The diagnositic value of dynamic contrast-enhanced ultrasound for evaluation of tissue oxygen status in rat hepatoma model.

IF 2.5 3区 医学 Q2 GASTROENTEROLOGY & HEPATOLOGY BMC Gastroenterology Pub Date : 2024-11-23 DOI:10.1186/s12876-024-03523-1
Bo Jiang, LuDa Song, Xiang Fei, JiaNing Zhu, LianHua Zhu, QiuYang Li, YuKun Luo
{"title":"The diagnositic value of dynamic contrast-enhanced ultrasound for evaluation of tissue oxygen status in rat hepatoma model.","authors":"Bo Jiang, LuDa Song, Xiang Fei, JiaNing Zhu, LianHua Zhu, QiuYang Li, YuKun Luo","doi":"10.1186/s12876-024-03523-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hypoxia is a characteristic of solid tumors, but whether significant hypoxia exists in the hepatocellular carcinoma remains unclear. This animal study aims to explore the value of dynamic contrast-enhanced ultrasound (CEUS) quantitative parameters to evaluate the oxygen status in two rat hepatoma models.</p><p><strong>Materials and methods: </strong>N1S1 and McA-RH7777 S-D rat orthotopic hepatoma models were established. Once the tumors reached a diameter of 10-15 mm, CEUS and oxygen partial pressure (pO2) polarography were performed. Immunohistochemical staining for HIF-1α and pimonidazole was conducted after euthanizing the rats. Correlation between quantitative CEUS parameters, pO<sub>2,</sub> and the immunohistochemical integrated optical density (IOD) was analyzed to assess the predictive ability of CEUS quantitative parameters for the tissue oxygen environment.</p><p><strong>Result: </strong>Eleven N1S1 models and ten McA-RH7777 models were established successfully. There was no significant difference in pO<sub>2</sub> (35.5 mmHg vs 32.2 mmHg, P = 0.917), IOD of HIF-1α (13.4 vs 20.0, P = 0.159) and pimonidazole (0.70 vs 1.30, P = 0.926) between the tumor and the peritumoral liver tissue. The pO<sub>2</sub> values were correlated with CEUS quantitative parameters including mean time-intensity curves (mTIC) (P = 0.003), peak intensity (PKI) (P = 0.010), area under the curve (AUC) (P = 0.009), area under the wash-in curve (WiAUC) (P = 0.006), and arrival time (AT) (P = 0.033). The IOD of HIF-1α correlated with AUC (P = 0.022), WiAUC (P = 0.009), ascending slope (AS) (P = 0.044), and falling time (FT) (P = 0.009). Multiple linear regression indicated that the \"short AT\" was an independent protective factor for hypoxia (β = -2.347, 95% CI: -4.948, -0.394, P = 0.022), and CEUS had the ability to predict the tumor pO<sub>2</sub> (P = 0.003).</p><p><strong>Conclusion: </strong>No evidence of significant hypoxia was identified in two rat orthotopic hepatoma models. Quantitative CEUS parameters correlated with the oxygen status of the tumor, which could be utilized to predict the tumor tissue pO<sub>2</sub>.</p>","PeriodicalId":9129,"journal":{"name":"BMC Gastroenterology","volume":"24 1","pages":"424"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12876-024-03523-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Hypoxia is a characteristic of solid tumors, but whether significant hypoxia exists in the hepatocellular carcinoma remains unclear. This animal study aims to explore the value of dynamic contrast-enhanced ultrasound (CEUS) quantitative parameters to evaluate the oxygen status in two rat hepatoma models.

Materials and methods: N1S1 and McA-RH7777 S-D rat orthotopic hepatoma models were established. Once the tumors reached a diameter of 10-15 mm, CEUS and oxygen partial pressure (pO2) polarography were performed. Immunohistochemical staining for HIF-1α and pimonidazole was conducted after euthanizing the rats. Correlation between quantitative CEUS parameters, pO2, and the immunohistochemical integrated optical density (IOD) was analyzed to assess the predictive ability of CEUS quantitative parameters for the tissue oxygen environment.

Result: Eleven N1S1 models and ten McA-RH7777 models were established successfully. There was no significant difference in pO2 (35.5 mmHg vs 32.2 mmHg, P = 0.917), IOD of HIF-1α (13.4 vs 20.0, P = 0.159) and pimonidazole (0.70 vs 1.30, P = 0.926) between the tumor and the peritumoral liver tissue. The pO2 values were correlated with CEUS quantitative parameters including mean time-intensity curves (mTIC) (P = 0.003), peak intensity (PKI) (P = 0.010), area under the curve (AUC) (P = 0.009), area under the wash-in curve (WiAUC) (P = 0.006), and arrival time (AT) (P = 0.033). The IOD of HIF-1α correlated with AUC (P = 0.022), WiAUC (P = 0.009), ascending slope (AS) (P = 0.044), and falling time (FT) (P = 0.009). Multiple linear regression indicated that the "short AT" was an independent protective factor for hypoxia (β = -2.347, 95% CI: -4.948, -0.394, P = 0.022), and CEUS had the ability to predict the tumor pO2 (P = 0.003).

Conclusion: No evidence of significant hypoxia was identified in two rat orthotopic hepatoma models. Quantitative CEUS parameters correlated with the oxygen status of the tumor, which could be utilized to predict the tumor tissue pO2.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
动态对比增强超声对大鼠肝癌模型组织氧状态评估的诊断价值
背景:缺氧是实体瘤的一个特征,但肝细胞癌是否存在明显的缺氧仍不清楚。本动物研究旨在探索动态对比增强超声(CEUS)定量参数在两种大鼠肝癌模型中评估氧状态的价值:材料:建立了 N1S1 和 McA-RH7777 S-D 大鼠正位肝癌模型。当肿瘤直径达到 10-15 mm 时,进行 CEUS 和氧分压(pO2)极谱分析。大鼠安乐死后进行了 HIF-1α 和匹莫尼达唑的免疫组化染色。分析了CEUS定量参数、pO2和免疫组化综合光密度(IOD)之间的相关性,以评估CEUS定量参数对组织氧环境的预测能力:结果:成功建立了11个N1S1模型和10个McA-RH7777模型。肿瘤和瘤周肝组织的 pO2(35.5 mmHg vs 32.2 mmHg,P = 0.917)、HIF-1α 的 IOD(13.4 vs 20.0,P = 0.159)和波尼达克(0.70 vs 1.30,P = 0.926)无明显差异。pO2值与CEUS定量参数相关,包括平均时间-强度曲线(mTIC)(P = 0.003)、峰值强度(PKI)(P = 0.010)、曲线下面积(AUC)(P = 0.009)、冲洗曲线下面积(WiAUC)(P = 0.006)和到达时间(AT)(P = 0.033)。HIF-1α 的 IOD 与 AUC(P = 0.022)、WiAUC(P = 0.009)、上升斜率(AS)(P = 0.044)和下降时间(FT)(P = 0.009)相关。多元线性回归表明,"短AT "是缺氧的独立保护因素(β = -2.347,95% CI:-4.948,-0.394,P = 0.022),CEUS具有预测肿瘤pO2的能力(P = 0.003):结论:在两个大鼠正位肝癌模型中未发现明显缺氧的证据。CEUS定量参数与肿瘤的氧状态相关,可用于预测肿瘤组织的pO2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Gastroenterology
BMC Gastroenterology 医学-胃肠肝病学
CiteScore
4.20
自引率
0.00%
发文量
465
审稿时长
6 months
期刊介绍: BMC Gastroenterology is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of gastrointestinal and hepatobiliary disorders, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
The diagnositic value of dynamic contrast-enhanced ultrasound for evaluation of tissue oxygen status in rat hepatoma model. Impact of Ahmadi Continuing Nursing Model on self-care ability, stoma complications and quality of life of colostomy patients. Rhaponticin suppresses the stemness phenotype of gastric cancer stem-like cells CD133+/CD166 + by inhibiting programmed death-ligand 1. The association between non- and pro-healthy diet indices and the risk of colorectal cancer: a case-control study. The effect of propranolol on gastrointestinal motility and permeability in patients with cirrhosis and significant portal hypertension.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1