{"title":"Relationship between hyoid-carotid distance, hyoid position and morphology and degree of stenosis and associated stroke","authors":"Emmanuel Salaun-Penquer MD , Sabine Laurent-Chabalier PhD , Cassiana Trandafir MD , Catalin Cosma MD , Teodora Parvu MD , Anne Wacongne MD , Eric Thouvenot MD, PhD , Dimitri Renard MD","doi":"10.1016/j.jstrokecerebrovasdis.2024.108106","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Pressure on carotid artery by hyoid bone may influence plaque formation. We studied CTA-based hyoid-carotid anatomical interaction and its relationship with carotid stenosis degree and stenosis-related stroke.</div></div><div><h3>Methods</h3><div>We retrospectively analysed pre-operative CTA of 205 consecutive adults having undergone carotid endarterectomy (CEA) for asymptomatic or symptomatic stenosis. Radiological measurements were: degree stenosis, hyoid-carotid distance, carotid position in regard to hyoid, and hyoid morphology.</div></div><div><h3>Results</h3><div>In total, 410 carotids (including 114 symptomatic and 296 asymptomatic stenotic and non-stenotic carotids) from 205 CEA patients (median age 74, 72% men) were analysed. Median carotid stenosis was 61% (70% for symptomatic and 51% for asymptomatic carotids, p<0.0001; 70% for CEA and 30.5% for non-CEA carotids, p<0.0001). None of the other radiological parameters differed between asymptomatic/symptomatic carotids, between non-CEA/CEA carotids, or between asymptomatic/symptomatic patients. Median hyoid-carotid distance was 4.3mm, with 82% of carotids in posterolateral quadrant position in regard to the hyoid. There was no correlation between stenosis degree and hyoid-carotid distance (rho=-0.039), hyoid width (rho=-0.079), length (rho=0.007) or circumferential length (rho=-0.005), and stenosis degree was comparable between different carotid position quadrants (p=0.51).</div></div><div><h3>Conclusions</h3><div>Hyoid-carotid distance, hyoid position and morphology are not correlated with the degree of carotid stenosis or symptomatic carotid stenosis.</div></div><div><h3>Clinical Trial Registration-URL</h3><div><span><span>http://www.clinicaltrials.gov</span><svg><path></path></svg></span>: Unique identifier: NCT05349526</div></div>","PeriodicalId":54368,"journal":{"name":"Journal of Stroke & Cerebrovascular Diseases","volume":"34 1","pages":"Article 108106"},"PeriodicalIF":2.0000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stroke & Cerebrovascular Diseases","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1052305724005494","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Pressure on carotid artery by hyoid bone may influence plaque formation. We studied CTA-based hyoid-carotid anatomical interaction and its relationship with carotid stenosis degree and stenosis-related stroke.
Methods
We retrospectively analysed pre-operative CTA of 205 consecutive adults having undergone carotid endarterectomy (CEA) for asymptomatic or symptomatic stenosis. Radiological measurements were: degree stenosis, hyoid-carotid distance, carotid position in regard to hyoid, and hyoid morphology.
Results
In total, 410 carotids (including 114 symptomatic and 296 asymptomatic stenotic and non-stenotic carotids) from 205 CEA patients (median age 74, 72% men) were analysed. Median carotid stenosis was 61% (70% for symptomatic and 51% for asymptomatic carotids, p<0.0001; 70% for CEA and 30.5% for non-CEA carotids, p<0.0001). None of the other radiological parameters differed between asymptomatic/symptomatic carotids, between non-CEA/CEA carotids, or between asymptomatic/symptomatic patients. Median hyoid-carotid distance was 4.3mm, with 82% of carotids in posterolateral quadrant position in regard to the hyoid. There was no correlation between stenosis degree and hyoid-carotid distance (rho=-0.039), hyoid width (rho=-0.079), length (rho=0.007) or circumferential length (rho=-0.005), and stenosis degree was comparable between different carotid position quadrants (p=0.51).
Conclusions
Hyoid-carotid distance, hyoid position and morphology are not correlated with the degree of carotid stenosis or symptomatic carotid stenosis.
期刊介绍:
The Journal of Stroke & Cerebrovascular Diseases publishes original papers on basic and clinical science related to the fields of stroke and cerebrovascular diseases. The Journal also features review articles, controversies, methods and technical notes, selected case reports and other original articles of special nature. Its editorial mission is to focus on prevention and repair of cerebrovascular disease. Clinical papers emphasize medical and surgical aspects of stroke, clinical trials and design, epidemiology, stroke care delivery systems and outcomes, imaging sciences and rehabilitation of stroke. The Journal will be of special interest to specialists involved in caring for patients with cerebrovascular disease, including neurologists, neurosurgeons and cardiologists.