Efficient contact-based registration for minimally invasive anterior hip arthroplasty

IF 4.9 2区 医学 Q1 ENGINEERING, BIOMEDICAL Biomedical Signal Processing and Control Pub Date : 2024-11-30 DOI:10.1016/j.bspc.2024.107216
Xianzhong Xie , Mingzhu Zhu , Weijian Chen , Jie Xu , Bingwei He
{"title":"Efficient contact-based registration for minimally invasive anterior hip arthroplasty","authors":"Xianzhong Xie ,&nbsp;Mingzhu Zhu ,&nbsp;Weijian Chen ,&nbsp;Jie Xu ,&nbsp;Bingwei He","doi":"10.1016/j.bspc.2024.107216","DOIUrl":null,"url":null,"abstract":"<div><div>This paper introduces an efficient contact-based registration method for minimally invasive anterior hip arthroplasty. Unlike existing methods that involve radiation exposure, implanted screws, or tedious point collection, our method requires only one contact within the acetabulum and two contacts on the landmarks. Inspired by the probe’s ball tip, we define a unique position, named <em>stable point</em>, to decouple translation from the overall transformation. The stable point in patient space is easily acquired by our tool, simplifying translation estimation to compute the stable point in image space. We present a fast computation method based on dichotomic search. After aligning the stable points, we introduce two bone landmarks for rotation estimation in a center-aware manner. Additionally, a deltille grid position-sensing (DGPS) marker is used to improve instrument tracking robustness. Experiments were conducted to evaluate the performance of our methods, demonstrating an average accuracy of <span><math><mrow><mn>0</mn><mo>.</mo><mn>16</mn><mo>±</mo><mn>0</mn><mo>.</mo><mn>03</mn><mspace></mspace><mi>mm</mi></mrow></math></span> for instrument tracking and <span><math><mrow><mn>1</mn><mo>.</mo><mn>41</mn><mo>±</mo><mn>0</mn><mo>.</mo><mn>16</mn><mspace></mspace><mi>mm</mi></mrow></math></span> for registration. Moreover, the entire process takes less than 1 minute. Results suggest that our method has significant potential for clinical application.</div></div>","PeriodicalId":55362,"journal":{"name":"Biomedical Signal Processing and Control","volume":"102 ","pages":"Article 107216"},"PeriodicalIF":4.9000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Signal Processing and Control","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1746809424012746","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This paper introduces an efficient contact-based registration method for minimally invasive anterior hip arthroplasty. Unlike existing methods that involve radiation exposure, implanted screws, or tedious point collection, our method requires only one contact within the acetabulum and two contacts on the landmarks. Inspired by the probe’s ball tip, we define a unique position, named stable point, to decouple translation from the overall transformation. The stable point in patient space is easily acquired by our tool, simplifying translation estimation to compute the stable point in image space. We present a fast computation method based on dichotomic search. After aligning the stable points, we introduce two bone landmarks for rotation estimation in a center-aware manner. Additionally, a deltille grid position-sensing (DGPS) marker is used to improve instrument tracking robustness. Experiments were conducted to evaluate the performance of our methods, demonstrating an average accuracy of 0.16±0.03mm for instrument tracking and 1.41±0.16mm for registration. Moreover, the entire process takes less than 1 minute. Results suggest that our method has significant potential for clinical application.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Biomedical Signal Processing and Control
Biomedical Signal Processing and Control 工程技术-工程:生物医学
CiteScore
9.80
自引率
13.70%
发文量
822
审稿时长
4 months
期刊介绍: Biomedical Signal Processing and Control aims to provide a cross-disciplinary international forum for the interchange of information on research in the measurement and analysis of signals and images in clinical medicine and the biological sciences. Emphasis is placed on contributions dealing with the practical, applications-led research on the use of methods and devices in clinical diagnosis, patient monitoring and management. Biomedical Signal Processing and Control reflects the main areas in which these methods are being used and developed at the interface of both engineering and clinical science. The scope of the journal is defined to include relevant review papers, technical notes, short communications and letters. Tutorial papers and special issues will also be published.
期刊最新文献
Efficient contact-based registration for minimally invasive anterior hip arthroplasty A dense kernel point convolutional neural network for chronic liver disease classification with hybrid chaotic slime mould and giant trevally optimizer A study of complex network features for electrocardiograms and its Applications in atrial fibrillation recognition Frequency information enhanced half instance normalization network for denoising electrocardiograms Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1