Three-dimensional models demonstrate differences in correction depending on femoral derotational osteotomy site and may enhance the planning and precision in femoral derotational osteotomy – An observational study in eight femora and two surgeons
Caterina Chiappe , Alejandro Roselló-Añón , Vicente Sanchis-Alfonso , Joan Carles Monllau , Julio Domenech-Fernández
{"title":"Three-dimensional models demonstrate differences in correction depending on femoral derotational osteotomy site and may enhance the planning and precision in femoral derotational osteotomy – An observational study in eight femora and two surgeons","authors":"Caterina Chiappe , Alejandro Roselló-Añón , Vicente Sanchis-Alfonso , Joan Carles Monllau , Julio Domenech-Fernández","doi":"10.1016/j.knee.2024.10.023","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Increased femoral anteversion (FAV) is crucial in the genesis of anterior knee pain (AKP) and a femoral derotational osteotomy (FDO) has demonstrated good clinical results. It remains unclear at what level of the femur the osteotomy should be performed. Resulting degrees of FAV measured by Murphy’s method do not always correspond to the degrees that had been planned after an FDO. The hypothesis of this study is that the femur rotation axis and the osteotomy rotation axis do not coincide. Three-dimensional (3D) technology is used to objectify the discrepancy between these two axes and to find solutions so that the two axes can coincide. The objective is to demonstrate the reliability and reproducibility of the 3D technique for osteotomy adjustment through an intraobserver and interobserver study.</div></div><div><h3>Methods</h3><div>Images of eight computed tomography scans of the femur, corresponding to seven patients with a diagnosis of AKP and increased FAV, were selected. Two surgeons performed the FAV measurement and simulation of FDO on 3D biomodels. The femoral osteotomies were defined at three levels, at 10°, 20°, 30°. To determine interobserver agreement, measurements were performed independently by two surgeons. To evaluate intraobserver differences each surgeon repeated all measurements after 15 days.</div></div><div><h3>Results</h3><div>Interobserver and intraobserver agreement: intraclass correlation coefficient 0.930 (95% confidence interval (CI) 0.799–0.975) and 0.986 (95% CI 0.959–0.995). Significant differences between the resulting values were observed when the osteotomy was performed at the intertrochanteric level.</div></div><div><h3>Conclusions</h3><div>The misalignment of the axes results in hypocorrection when the osteotomy is intertrochanteric. This phenomenon is not observed when the osteotomy is diaphyseal or supracondylar.</div></div>","PeriodicalId":56110,"journal":{"name":"Knee","volume":"52 ","pages":"Pages 131-138"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0968016024002047","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Increased femoral anteversion (FAV) is crucial in the genesis of anterior knee pain (AKP) and a femoral derotational osteotomy (FDO) has demonstrated good clinical results. It remains unclear at what level of the femur the osteotomy should be performed. Resulting degrees of FAV measured by Murphy’s method do not always correspond to the degrees that had been planned after an FDO. The hypothesis of this study is that the femur rotation axis and the osteotomy rotation axis do not coincide. Three-dimensional (3D) technology is used to objectify the discrepancy between these two axes and to find solutions so that the two axes can coincide. The objective is to demonstrate the reliability and reproducibility of the 3D technique for osteotomy adjustment through an intraobserver and interobserver study.
Methods
Images of eight computed tomography scans of the femur, corresponding to seven patients with a diagnosis of AKP and increased FAV, were selected. Two surgeons performed the FAV measurement and simulation of FDO on 3D biomodels. The femoral osteotomies were defined at three levels, at 10°, 20°, 30°. To determine interobserver agreement, measurements were performed independently by two surgeons. To evaluate intraobserver differences each surgeon repeated all measurements after 15 days.
Results
Interobserver and intraobserver agreement: intraclass correlation coefficient 0.930 (95% confidence interval (CI) 0.799–0.975) and 0.986 (95% CI 0.959–0.995). Significant differences between the resulting values were observed when the osteotomy was performed at the intertrochanteric level.
Conclusions
The misalignment of the axes results in hypocorrection when the osteotomy is intertrochanteric. This phenomenon is not observed when the osteotomy is diaphyseal or supracondylar.
期刊介绍:
The Knee is an international journal publishing studies on the clinical treatment and fundamental biomechanical characteristics of this joint. The aim of the journal is to provide a vehicle relevant to surgeons, biomedical engineers, imaging specialists, materials scientists, rehabilitation personnel and all those with an interest in the knee.
The topics covered include, but are not limited to:
• Anatomy, physiology, morphology and biochemistry;
• Biomechanical studies;
• Advances in the development of prosthetic, orthotic and augmentation devices;
• Imaging and diagnostic techniques;
• Pathology;
• Trauma;
• Surgery;
• Rehabilitation.