Safety assessment of microwave ablation in sheep vertebral bodies.

IF 3 3区 医学 Q2 ONCOLOGY International Journal of Hyperthermia Pub Date : 2024-01-01 Epub Date: 2024-11-28 DOI:10.1080/02656736.2024.2434607
Hendricus Nijland, Jinwen Zhu, Thomas Kwee, Ding-Jun Hao, Paul Jutte
{"title":"Safety assessment of microwave ablation in sheep vertebral bodies.","authors":"Hendricus Nijland, Jinwen Zhu, Thomas Kwee, Ding-Jun Hao, Paul Jutte","doi":"10.1080/02656736.2024.2434607","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Spine is the most common location for bone metastases. Microwave ablation (MWA) is a technique for minimally invasive tumor treatment. The aim of the current study was to determine whether MWA is a safe option for treatment in vertebral bodies and to gain data on the amount of cortical insulation in the spine.</p><p><strong>Method: </strong>MWA was applied with different settings for power and time in both in- and ex-vivo sheep vertebral bodies. Safety was evaluated by temperature measurements at critical surrounding structures (e.g. spinal cord, nerve root). Furthermore, the distribution of heat through the bone at 5 mm from the ablation needle was measured and compared to the temperature at the posterior wall.</p><p><strong>Results: </strong>An effect of cortical insulation in the spine was found, for ablations with 20-30 and 50 W (<i>p</i> < 0.01). Ablations with wattage levels of 40-50 W almost instantly led to temperatures over 60 °C at the posterior wall. The temperature remained below 60 °C for 4 min in ex-vivo ablations with 20 and 30 W. However, in the in-vivo experiment paralysis was frequently seen (10/12 sheep) in lower wattages (20-30 W) as well and the experiment was therefore terminated.</p><p><strong>Conclusion: </strong>MWA is an effective approach for local bone destruction in the spine. However, given the high risk of complications, caution is advised for treatment in vertebral bodies without better local distribution accuracy. Since cortical insulation appears insufficient to protect the spinal canal from excess heat, MWA involves a risk of paralysis.</p>","PeriodicalId":14137,"journal":{"name":"International Journal of Hyperthermia","volume":"41 1","pages":"2434607"},"PeriodicalIF":3.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Hyperthermia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02656736.2024.2434607","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Spine is the most common location for bone metastases. Microwave ablation (MWA) is a technique for minimally invasive tumor treatment. The aim of the current study was to determine whether MWA is a safe option for treatment in vertebral bodies and to gain data on the amount of cortical insulation in the spine.

Method: MWA was applied with different settings for power and time in both in- and ex-vivo sheep vertebral bodies. Safety was evaluated by temperature measurements at critical surrounding structures (e.g. spinal cord, nerve root). Furthermore, the distribution of heat through the bone at 5 mm from the ablation needle was measured and compared to the temperature at the posterior wall.

Results: An effect of cortical insulation in the spine was found, for ablations with 20-30 and 50 W (p < 0.01). Ablations with wattage levels of 40-50 W almost instantly led to temperatures over 60 °C at the posterior wall. The temperature remained below 60 °C for 4 min in ex-vivo ablations with 20 and 30 W. However, in the in-vivo experiment paralysis was frequently seen (10/12 sheep) in lower wattages (20-30 W) as well and the experiment was therefore terminated.

Conclusion: MWA is an effective approach for local bone destruction in the spine. However, given the high risk of complications, caution is advised for treatment in vertebral bodies without better local distribution accuracy. Since cortical insulation appears insufficient to protect the spinal canal from excess heat, MWA involves a risk of paralysis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
绵羊椎体微波消融的安全性评估。
背景:脊柱是骨转移最常见的部位。微波消融(MWA)是一种微创肿瘤治疗技术。当前研究的目的是确定MWA是否是椎体治疗的安全选择,并获得脊柱皮质绝缘量的数据。方法:在羊体内和离体椎体中采用不同功率和时间设置的MWA。通过测量周围关键结构(如脊髓、神经根)的温度来评估安全性。此外,测量了距消融针5mm处的骨热分布,并与后壁温度进行了比较。结论:MWA是治疗脊柱局部骨破坏的有效方法。结论:MWA是治疗脊柱局部骨破坏的有效方法。然而,考虑到并发症的高风险,建议在没有更好的局部分布准确性的椎体中谨慎治疗。由于皮质绝缘不足以保护椎管免受过热的影响,MWA有瘫痪的危险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.90
自引率
12.90%
发文量
153
审稿时长
6-12 weeks
期刊介绍: The International Journal of Hyperthermia
期刊最新文献
Nomogram for predicting the efficacy of high-intensity focused ultrasound ablation for uterine fibroids based on oxytocin experimentation and ultrasonographic features: a retrospective single-center study. Thyroid nodule rupture after thermal ablation for benign thyroid nodules: incidence, risk factors, and clinical management. A translational review of hyperthermia biology. Osteoarthritis-related knee pain: MRI-guided focused ultrasound ablation treatment. The role of HSPA14 in breast cancer: implications for tumorigenesis, immune response modulation, and personalized therapies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1