High-precision dynamic axial clearance measurement method based on an all-fiber heterodyne microwave-AMCW with an all-phase tracking algorithm.

IF 3.2 2区 物理与天体物理 Q2 OPTICS Optics express Pub Date : 2024-11-04 DOI:10.1364/OE.539286
Zhenxin Yu, Fajie Duan, Xiao Fu, Guangyue Niu, Jiajia Jiang
{"title":"High-precision dynamic axial clearance measurement method based on an all-fiber heterodyne microwave-AMCW with an all-phase tracking algorithm.","authors":"Zhenxin Yu, Fajie Duan, Xiao Fu, Guangyue Niu, Jiajia Jiang","doi":"10.1364/OE.539286","DOIUrl":null,"url":null,"abstract":"<p><p>Rotor-stator axial clearance is critical to the safety and efficiency of major rotating machinery. However, factors such as high-speed rotation, narrow space, high temperature, and vibration present significant challenges for high-precision dynamic measurement of axial clearance. This paper proposes an axial clearance measurement method based on an all-fiber heterodyne microwave amplitude-modulated continuous wave (microwave-AMCW) system combined with an all-phase tracking algorithm, characterized by high precision, wide bandwidth, and a large measurement range. To mitigate environmental influences, a heterodyne all-fiber microwave-AMCW optical path structure is developed, and a compact dual-core fiber sensor probe is designed. The all-phase tracking algorithm is introduced to enhance dynamic precision and expand bandwidth. Additionally, what we believe to be a novel bandwidth test method based on time division multiplexing is proposed to evaluate the system's wide-bandwidth performance. The proposed system's performance is validated through simulations and experiments. The results demonstrate that the system exhibits excellent resistance to environmental interference, with a measurement range up to 24.5 mm and a static precision better than 4.5µm. Dynamic experiments further confirm the algorithm's effectiveness, achieving a precision better than 5.3µm at 100kHz bandwidth. Compared to other clearance measurement algorithms including the Hilbert transform and FFT, the proposed method reduces dynamic error by over 74%.</p>","PeriodicalId":19691,"journal":{"name":"Optics express","volume":"32 23","pages":"40945-40966"},"PeriodicalIF":3.2000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optics express","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1364/OE.539286","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Rotor-stator axial clearance is critical to the safety and efficiency of major rotating machinery. However, factors such as high-speed rotation, narrow space, high temperature, and vibration present significant challenges for high-precision dynamic measurement of axial clearance. This paper proposes an axial clearance measurement method based on an all-fiber heterodyne microwave amplitude-modulated continuous wave (microwave-AMCW) system combined with an all-phase tracking algorithm, characterized by high precision, wide bandwidth, and a large measurement range. To mitigate environmental influences, a heterodyne all-fiber microwave-AMCW optical path structure is developed, and a compact dual-core fiber sensor probe is designed. The all-phase tracking algorithm is introduced to enhance dynamic precision and expand bandwidth. Additionally, what we believe to be a novel bandwidth test method based on time division multiplexing is proposed to evaluate the system's wide-bandwidth performance. The proposed system's performance is validated through simulations and experiments. The results demonstrate that the system exhibits excellent resistance to environmental interference, with a measurement range up to 24.5 mm and a static precision better than 4.5µm. Dynamic experiments further confirm the algorithm's effectiveness, achieving a precision better than 5.3µm at 100kHz bandwidth. Compared to other clearance measurement algorithms including the Hilbert transform and FFT, the proposed method reduces dynamic error by over 74%.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于全光纤外差微波-AMCW 和全相跟踪算法的高精度动态轴向间隙测量方法。
转子-定子轴向间隙对主要旋转机械的安全和效率至关重要。然而,高速旋转、狭窄空间、高温和振动等因素给轴向间隙的高精度动态测量带来了巨大挑战。本文提出了一种基于全光纤外差微波调幅连续波(微波-AMCW)系统的轴向间隙测量方法,该方法结合了全相位跟踪算法,具有精度高、带宽宽、测量范围大等特点。为减轻环境影响,开发了一种异频全光纤微波-AMCW 光路结构,并设计了一种紧凑型双核光纤传感器探头。我们引入了全相位跟踪算法,以提高动态精度并扩展带宽。此外,我们还提出了一种基于时分复用的新型带宽测试方法,用于评估系统的宽带性能。我们通过模拟和实验验证了拟议系统的性能。结果表明,该系统具有出色的抗环境干扰能力,测量范围可达 24.5 毫米,静态精度优于 4.5 微米。动态实验进一步证实了该算法的有效性,在 100kHz 带宽下精度优于 5.3µm。与希尔伯特变换和 FFT 等其他间隙测量算法相比,所提出的方法可将动态误差减少 74% 以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Optics express
Optics express 物理-光学
CiteScore
6.60
自引率
15.80%
发文量
5182
审稿时长
2.1 months
期刊介绍: Optics Express is the all-electronic, open access journal for optics providing rapid publication for peer-reviewed articles that emphasize scientific and technology innovations in all aspects of optics and photonics.
期刊最新文献
Adaptive generation of optical single-sideband signal with dually modulated EML. Manipulating reflection-type all-dielectric non-local metasurfaces via the parity of a particle number. SSBI counteraction technology in a single photodetector-based direct detection system receiving an independent dual-single sideband signal. Adaptive-modulated fast fluctuation super-resolution microscopy. Measurement and analysis of photoacoustic pressure induced by weak microsecond pulsed light.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1