Three-dimensional models demonstrate differences in correction depending on femoral derotational osteotomy site and may enhance the planning and precision in femoral derotational osteotomy – An observational study in eight femora and two surgeons

IF 1.6 4区 医学 Q3 ORTHOPEDICS Knee Pub Date : 2024-11-21 DOI:10.1016/j.knee.2024.10.023
Caterina Chiappe , Alejandro Roselló-Añón , Vicente Sanchis-Alfonso , Joan Carles Monllau , Julio Domenech-Fernández
{"title":"Three-dimensional models demonstrate differences in correction depending on femoral derotational osteotomy site and may enhance the planning and precision in femoral derotational osteotomy – An observational study in eight femora and two surgeons","authors":"Caterina Chiappe ,&nbsp;Alejandro Roselló-Añón ,&nbsp;Vicente Sanchis-Alfonso ,&nbsp;Joan Carles Monllau ,&nbsp;Julio Domenech-Fernández","doi":"10.1016/j.knee.2024.10.023","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Increased femoral anteversion (FAV) is crucial in the genesis of anterior knee pain (AKP) and a femoral derotational osteotomy (FDO) has demonstrated good clinical results. It remains unclear at what level of the femur the osteotomy should be performed. Resulting degrees of FAV measured by Murphy’s method do not always correspond to the degrees that had been planned after an FDO. The hypothesis of this study is that the femur rotation axis and the osteotomy rotation axis do not coincide. Three-dimensional (3D) technology is used to objectify the discrepancy between these two axes and to find solutions so that the two axes can coincide. The objective is to demonstrate the reliability and reproducibility of the 3D technique for osteotomy adjustment through an intraobserver and interobserver study.</div></div><div><h3>Methods</h3><div>Images of eight computed tomography scans of the femur, corresponding to seven patients with a diagnosis of AKP and increased FAV, were selected. Two surgeons performed the FAV measurement and simulation of FDO on 3D biomodels. The femoral osteotomies were defined at three levels, at 10°, 20°, 30°. To determine interobserver agreement, measurements were performed independently by two surgeons. To evaluate intraobserver differences each surgeon repeated all measurements after 15 days.</div></div><div><h3>Results</h3><div>Interobserver and intraobserver agreement: intraclass correlation coefficient 0.930 (95% confidence interval (CI) 0.799–0.975) and 0.986 (95% CI 0.959–0.995). Significant differences between the resulting values were observed when the osteotomy was performed at the intertrochanteric level.</div></div><div><h3>Conclusions</h3><div>The misalignment of the axes results in hypocorrection when the osteotomy is intertrochanteric. This phenomenon is not observed when the osteotomy is diaphyseal or supracondylar.</div></div>","PeriodicalId":56110,"journal":{"name":"Knee","volume":"52 ","pages":"Pages 131-138"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0968016024002047","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Increased femoral anteversion (FAV) is crucial in the genesis of anterior knee pain (AKP) and a femoral derotational osteotomy (FDO) has demonstrated good clinical results. It remains unclear at what level of the femur the osteotomy should be performed. Resulting degrees of FAV measured by Murphy’s method do not always correspond to the degrees that had been planned after an FDO. The hypothesis of this study is that the femur rotation axis and the osteotomy rotation axis do not coincide. Three-dimensional (3D) technology is used to objectify the discrepancy between these two axes and to find solutions so that the two axes can coincide. The objective is to demonstrate the reliability and reproducibility of the 3D technique for osteotomy adjustment through an intraobserver and interobserver study.

Methods

Images of eight computed tomography scans of the femur, corresponding to seven patients with a diagnosis of AKP and increased FAV, were selected. Two surgeons performed the FAV measurement and simulation of FDO on 3D biomodels. The femoral osteotomies were defined at three levels, at 10°, 20°, 30°. To determine interobserver agreement, measurements were performed independently by two surgeons. To evaluate intraobserver differences each surgeon repeated all measurements after 15 days.

Results

Interobserver and intraobserver agreement: intraclass correlation coefficient 0.930 (95% confidence interval (CI) 0.799–0.975) and 0.986 (95% CI 0.959–0.995). Significant differences between the resulting values were observed when the osteotomy was performed at the intertrochanteric level.

Conclusions

The misalignment of the axes results in hypocorrection when the osteotomy is intertrochanteric. This phenomenon is not observed when the osteotomy is diaphyseal or supracondylar.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维模型显示股骨截骨部位不同,矫正效果也不同,可提高股骨截骨术的计划性和精确性 - 一项针对 8 个股骨和 2 名外科医生的观察研究。
背景:股骨外翻(FAV)是导致膝前疼痛(AKP)的关键因素,而股骨外翻截骨术(FDO)具有良好的临床效果。目前仍不清楚应在股骨的哪个水平进行截骨。用 Murphy's 方法测量的 FAV 度数并不总是与 FDO 后计划的度数一致。本研究的假设是股骨旋转轴与截骨旋转轴不一致。三维(3D)技术被用来确定这两个轴线之间的差异,并找到解决方案,使两个轴线能够重合。目的是通过一项观察者内部和观察者之间的研究,证明三维技术在截骨调整方面的可靠性和可重复性:方法:选取七名确诊为 AKP 且 FAV 增高的患者的八张股骨计算机断层扫描图像。两名外科医生在三维生物模型上进行FAV测量和FDO模拟。股骨截骨分为 10°、20° 和 30°三个级别。为确定观察者之间的一致性,由两名外科医生独立进行测量。为评估观察者内部差异,每位外科医生在 15 天后重复所有测量:观察者间和观察者内的一致性:类内相关系数分别为 0.930(95% 置信区间(CI)0.799-0.975)和 0.986(95% 置信区间(CI)0.959-0.995)。在转子间水平进行截骨时,观察到结果值之间存在显著差异:结论:在转子间水平进行截骨时,轴线的错位会导致矫正不足。结论:在转子间进行截骨时,轴线的错位会导致低校正,而在二骺或髁上进行截骨时则不会出现这种现象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Knee
Knee 医学-外科
CiteScore
3.80
自引率
5.30%
发文量
171
审稿时长
6 months
期刊介绍: The Knee is an international journal publishing studies on the clinical treatment and fundamental biomechanical characteristics of this joint. The aim of the journal is to provide a vehicle relevant to surgeons, biomedical engineers, imaging specialists, materials scientists, rehabilitation personnel and all those with an interest in the knee. The topics covered include, but are not limited to: • Anatomy, physiology, morphology and biochemistry; • Biomechanical studies; • Advances in the development of prosthetic, orthotic and augmentation devices; • Imaging and diagnostic techniques; • Pathology; • Trauma; • Surgery; • Rehabilitation.
期刊最新文献
SPECT-CT may aid in determining which side of a revision stemmed implant problematic total knee replacement is loose when planning revision surgery The third gap – The forgotten space in total knee arthroplasty Biomechanical differences of Asian knee osteoarthritis patients during standing and walking using statistical parametric mapping: A cross-sectional study Non-steroidal anti-inflammatory drugs influence cartilage healing Patellar tendon–Hoffa fat pad interface: From anatomy to high-resolution ultrasound imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1