Ultra-high gradient performance 3-Tesla MRI for super-fast and high-quality prostate imaging: initial experience.

IF 4.1 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Insights into Imaging Pub Date : 2024-11-29 DOI:10.1186/s13244-024-01862-x
Leon M Bischoff, Christoph Endler, Philipp Krausewitz, Joerg Ellinger, Niklas Klümper, Alexander Isaak, Narine Mesropyan, Dmitrij Kravchenko, Sebastian Nowak, Daniel Kuetting, Alois M Sprinkart, Petra Mürtz, Claus C Pieper, Ulrike Attenberger, Julian A Luetkens
{"title":"Ultra-high gradient performance 3-Tesla MRI for super-fast and high-quality prostate imaging: initial experience.","authors":"Leon M Bischoff, Christoph Endler, Philipp Krausewitz, Joerg Ellinger, Niklas Klümper, Alexander Isaak, Narine Mesropyan, Dmitrij Kravchenko, Sebastian Nowak, Daniel Kuetting, Alois M Sprinkart, Petra Mürtz, Claus C Pieper, Ulrike Attenberger, Julian A Luetkens","doi":"10.1186/s13244-024-01862-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To implement and evaluate a super-fast and high-quality biparametric MRI (bpMRI) protocol for prostate imaging acquired at a new ultra-high gradient 3.0-T MRI system.</p><p><strong>Methods: </strong>Participants with clinically suspected prostate cancer prospectively underwent a multiparametric MRI (mpMRI) on a new 3.0-T MRI scanner (maximum gradient strength: 200 mT/m, maximum slew rate: 200 T/m/s). The bpMRI protocol was extracted from the full mpMRI protocol, including axial T2-weighted and diffusion-weighted (DWI) sequences (b0/800, b1500). Overall image quality was rated by two readers on a five-point Likert scale from (1) non-diagnostic to (5) excellent. PI-RADS 2.1 scores were assessed by three readers separately for the bpMRI and mpMRI protocols. Cohen's and Fleiss' κ were calculated for PI-RADS agreement between protocols and interrater reliability between readers, respectively.</p><p><strong>Results: </strong>Seventy-seven male participants (mean age, 66 ± 8 years) were included. Acquisition time of the bpMRI protocol was reduced by 62% (bpMRI: 5 min, 33 ± 21 s; mpMRI: 14 min, 50 ± 42 s). The bpMRI protocol showed excellent overall image quality for both the T2-weighted (median score both readers: 5 [IQR: 4-5]) and DWI (b1500) sequence (median score reader 1: 4 [IQR: 4-5]; reader 2: 4 [IQR: 4-4]). PI-RADS score agreement between protocols was excellent (Cohen's κ range: 0.91-0.95 [95% CI: 0.89, 0.99]) with an overall good interrater reliability (Fleiss' κ, 0.86 [95% CI: 0.80, 0.92]).</p><p><strong>Conclusion: </strong>Ultra-high gradient MRI allows the establishment of a high-quality and rapidly acquired bpMRI with high PI-RADS agreement to a full mpMRI protocol.</p><p><strong>Trials registration: </strong>Clinicaltrials.gov, NCT06244680, Registered 06 February 2024, retrospectively registered, https://classic.</p><p><strong>Clinicaltrials: </strong>gov/ct2/show/NCT06244680 .</p><p><strong>Critical relevance statement: </strong>A novel 3.0-Tesla MRI system with an ultra-high gradient performance enabled high-quality biparametric prostate MRI in 5.5 min while achieving excellent PI-RADS agreement with a standard multiparametric protocol.</p><p><strong>Key points: </strong>Multi- and biparametric prostate MRIs were prospectively acquired utilizing a maximum gradient of 200 mT/m. Super-fast biparametric MRIs showed excellent image quality and had high PI-RADS agreement with multiparametric MRIs. Implementation of high gradient MRI in clinical routine allows accelerated and high-quality biparametric prostate examinations.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"15 1","pages":"287"},"PeriodicalIF":4.1000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11607256/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-024-01862-x","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To implement and evaluate a super-fast and high-quality biparametric MRI (bpMRI) protocol for prostate imaging acquired at a new ultra-high gradient 3.0-T MRI system.

Methods: Participants with clinically suspected prostate cancer prospectively underwent a multiparametric MRI (mpMRI) on a new 3.0-T MRI scanner (maximum gradient strength: 200 mT/m, maximum slew rate: 200 T/m/s). The bpMRI protocol was extracted from the full mpMRI protocol, including axial T2-weighted and diffusion-weighted (DWI) sequences (b0/800, b1500). Overall image quality was rated by two readers on a five-point Likert scale from (1) non-diagnostic to (5) excellent. PI-RADS 2.1 scores were assessed by three readers separately for the bpMRI and mpMRI protocols. Cohen's and Fleiss' κ were calculated for PI-RADS agreement between protocols and interrater reliability between readers, respectively.

Results: Seventy-seven male participants (mean age, 66 ± 8 years) were included. Acquisition time of the bpMRI protocol was reduced by 62% (bpMRI: 5 min, 33 ± 21 s; mpMRI: 14 min, 50 ± 42 s). The bpMRI protocol showed excellent overall image quality for both the T2-weighted (median score both readers: 5 [IQR: 4-5]) and DWI (b1500) sequence (median score reader 1: 4 [IQR: 4-5]; reader 2: 4 [IQR: 4-4]). PI-RADS score agreement between protocols was excellent (Cohen's κ range: 0.91-0.95 [95% CI: 0.89, 0.99]) with an overall good interrater reliability (Fleiss' κ, 0.86 [95% CI: 0.80, 0.92]).

Conclusion: Ultra-high gradient MRI allows the establishment of a high-quality and rapidly acquired bpMRI with high PI-RADS agreement to a full mpMRI protocol.

Trials registration: Clinicaltrials.gov, NCT06244680, Registered 06 February 2024, retrospectively registered, https://classic.

Clinicaltrials: gov/ct2/show/NCT06244680 .

Critical relevance statement: A novel 3.0-Tesla MRI system with an ultra-high gradient performance enabled high-quality biparametric prostate MRI in 5.5 min while achieving excellent PI-RADS agreement with a standard multiparametric protocol.

Key points: Multi- and biparametric prostate MRIs were prospectively acquired utilizing a maximum gradient of 200 mT/m. Super-fast biparametric MRIs showed excellent image quality and had high PI-RADS agreement with multiparametric MRIs. Implementation of high gradient MRI in clinical routine allows accelerated and high-quality biparametric prostate examinations.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超高梯度性能3-特斯拉MRI超快速高质量前列腺成像:初步体验。
目的:在新型超高梯度3.0 t MRI系统上实现并评估一种超快速、高质量的双参数MRI (bpMRI)摄护腺成像方案。方法:临床怀疑前列腺癌的参与者在新的3.0 T MRI扫描仪(最大梯度强度:200 mT/m,最大旋转速率:200 T/m/s)上前瞻性地接受了多参数MRI (mpMRI)检查。从完整的mpMRI协议中提取bpMRI协议,包括轴向t2加权和弥散加权(DWI)序列(b0/800, b1500)。整体图像质量由两位读者在李克特五分制量表上进行评分,从(1)非诊断性到(5)优秀。PI-RADS 2.1评分由三名读者分别对bpMRI和mpMRI方案进行评估。分别计算协议间PI-RADS一致性和阅读器间互读器可靠性的Cohen’s和Fleiss’s κ。结果:纳入男性77例,平均年龄66±8岁。bpMRI方案采集时间缩短62% (bpMRI: 5 min, 33±21 s;mpMRI: 14分钟,50±42秒)。bpMRI方案显示t2加权(阅读器中位数评分:5 [IQR: 4-5])和DWI (b1500)序列(阅读器中位数评分1:4 [IQR: 4-5];[IQR: 4-4])。各方案之间的PI-RADS评分一致性非常好(Cohen's κ范围:0.91-0.95 [95% CI: 0.89, 0.99]),总体上具有良好的互信度(Fleiss' s κ, 0.86 [95% CI: 0.80, 0.92])。结论:超高梯度MRI可以建立高质量和快速获得的bpMRI,具有高PI-RADS一致性,符合完整的mpMRI方案。试验注册:Clinicaltrials.gov, NCT06244680,注册日期:2024年2月6日,回顾性注册,https://classic.Clinicaltrials: gov/ct2/show/NCT06244680。关键相关性声明:一种新型3.0-Tesla MRI系统,具有超高梯度性能,可在5.5分钟内实现高质量的双参数前列腺MRI,同时通过标准的多参数协议实现出色的PI-RADS协议。重点:利用200 mT/m的最大梯度,前瞻性地获得多参数和双参数前列腺mri。超快速双参数核磁共振成像图像质量优异,PI-RADS与多参数核磁共振成像具有较高的一致性。在临床常规中实施高梯度MRI可以加速和高质量的双参数前列腺检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Insights into Imaging
Insights into Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
7.30
自引率
4.30%
发文量
182
审稿时长
13 weeks
期刊介绍: Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere! I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe. Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy. A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field. I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly. The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members. The journal went open access in 2012, which means that all articles published since then are freely available online.
期刊最新文献
Radiofrequency ablation for peribiliary hepatocellular carcinoma: propensity score matching analysis. A machine learning model based on preoperative multiparametric quantitative DWI can effectively predict the survival and recurrence risk of pancreatic ductal adenocarcinoma. Assessing the perceived impact of ESOR training programs on radiologists' professional development. Charting a sustainable future in radiology: evaluating radiologists' knowledge, attitudes, and practices toward environmental responsibility. Diagnosis of adult midgut malrotation in CT: sign of absent retromesenteric duodenum reliable.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1