{"title":"Flame Atomic Absorption Spectroscopy Combined with a New Univariate Strategy for Optimization of Cd(II) Preconcentration Procedure: Salicylideneaniline as Complexation-Agent-Based Traditional Dispersive Liquid-Liquid Microextraction","authors":"Zaman Sahb Mehdi,&nbsp;Saher A. Ali Alshamkhawy","doi":"10.1007/s10812-024-01836-3","DOIUrl":null,"url":null,"abstract":"<p>A procedure based on dispersive liquid-liquid microextraction (DLLME) for cadmium (Cd) quantification in an Iraqi environmental matrix by flame atomic absorption spectroscopy (FAAS) was applied in this work. A case study approach was chosen to obtain further in-depth information on the Cd levels and to evaluate the effectiveness of N-salicylideneaniline (SAN) as a complexing agent for preconcentration and extraction of Cd. Univariate strategy was utilized for achieving the optimum extraction conditions: 75.0 μL of carbon tetrachloride as the extraction solvent, 10 mL of a sample solution adjusted the pH at 8.50 containing 0.8% (w/v) SAN, and 1400 μL of methanol as the dispersive solvent, within 30 s complexation time. The estimated limits of detection (LOD) and quantification (LOQ) under optimum conditions were 0.26 and 0.87 μg/L, respectively. Enrichment factors were obtained in two manners, found to be 24.4 and 44.3. To evaluate the accuracy of the method, known amounts of analytes were spiked and compared with the results achieved using microwave digestion/graphite furnace atomic absorption spectrometer (MWD/GF-AAS) for solid samples, and direct graphite furnace atomic absorption spectrometer (GF-AAS) for water samples. Procedure was applied for analyzing eight environmental samples, the Cd levels for water samples ranged from 3.01 to 7.33 μg/L with a relative standard deviation (4.1–10.4 RSD%), while the concentration for the solid sample (Mentha piperita) was 2.71 μg/g (RSD% = 7.4). DLLME/FAAS proposed procedure is eff ective, simple, and has the benefi t of minimizing the organic solvent consumption, by a few microliters, which results in little waste.</p>","PeriodicalId":609,"journal":{"name":"Journal of Applied Spectroscopy","volume":"91 5","pages":"1187 - 1195"},"PeriodicalIF":0.8000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10812-024-01836-3","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

A procedure based on dispersive liquid-liquid microextraction (DLLME) for cadmium (Cd) quantification in an Iraqi environmental matrix by flame atomic absorption spectroscopy (FAAS) was applied in this work. A case study approach was chosen to obtain further in-depth information on the Cd levels and to evaluate the effectiveness of N-salicylideneaniline (SAN) as a complexing agent for preconcentration and extraction of Cd. Univariate strategy was utilized for achieving the optimum extraction conditions: 75.0 μL of carbon tetrachloride as the extraction solvent, 10 mL of a sample solution adjusted the pH at 8.50 containing 0.8% (w/v) SAN, and 1400 μL of methanol as the dispersive solvent, within 30 s complexation time. The estimated limits of detection (LOD) and quantification (LOQ) under optimum conditions were 0.26 and 0.87 μg/L, respectively. Enrichment factors were obtained in two manners, found to be 24.4 and 44.3. To evaluate the accuracy of the method, known amounts of analytes were spiked and compared with the results achieved using microwave digestion/graphite furnace atomic absorption spectrometer (MWD/GF-AAS) for solid samples, and direct graphite furnace atomic absorption spectrometer (GF-AAS) for water samples. Procedure was applied for analyzing eight environmental samples, the Cd levels for water samples ranged from 3.01 to 7.33 μg/L with a relative standard deviation (4.1–10.4 RSD%), while the concentration for the solid sample (Mentha piperita) was 2.71 μg/g (RSD% = 7.4). DLLME/FAAS proposed procedure is eff ective, simple, and has the benefi t of minimizing the organic solvent consumption, by a few microliters, which results in little waste.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
本研究采用分散液液微萃取法(DLLME),通过火焰原子吸收光谱(FAAS)对伊拉克环境基质中的镉(Cd)进行定量。为了进一步深入了解镉的含量,并评估 N-水杨酰苯胺(SAN)作为络合剂在预富集和萃取镉方面的效果,我们选择了案例研究法。采用单变量策略确定最佳萃取条件:萃取溶剂为 75.0 μL 四氯化碳,10 mL 含有 0.8%(w/v)SAN 的 pH 值为 8.50 的样品溶液,分散溶剂为 1400 μL 甲醇,络合时间为 30 s。在最佳条件下,估计检出限(LOD)和定量限(LOQ)分别为 0.26 和 0.87 μg/L。富集因子有两种方法,分别为 24.4 和 44.3。为了评估该方法的准确性,在固体样品中添加了已知量的分析物,并与使用微波消解/石墨炉原子吸收光谱仪(MWD/GF-AAS)和直接石墨炉原子吸收光谱仪(GF-AAS)分析水样的结果进行了比较。应用该程序分析了八个环境样品,水样的镉含量为 3.01 至 7.33 微克/升,相对标准偏差为 4.1-10.4 RSD%;固体样品(薄荷)的镉含量为 2.71 微克/克(RSD% = 7.4)。所提议的 DLLME/FAAS 程序有效、简单,而且最大限度地减少了有机溶剂的消耗,只需几微升,几乎不会造成浪费。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
14.30%
发文量
145
审稿时长
2.5 months
期刊介绍: Journal of Applied Spectroscopy reports on many key applications of spectroscopy in chemistry, physics, metallurgy, and biology. An increasing number of papers focus on the theory of lasers, as well as the tremendous potential for the practical applications of lasers in numerous fields and industries.
期刊最新文献
Flame Atomic Absorption Spectroscopy Combined with a New Univariate Strategy for Optimization of Cd(II) Preconcentration Procedure: Salicylideneaniline as Complexation-Agent-Based Traditional Dispersive Liquid-Liquid Microextraction Derivative UV-Spectrophotometric Assay Methods for Determination of Ivacaftor Rapid Detection of Imidacloprid in Apple Juice by Ultraviolet Spectroscopy Coupled with Support Vector Regression and Variable Selection Methods Synthesis and Luminescence Properties of Na2Al2B2O7:M (M = Dy3+ and Sm3+) Regularities of Formation, Taking Into Account the Sizes of the Object, of Spatial-Energy Profile of the Signal Recorded by Active-Pulse Vision Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1