在的有害影响。体内和体外研究表明,钛金属牙科植入物的腐蚀可由生物三重腐蚀相关因素诱发。在这篇文献综述中,我们讨论了钛种植体腐蚀和微粒扩散的后果,随后将其与一种很有前途的新型种植体材料--氧化锆--进行对比。氧化锆具有与钛相似的特性,同时还具有无腐蚀性和较低的免疫反应倾向等优点。从本文讨论的越来越多的证据来看,金属过敏测试有利于选择合适的种植体材料,以尽量减少对局部和弥散组织细胞功能的潜在不利影响。目的:本文献综述旨在阐明和描述钛植入物在体内局部和全身发生腐蚀并诱发细胞畸变的机制。本研究的意义在于为容易对钛产生超敏反应的植入物患者选择合适的生物材料提供支持性证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
Reconstructive surgical treatment of peri-implantitis with use of a chitosan brush for decontamination- case series with 1-year follow-up. Brain-derived neurotrophic factor promotes bone regeneration in a canine model of peri-implantitis. The systemic and local interactions related to titanium implant corrosion and hypersensitivity reactions: a narrative review of the literature. Implant-supported fixed prostheses with cantilever: a systematic review and meta-analysis. A comparative study on bone density before and after implant placement using osseodensification technique: a clinical evaluation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1