{"title":"Flange Size Matters: A Comparative Pilot Study of the Flange FITS<sup>TM</sup> Guide Versus Traditional Sizing Methods.","authors":"Lisa A Anders, Jeanette Mesite Frem, Thomas P McCoy","doi":"10.1177/08903344241296036","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pumping is a common practice in the United States, but it can be uncomfortable and lead to concerns about milk supply. The fit of the flange, or breast shield, used while pumping can contribute to or alleviate these problems. Flanges are available in a wide variety of sizes, and there are inconsistencies in guidance provided by healthcare providers and pump manufacturers for parents choosing a size. There have been no studies comparing different methods of sizing in terms of comfort and milk output.</p><p><strong>Research aims: </strong>The aim of this research was to examine differences in milk output and comfort using two methods of flange sizing.</p><p><strong>Method: </strong>A within-subject cross-over design with a convenience sample of parents exclusively feeding their own human milk was used to compare comfort and milk yield between using smaller-fit and standard-fit flanges. Participants pumped for 1 week with each set of flanges and recorded milk output and comfort outcome measures. Data were collected on participant demographics, nipple measurements, and flange sizes used.</p><p><strong>Results: </strong>When compared to the newer small-size fitting, participants using the standard fit flanges had significantly less milk output (mean difference = -15.0 g, 95% CI [-25.0, -5.0], <i>d</i> = -0.51, <i>p</i> = 0.004) and less comfort (mean difference = -1.2, 95% CI [-1.6, -0.91], <i>d</i> = -1.23, <i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>Flange fitting is a process that should be individualized to the patient and may require a trial of one or more sizes during a pumping session. Smaller sizes determined using this individualized process and starting with nipple tip measurement may be used without compromising milk output or comfort.</p>","PeriodicalId":15948,"journal":{"name":"Journal of Human Lactation","volume":" ","pages":"8903344241296036"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Human Lactation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08903344241296036","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Pumping is a common practice in the United States, but it can be uncomfortable and lead to concerns about milk supply. The fit of the flange, or breast shield, used while pumping can contribute to or alleviate these problems. Flanges are available in a wide variety of sizes, and there are inconsistencies in guidance provided by healthcare providers and pump manufacturers for parents choosing a size. There have been no studies comparing different methods of sizing in terms of comfort and milk output.
Research aims: The aim of this research was to examine differences in milk output and comfort using two methods of flange sizing.
Method: A within-subject cross-over design with a convenience sample of parents exclusively feeding their own human milk was used to compare comfort and milk yield between using smaller-fit and standard-fit flanges. Participants pumped for 1 week with each set of flanges and recorded milk output and comfort outcome measures. Data were collected on participant demographics, nipple measurements, and flange sizes used.
Results: When compared to the newer small-size fitting, participants using the standard fit flanges had significantly less milk output (mean difference = -15.0 g, 95% CI [-25.0, -5.0], d = -0.51, p = 0.004) and less comfort (mean difference = -1.2, 95% CI [-1.6, -0.91], d = -1.23, p < 0.001).
Conclusion: Flange fitting is a process that should be individualized to the patient and may require a trial of one or more sizes during a pumping session. Smaller sizes determined using this individualized process and starting with nipple tip measurement may be used without compromising milk output or comfort.
期刊介绍:
Committed to the promotion of diversity and equity in all our policies and practices, our aims are:
To provide our readers and the international communities of clinicians, educators and scholars working in the field of lactation with current and quality-based evidence, from a broad array of disciplines, including the medical sciences, basic sciences, social sciences and the humanities.
To provide student and novice researchers, as well as, researchers whose native language is not English, with expert editorial guidance while preparing their work for publication in JHL.
In each issue, the Journal of Human Lactation publishes original research, original theoretical and conceptual articles, discussions of policy and practice issues, and the following special features:
Advocacy: A column that discusses a ‘hot’ topic in lactation advocacy
About Research: A column focused on an in-depth discussion of a different research topic each issue
Lactation Newsmakers: An interview with a widely-recognized outstanding expert in the field from around the globe
Research Commentary: A brief discussion of the issues raised in a specific research article published in the current issue
Book review(s): Reviews written by content experts about relevant new publications
International News Briefs: From major international lactation organizations.