Development of Recombinant Antibodies and Its Application in Immunomagnetic Separation-Based Rapid Detection of Vibrio cholerae in Aquatic Environments.
{"title":"Development of Recombinant Antibodies and Its Application in Immunomagnetic Separation-Based Rapid Detection of <i>Vibrio cholerae</i> in Aquatic Environments.","authors":"Haiyang Zhang, Quan Wang, Haoxiang Zhuang, Qiu Lin, Wenchao Wang, Fangyu Ye, Saqib Nawaz, Jiangang Hu, Cuiqin Huang, Huifang Yin, Weidong Sun, Xiangan Han, Wei Jiang","doi":"10.4014/jmb.2405.05003","DOIUrl":null,"url":null,"abstract":"<p><p>Cholera caused by <i>Vibrio cholerae</i> remains a major public health concern in many countries. The greatest obstacle to detection of <i>V. cholerae</i> contamination in drinking water or aquatic environments mainly relates to sample preparation steps, especially the enrichment step. In this study, immunomagnetic separation methods were developed based on sequence-defined recombinant antibodies (rAbs) against <i>V. cholerae</i>, then used for the specific and efficient enrichment of <i>V. cholerae</i> in water samples. Using the variable region genes of the anti-<i>V. cholerae</i> monoclonal antibodies (mAbs) 5F2, the full-length IgG rAbs (R5F2) were produced using mammalian human embryonic kidney 293T cells. Two antibodies, 5F2 and R5F2, were used to prepare immunomagnetic beads (IMBs), and their capture efficiencies (CEs) were evaluated. The results showed that 0.4 mg of 5F2-IMBs and R5F2-IMBs exhibited good CEs (96.0% and 75.9%, respectively) against <i>V. cholerae</i> within 40 min. The IMBs could still effectively capture <i>V. cholerae</i> in large-volume reaction systems (5 ml to 25 ml). The CEs of 5F2-IMBs and R5F2-IMBs ranged from 90.2% to 70.7% and 65.1% to 44.2%, respectively. Furthermore, 5F2-IMBs and R5F2-IMBs did not show significant cross-reactivity with other bacteria and exhibited high specificity. When R5F2-IMS was used in combination with quantitative real-time PCR, the detection limit was approximately 5 colony-forming units/25 ml after enrichment for 4 h. Our results suggest that the rAbs produced herein could provide useful alternatives to traditional hybridoma-based antibodies for accurate detection of <i>V. cholerae</i> in food safety and environmental monitoring.</p>","PeriodicalId":16481,"journal":{"name":"Journal of microbiology and biotechnology","volume":"34 11","pages":"2266-2278"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11637869/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of microbiology and biotechnology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.4014/jmb.2405.05003","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Cholera caused by Vibrio cholerae remains a major public health concern in many countries. The greatest obstacle to detection of V. cholerae contamination in drinking water or aquatic environments mainly relates to sample preparation steps, especially the enrichment step. In this study, immunomagnetic separation methods were developed based on sequence-defined recombinant antibodies (rAbs) against V. cholerae, then used for the specific and efficient enrichment of V. cholerae in water samples. Using the variable region genes of the anti-V. cholerae monoclonal antibodies (mAbs) 5F2, the full-length IgG rAbs (R5F2) were produced using mammalian human embryonic kidney 293T cells. Two antibodies, 5F2 and R5F2, were used to prepare immunomagnetic beads (IMBs), and their capture efficiencies (CEs) were evaluated. The results showed that 0.4 mg of 5F2-IMBs and R5F2-IMBs exhibited good CEs (96.0% and 75.9%, respectively) against V. cholerae within 40 min. The IMBs could still effectively capture V. cholerae in large-volume reaction systems (5 ml to 25 ml). The CEs of 5F2-IMBs and R5F2-IMBs ranged from 90.2% to 70.7% and 65.1% to 44.2%, respectively. Furthermore, 5F2-IMBs and R5F2-IMBs did not show significant cross-reactivity with other bacteria and exhibited high specificity. When R5F2-IMS was used in combination with quantitative real-time PCR, the detection limit was approximately 5 colony-forming units/25 ml after enrichment for 4 h. Our results suggest that the rAbs produced herein could provide useful alternatives to traditional hybridoma-based antibodies for accurate detection of V. cholerae in food safety and environmental monitoring.
期刊介绍:
The Journal of Microbiology and Biotechnology (JMB) is a monthly international journal devoted to the advancement and dissemination of scientific knowledge pertaining to microbiology, biotechnology, and related academic disciplines. It covers various scientific and technological aspects of Molecular and Cellular Microbiology, Environmental Microbiology and Biotechnology, Food Biotechnology, and Biotechnology and Bioengineering (subcategories are listed below). Launched in March 1991, the JMB is published by the Korean Society for Microbiology and Biotechnology (KMB) and distributed worldwide.