{"title":"Validation of an Augmented Reality Based Functional Method to Determine and Render the Hip Rotation Centre During Total Hip Arthroplasty.","authors":"Quentin Neuville, Taylor Frantz, Frederick Van Gestel, Bart Janssen, Jef Vandemeulebroucke, Johnny Duerinck, Thierry Scheerlinck","doi":"10.1002/rcs.70011","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We present a method to determine and visualise the functional centre of rotation (FCOR) of the hip during total hip arthroplasty using an augmented reality head mounted display (AR-HMD).</p><p><strong>Methods: </strong>We developed software allowing a HoloLens to provide inside-out infrared tracking of markers affixed to cadaver femurs and 3D printed acetabuli. Two observers rotated 20 cadaver femurs twice in a matching cup, producing 80 measurements. The FCOR of the acetabulum and femoral head was determined based on the point cloud generated from the displacement of the femoral trackers to the acetabular tracker.</p><p><strong>Results: </strong>Compared to the ground truth, the FCOR resulted in an absolute error of 2.9 ± 1.4 mm for the acetabulum and 2.9 ± 1.2 mm for the femur, with 95th percentiles below 5.6 and 4.7 mm.</p><p><strong>Conclusion: </strong>The proposed AR-HMD system offers an accurate and reproducible way to determine the femoral and acetabular FCOR in an experimental setting.</p>","PeriodicalId":75029,"journal":{"name":"The international journal of medical robotics + computer assisted surgery : MRCAS","volume":"20 6","pages":"e70011"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The international journal of medical robotics + computer assisted surgery : MRCAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/rcs.70011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: We present a method to determine and visualise the functional centre of rotation (FCOR) of the hip during total hip arthroplasty using an augmented reality head mounted display (AR-HMD).

Methods: We developed software allowing a HoloLens to provide inside-out infrared tracking of markers affixed to cadaver femurs and 3D printed acetabuli. Two observers rotated 20 cadaver femurs twice in a matching cup, producing 80 measurements. The FCOR of the acetabulum and femoral head was determined based on the point cloud generated from the displacement of the femoral trackers to the acetabular tracker.

Results: Compared to the ground truth, the FCOR resulted in an absolute error of 2.9 ± 1.4 mm for the acetabulum and 2.9 ± 1.2 mm for the femur, with 95th percentiles below 5.6 and 4.7 mm.

Conclusion: The proposed AR-HMD system offers an accurate and reproducible way to determine the femoral and acetabular FCOR in an experimental setting.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
验证基于增强现实的功能性方法,以确定和渲染全髋关节置换术中的髋关节旋转中心。
背景:我们介绍了一种在全髋关节置换术中使用增强现实头戴式显示器(AR-HMD)确定和可视化髋关节功能旋转中心(FCOR)的方法:我们开发了一款软件,允许 HoloLens 对贴在尸体股骨和 3D 打印髋臼上的标记进行由内而外的红外跟踪。两名观察者在一个匹配杯中旋转 20 个尸体股骨两次,共进行了 80 次测量。髋臼和股骨头的 FCOR 是根据股骨追踪器与髋臼追踪器的位移所产生的点云确定的:与地面实况相比,髋臼和股骨的 FCOR 绝对误差分别为 2.9 ± 1.4 毫米和 2.9 ± 1.2 毫米,第 95 百分位数分别低于 5.6 毫米和 4.7 毫米:结论:拟议的 AR-HMD 系统为在实验环境中确定股骨和髋臼的 FCOR 提供了一种准确且可重复的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
0.00%
发文量
0
期刊最新文献
Multi-Objective Safety-Enhanced Path Planning for the Anterior Part of a Flexible Ureteroscope in Robot-Assisted Surgery. Validation of an Augmented Reality Based Functional Method to Determine and Render the Hip Rotation Centre During Total Hip Arthroplasty. Comparison of robotic and open central pancreatectomy. Full coverage path planning algorithm for MRgFUS therapy A deep learning framework for real‐time 3D model registration in robot‐assisted laparoscopic surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1