Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study.

IF 1.5 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Ultrasonography Pub Date : 2024-11-30 eCollection Date: 2024-12-01 DOI:10.15557/jou.2024.0024
Anna Tomaszkiewicz, Piotr Szymański, Piotr Kruczek
{"title":"Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study.","authors":"Anna Tomaszkiewicz, Piotr Szymański, Piotr Kruczek","doi":"10.15557/jou.2024.0024","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Thrombosis is a common complication of umbilical artery catheterization. The purpose of this study was to compare the novel ultralow umbilical artery catheter position (catheter tip at the junction of the umbilical and internal iliac arteries) versus the conventional high umbilical artery catheter position (tip in the aorta, above the diaphragm) for the incidence of thrombosis.</p><p><strong>Study design: </strong>This study was conducted in a nonacademic, tertiary-referral neonatal center. The insertion and placement of the umbilical artery catheter was performed under continuous ultrasound guidance. Serial ultrasound examinations were performed to identify thrombosis in 38 consecutive newborns with an umbilical artery catheter placed in the novel ultralow position. The control group consisted of 50 infants with an umbilical artery catheter placed in the standard position.</p><p><strong>Results: </strong>The incidence of thrombosis requiring anticoagulant treatment was 22% in neonates with an umbilical artery catheter in the standard position. No thrombosis was detected in those with an umbilical artery catheter placed in the ultralow position. The study and control groups had similar catheter indwelling times (mean, 8.2 ± 4.1 vs. 8.5 ± 4.0 days, <i>p</i> = 0.687).</p><p><strong>Conclusions: </strong>This is the first report to present a novel position for the placement of umbilical artery catheters. The preliminary findings for the novel ultralow umbilical artery catheter position indicate that it may provide a safety benefit over the conventional umbilical artery catheter position.</p>","PeriodicalId":45612,"journal":{"name":"Journal of Ultrasonography","volume":"24 98","pages":"1-6"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11608066/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15557/jou.2024.0024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Thrombosis is a common complication of umbilical artery catheterization. The purpose of this study was to compare the novel ultralow umbilical artery catheter position (catheter tip at the junction of the umbilical and internal iliac arteries) versus the conventional high umbilical artery catheter position (tip in the aorta, above the diaphragm) for the incidence of thrombosis.

Study design: This study was conducted in a nonacademic, tertiary-referral neonatal center. The insertion and placement of the umbilical artery catheter was performed under continuous ultrasound guidance. Serial ultrasound examinations were performed to identify thrombosis in 38 consecutive newborns with an umbilical artery catheter placed in the novel ultralow position. The control group consisted of 50 infants with an umbilical artery catheter placed in the standard position.

Results: The incidence of thrombosis requiring anticoagulant treatment was 22% in neonates with an umbilical artery catheter in the standard position. No thrombosis was detected in those with an umbilical artery catheter placed in the ultralow position. The study and control groups had similar catheter indwelling times (mean, 8.2 ± 4.1 vs. 8.5 ± 4.0 days, p = 0.687).

Conclusions: This is the first report to present a novel position for the placement of umbilical artery catheters. The preliminary findings for the novel ultralow umbilical artery catheter position indicate that it may provide a safety benefit over the conventional umbilical artery catheter position.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型超低定位脐动脉导管:一项前瞻性先导研究。
目的:血栓形成是脐动脉置管术的常见并发症。本研究的目的是比较新型的超低脐动脉导管位置(导管尖端位于脐动脉和髂内动脉交界处)与传统的高脐动脉导管位置(导管尖端位于主动脉,膈上方)血栓发生率的差异。研究设计:本研究在一个非学术的三级转诊新生儿中心进行。在连续超声引导下进行脐动脉导管的插入和放置。本文对38例新生儿进行连续超声检查,并将脐动脉导管置于新颖的超低位,以确定血栓形成。对照组由50名婴儿组成,在标准位置放置脐动脉导管。结果:在标准体位放置脐动脉导管的新生儿中,血栓形成需要抗凝治疗的发生率为22%。脐动脉导管放置在超低位未发现血栓形成。研究组与对照组留置导管时间相近(平均8.2±4.1天vs. 8.5±4.0天,p = 0.687)。结论:这是首次报道一种新的脐带动脉导管放置位置。初步研究结果表明,这种新型的超低脐动脉导管位置可能比传统的脐动脉导管位置更安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Ultrasonography
Journal of Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
0.00%
发文量
58
审稿时长
20 weeks
期刊最新文献
Agreement between sonographic and pathoanatomic classifications of pediatric urachal remnants. Ultrasound assessment of larynx and trachea in the neonatal period - analysis of correlations and percentile charts. Dynamic ultrasound and three-dimensional reconstruction in the prenatal diagnosis of amniotic band syndrome. Application of data science methods, including machine learning, in the classification of focal lesions in the thyroid gland. Assessment of the usefulness of ultrasound in the diagnosis of skull fractures in children - a five-year institutional experience.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1