Formaldehyde Levels and the Indoor Air Quality of an Anatomy Dissection Hall with Different Ventilation Setups.

IF 2.3 Q2 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Environmental Health Insights Pub Date : 2024-11-26 eCollection Date: 2024-01-01 DOI:10.1177/11786302241301590
Ganesh Handady, Anne Dsouza, Vanishri Nayak, Joseph Abraham
{"title":"Formaldehyde Levels and the Indoor Air Quality of an Anatomy Dissection Hall with Different Ventilation Setups.","authors":"Ganesh Handady, Anne Dsouza, Vanishri Nayak, Joseph Abraham","doi":"10.1177/11786302241301590","DOIUrl":null,"url":null,"abstract":"<p><p>During anatomy dissection, the release of formaldehyde (FA) from cadavers and embalming fluids can negatively affect the well-being of students and staff. The exposure of students, staff, and technicians to FA in the dissection hall is a concern. To address this issue, a study measured the FA and air quality (CO<sub>2</sub> and Total Volatile Organic Compounds- TVOC) with different ventilation setups: natural, fan-based, and air-conditioned. The FA levels and the indoor air quality at the breathing zone were estimated using an air conditioning (AC), fan-based, and naturally ventilated setup. The FA, CO<sub>2</sub>, and TVOC levels were calculated at the cadavers' head and toe ends, in the pathway, and between the dissection tables. The FA, CO<sub>2</sub>, and TVOC levels were higher near the cadaver and lower in the pathway and between the tables, regardless of the type of ventilation used. Fan-based ventilation had the lowest mean FA, CO<sub>2</sub>, and TVOC levels compared to AC and natural ventilation. However, there was no significant difference in these levels between the ventilation types, except for the toe-ends of the cadavers (<i>P</i> < .05), where the toe-end farther from the AC vents had higher levels. The study suggests that areas away from the source of ventilation in the anatomy dissection hall are at risk of having lower air quality. Therefore, in addition to selecting an appropriate ventilation system, placing the donor bodies near the source of ventilation would help optimize FA levels and improve indoor air quality for better working conditions suitable for students and staff.</p>","PeriodicalId":11827,"journal":{"name":"Environmental Health Insights","volume":"18 ","pages":"11786302241301590"},"PeriodicalIF":2.3000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11603455/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Health Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/11786302241301590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

During anatomy dissection, the release of formaldehyde (FA) from cadavers and embalming fluids can negatively affect the well-being of students and staff. The exposure of students, staff, and technicians to FA in the dissection hall is a concern. To address this issue, a study measured the FA and air quality (CO2 and Total Volatile Organic Compounds- TVOC) with different ventilation setups: natural, fan-based, and air-conditioned. The FA levels and the indoor air quality at the breathing zone were estimated using an air conditioning (AC), fan-based, and naturally ventilated setup. The FA, CO2, and TVOC levels were calculated at the cadavers' head and toe ends, in the pathway, and between the dissection tables. The FA, CO2, and TVOC levels were higher near the cadaver and lower in the pathway and between the tables, regardless of the type of ventilation used. Fan-based ventilation had the lowest mean FA, CO2, and TVOC levels compared to AC and natural ventilation. However, there was no significant difference in these levels between the ventilation types, except for the toe-ends of the cadavers (P < .05), where the toe-end farther from the AC vents had higher levels. The study suggests that areas away from the source of ventilation in the anatomy dissection hall are at risk of having lower air quality. Therefore, in addition to selecting an appropriate ventilation system, placing the donor bodies near the source of ventilation would help optimize FA levels and improve indoor air quality for better working conditions suitable for students and staff.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Environmental Health Insights
Environmental Health Insights PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
3.20
自引率
22.20%
发文量
97
审稿时长
8 weeks
期刊最新文献
Multidrug-Resistant Bacteria in Aquaculture Systems in Accra, Ghana. Formaldehyde Levels and the Indoor Air Quality of an Anatomy Dissection Hall with Different Ventilation Setups. Impact of Rising Summer Temperatures on Government Sector Tertiary Care Emergency Centers: Addressing Heatstroke and Associated Death Rates in Karachi, Pakistan. Investigating the Presence and Levels of Some Selected Chemical Parameters in Borehole Water of Ga-Matlala in Limpopo Province, South Africa: Determining the Potential Risks. Zoonotic and Food-Related Hazards Due to Hepatitis A and E in Africa: A Systematic Review and Meta-Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1