Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results.

IF 5.5 3区 医学 Q1 PHARMACOLOGY & PHARMACY Pharmaceutics Pub Date : 2024-11-20 DOI:10.3390/pharmaceutics16111480
Yusuke Tsuboko, Hideyuki Sakoda, Yoshihiro Okamoto, Yusuke Nomura, Eiichi Yamamoto
{"title":"Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results.","authors":"Yusuke Tsuboko, Hideyuki Sakoda, Yoshihiro Okamoto, Yusuke Nomura, Eiichi Yamamoto","doi":"10.3390/pharmaceutics16111480","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). <b>Methods:</b> Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load-displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. <b>Results:</b> The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. <b>Conclusions:</b> Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.</p>","PeriodicalId":19894,"journal":{"name":"Pharmaceutics","volume":"16 11","pages":""},"PeriodicalIF":5.5000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11597646/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/pharmaceutics16111480","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). Methods: Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load-displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. Results: The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. Conclusions: Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微针阵列中单个针头的机械特性分析:影响压缩测试结果的因素
背景:本研究旨在探讨测试条件对微针阵(MNA)压缩测试结果的影响。方法:对聚乙二醇纤维板进行单轴压缩试验:对聚乙二醇酸制成的可生物降解微针阵列进行单轴压缩试验。在不同条件下,包括同时压缩的微针(MN)数量、压缩速度和压缩角度,获得了载荷-位移曲线。随后,计算了屈曲载荷和刚度,并观察了压缩过程中 MN 的变形。结果随着压缩 MN 的同时增加,每个 MN 的屈曲载荷和刚度明显降低。在单针压缩试验中,52 个 MN 的平均屈曲载荷和刚度分别为 0.211 ± 0.008 N 和 13.9 ± 1.3 N/mm,三种 MNA 之间没有差异。然而,在 MNA 中的 MN 之间,屈曲载荷和刚度存在明显差异。此外,不同 MNA 中同一位置的某些 MN 的屈曲载荷和刚度明显较低。与垂直压缩相比,倾斜压缩时的屈曲载荷和刚度明显降低。虽然测试评估的是 MNA 的机械性能,但测试结果可能因测试条件而异。结论:对构成 MNA 的单个 MN 进行压缩测试有助于评估 MN 的机械特性,确保 MNA 的质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pharmaceutics
Pharmaceutics Pharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
7.90
自引率
11.10%
发文量
2379
审稿时长
16.41 days
期刊介绍: Pharmaceutics (ISSN 1999-4923) is an open access journal which provides an advanced forum for the science and technology of pharmaceutics and biopharmaceutics. It publishes reviews, regular research papers, communications,  and short notes. Covered topics include pharmacokinetics, toxicokinetics, pharmacodynamics, pharmacogenetics and pharmacogenomics, and pharmaceutical formulation. Our aim is to encourage scientists to publish their experimental and theoretical details in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
RETRACTED: Khan et al. Norfloxacin Loaded Lipid Polymer Hybrid Nanoparticles for Oral Administration: Fabrication, Characterization, In Silico Modelling and Toxicity Evaluation. Pharmaceutics 2021, 13, 1632. Selection of Solubility Enhancement Technologies for S-892216, a Novel COVID-19 Drug Candidate. Silymarin and Silybin: Rejuvenating Traditional Remedies with Modern Delivery Strategies. Correction: Ortiz-Islas et al. Evolution of Alzheimer's Disease Therapeutics: From Conventional Drugs to Medicinal Plants, Immunotherapy, Microbiotherapy and Nanotherapy. Pharmaceutics 2025, 17, 128. Transcriptome-Guided Drug Repurposing Identifies Homoharringtonine (HHT) as a Candidate for Radiation-Induced Pulmonary Fibrosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1