Investigation of very high radiation hardness of 21 \(\varvec{\mu }\)m silicon self-biased detectors

IF 2.6 3区 物理与天体物理 Q2 PHYSICS, NUCLEAR The European Physical Journal A Pub Date : 2024-11-27 DOI:10.1140/epja/s10050-024-01454-9
Andrzej J. Kordyasz, Monika Paluch-Ferszt, Zygmunt Szefliński, Katarzyna Z. Krutul-Bitowska, Michał Kowalczyk, Andrzej Bednarek, Paweł J. Napiorkowski, Ł.ukasz Kordyasz, Grzegorz Gawlik, Konrad Krzyżak, Michał Gajewski
{"title":"Investigation of very high radiation hardness of 21 \\(\\varvec{\\mu }\\)m silicon self-biased detectors","authors":"Andrzej J. Kordyasz,&nbsp;Monika Paluch-Ferszt,&nbsp;Zygmunt Szefliński,&nbsp;Katarzyna Z. Krutul-Bitowska,&nbsp;Michał Kowalczyk,&nbsp;Andrzej Bednarek,&nbsp;Paweł J. Napiorkowski,&nbsp;Ł.ukasz Kordyasz,&nbsp;Grzegorz Gawlik,&nbsp;Konrad Krzyżak,&nbsp;Michał Gajewski","doi":"10.1140/epja/s10050-024-01454-9","DOIUrl":null,"url":null,"abstract":"<div><p>The radiation damage of 21 <span>\\(\\upmu \\)</span>m thick self-biased epitaxial <span>\\(\\varDelta E\\)</span> detectors were tested as a function of fluence of 90 MeV <span>\\(^{14}\\)</span>N ions. Technology of production and technique of measurements of <span>\\(\\varDelta E\\)</span> detectors were described. A new technique of soldering contact to thin detector is shown. In the present work the 21 <span>\\(\\upmu \\)</span>m thick self-biased detectors marked as d4 and d5 show proper operation with the fluence about 4<span>\\(\\cdot \\)</span>10<span>\\(^{15}\\)</span> <span>\\(\\hbox {ions/cm}^{2}\\)</span> and the fluence about 8<span>\\(\\cdot \\)</span>10<span>\\(^{15}\\)</span> <span>\\(\\hbox {ions/cm}^{2}\\)</span>, respectively. The charge collection efficiency of thin d5 <span>\\(\\varDelta E\\)</span> detector was increased about double at fluence about 8<span>\\(\\cdot \\)</span>10<span>\\(^{15}\\)</span> <span>\\(\\hbox {ions/cm}^{2}\\)</span>. The charge collection efficiency of thin d4 <span>\\(\\varDelta E\\)</span> detector was increased about 35<span>\\(\\%\\)</span> at fluence about 4<span>\\(\\cdot \\)</span>10<span>\\(^{15}\\)</span> <span>\\(\\hbox {ions/cm}^{2}\\)</span> followed decrease about 70<span>\\(\\%\\)</span> of detector counting rate registration from fluence 9.1<span>\\(\\cdot \\)</span>10<span>\\(^{15}\\)</span> <span>\\(\\hbox {ions/cm}^{2}\\)</span> to fluence about 5<span>\\(\\cdot \\)</span>10<span>\\(^{16}\\)</span> <span>\\(\\hbox {ions/cm}^{2}\\)</span> due to partially removing of Al evaporated contact from detector surface as an effect of heavy ion irradiation. Increase of charge collection efficiency of thin self-biased detectors manufactured by the low-temperature technique was probably produced by increasing of build-in potential as an effect of activate carrier concentration of boron ions in epitaxial layer by heavy ion irradiation.</p></div>","PeriodicalId":786,"journal":{"name":"The European Physical Journal A","volume":"60 11","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European Physical Journal A","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1140/epja/s10050-024-01454-9","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

The radiation damage of 21 \(\upmu \)m thick self-biased epitaxial \(\varDelta E\) detectors were tested as a function of fluence of 90 MeV \(^{14}\)N ions. Technology of production and technique of measurements of \(\varDelta E\) detectors were described. A new technique of soldering contact to thin detector is shown. In the present work the 21 \(\upmu \)m thick self-biased detectors marked as d4 and d5 show proper operation with the fluence about 4\(\cdot \)10\(^{15}\) \(\hbox {ions/cm}^{2}\) and the fluence about 8\(\cdot \)10\(^{15}\) \(\hbox {ions/cm}^{2}\), respectively. The charge collection efficiency of thin d5 \(\varDelta E\) detector was increased about double at fluence about 8\(\cdot \)10\(^{15}\) \(\hbox {ions/cm}^{2}\). The charge collection efficiency of thin d4 \(\varDelta E\) detector was increased about 35\(\%\) at fluence about 4\(\cdot \)10\(^{15}\) \(\hbox {ions/cm}^{2}\) followed decrease about 70\(\%\) of detector counting rate registration from fluence 9.1\(\cdot \)10\(^{15}\) \(\hbox {ions/cm}^{2}\) to fluence about 5\(\cdot \)10\(^{16}\) \(\hbox {ions/cm}^{2}\) due to partially removing of Al evaporated contact from detector surface as an effect of heavy ion irradiation. Increase of charge collection efficiency of thin self-biased detectors manufactured by the low-temperature technique was probably produced by increasing of build-in potential as an effect of activate carrier concentration of boron ions in epitaxial layer by heavy ion irradiation.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
21 \(\varvec{\mu }\)m 硅自偏压探测器的超高辐射硬度研究
作为90 MeV \(^{14}\)N 离子通量的函数,测试了21 \(\upmu\)m 厚的自偏压外延 \(\varDelta E\) 探测器的辐射损伤。描述了探测器的生产技术和测量技术。展示了一种将接触焊接到薄探测器上的新技术。在目前的工作中,标为d4和d5的21(upmu)m厚的自偏压探测器分别在4(cdot)10(^{15}\)(\hbox {ions/cm}^{2}\) 和8(cdot)10(^{15}\)(\hbox {ions/cm}^{2}\) 左右的通量下正常工作。在大约8(\cdot \)10(^{15})(\hbox {ions/cm}^{2}\ )的通量下,薄型d5(\varDelta E\ )探测器的电荷收集效率提高了大约一倍。在大约4(cdot)10(^{15})(hbox {ions/cm}^{2}\) 的通量下,薄d4(varDelta E\) 探测器的电荷收集效率提高了大约35(%),而从通量9开始,探测器的计数登记率下降了大约70(%)。1(\cdot)10(^{15})(\hbox {ions/cm}^{2}\) 到大约 5(\cdot)10(^{16})(\hbox {ions/cm}^{2}\) 的通量,这是由于重离子辐照的影响导致探测器表面的铝蒸发接触部分去除。低温技术制造的薄型自偏压探测器电荷收集效率的提高可能是由于重离子辐照激活了外延层中硼离子的载流子浓度,从而提高了内置电位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
The European Physical Journal A
The European Physical Journal A 物理-物理:核物理
CiteScore
5.00
自引率
18.50%
发文量
216
审稿时长
3-8 weeks
期刊介绍: Hadron Physics Hadron Structure Hadron Spectroscopy Hadronic and Electroweak Interactions of Hadrons Nonperturbative Approaches to QCD Phenomenological Approaches to Hadron Physics Nuclear and Quark Matter Heavy-Ion Collisions Phase Diagram of the Strong Interaction Hard Probes Quark-Gluon Plasma and Hadronic Matter Relativistic Transport and Hydrodynamics Compact Stars Nuclear Physics Nuclear Structure and Reactions Few-Body Systems Radioactive Beams Electroweak Interactions Nuclear Astrophysics Article Categories Letters (Open Access) Regular Articles New Tools and Techniques Reviews.
期刊最新文献
Erratum to: Studies of the Giant Dipole Resonance in \(^{27}\)Al, \(^{40}\)Ca, \(^{56}\)Fe, \(^{58}\)Ni and \(^{208}\)Pb with high energy-resolution inelastic proton scattering under \(0^{\circ }\) Study of the log-third-difference method for the computation of even-odd staggering in fission yields First lifetime measurement of the \(9^{-}\) isomer in \(^{92}\)Nb Ab initio description of monopole resonances in light- and medium-mass nuclei Flow and equation of state of nuclear matter at \({\varvec{E_\textrm{kin}/A=0.25}}\)–1.5 GeV with the SMASH transport approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1