Alexander Swalsky, Sammy S Noumbissi, Thomas G Wiedemann
{"title":"The systemic and local interactions related to titanium implant corrosion and hypersensitivity reactions: a narrative review of the literature.","authors":"Alexander Swalsky, Sammy S Noumbissi, Thomas G Wiedemann","doi":"10.1186/s40729-024-00578-3","DOIUrl":null,"url":null,"abstract":"<p><p>Both commercially pure titanium and titanium alloys are established biomaterials for implantation in bone and are widely used today in dentistry. Titanium particulates have been shown in some patient clusters to induce cellular immune mediators responsible for type I and IV hypersensitivity reactions, causing amplified corrosion, osteolysis, and increased odds of implant failure. Systemically, titanium particles were found to affect varying organ tissues and cause potentially harmful effects. In vivo and vitro studies have shown that titanium dental implant corrosion can be induced by factors relating to bio-tribocorrosion. In this literature review, the consequences of titanium implant corrosion and particulate dissemination are discussed and later juxtaposed against a promising novel implant material, zirconia. Zirconia offers characteristics similar to titanium along with additional advantages such as being non-corrosive and having a lower propensity for inducing immune responses. From the mounting evidence discussed in this article, metal allergy testing would be advantageous for choosing an appropriate implant material to minimize potential adverse effects on cellular functions of local and diffuse tissues. Objective: This literature review aims to elucidate and describe mechanisms in which titanium implants may become corroded and induce cellular aberrations both locally and systemically in vivo. Implications of this study provide supportive evidence regarding the selection of appropriate biomaterials for implant patients susceptible to mounting a hypersensitivity reaction to titanium.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"10 1","pages":"58"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11584828/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-024-00578-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Both commercially pure titanium and titanium alloys are established biomaterials for implantation in bone and are widely used today in dentistry. Titanium particulates have been shown in some patient clusters to induce cellular immune mediators responsible for type I and IV hypersensitivity reactions, causing amplified corrosion, osteolysis, and increased odds of implant failure. Systemically, titanium particles were found to affect varying organ tissues and cause potentially harmful effects. In vivo and vitro studies have shown that titanium dental implant corrosion can be induced by factors relating to bio-tribocorrosion. In this literature review, the consequences of titanium implant corrosion and particulate dissemination are discussed and later juxtaposed against a promising novel implant material, zirconia. Zirconia offers characteristics similar to titanium along with additional advantages such as being non-corrosive and having a lower propensity for inducing immune responses. From the mounting evidence discussed in this article, metal allergy testing would be advantageous for choosing an appropriate implant material to minimize potential adverse effects on cellular functions of local and diffuse tissues. Objective: This literature review aims to elucidate and describe mechanisms in which titanium implants may become corroded and induce cellular aberrations both locally and systemically in vivo. Implications of this study provide supportive evidence regarding the selection of appropriate biomaterials for implant patients susceptible to mounting a hypersensitivity reaction to titanium.
商业纯钛和钛合金都是成熟的骨植入生物材料,目前广泛应用于牙科。研究表明,钛微粒在某些患者群中会诱发细胞免疫介质,引起 I 型和 IV 型超敏反应,导致腐蚀加剧、骨溶解,增加种植失败的几率。从全身来看,钛颗粒会影响不同的器官组织,造成潜在的有害影响。体内和体外研究表明,钛金属牙科植入物的腐蚀可由生物三重腐蚀相关因素诱发。在这篇文献综述中,我们讨论了钛种植体腐蚀和微粒扩散的后果,随后将其与一种很有前途的新型种植体材料--氧化锆--进行对比。氧化锆具有与钛相似的特性,同时还具有无腐蚀性和较低的免疫反应倾向等优点。从本文讨论的越来越多的证据来看,金属过敏测试有利于选择合适的种植体材料,以尽量减少对局部和弥散组织细胞功能的潜在不利影响。目的:本文献综述旨在阐明和描述钛植入物在体内局部和全身发生腐蚀并诱发细胞畸变的机制。本研究的意义在于为容易对钛产生超敏反应的植入物患者选择合适的生物材料提供支持性证据。
期刊介绍:
The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.