Special Forces Medics Ability to Identify Wooden Foreign Bodies by Point-of-Care Ultrasound.

Kyler Osborne, Theodore J McLean, Jason D Heiner, Vincent Ball
{"title":"Special Forces Medics Ability to Identify Wooden Foreign Bodies by Point-of-Care Ultrasound.","authors":"Kyler Osborne, Theodore J McLean, Jason D Heiner, Vincent Ball","doi":"10.55460/WQLG-2AM0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Detection of retained foreign bodies (FB) is a difficult task in both austere environments and emergency departments, particularly when they are radiolucent and not detectable by plain radiographs. Failure to identify and remove them can lead to increased morbidity.</p><p><strong>Objective: </strong>To determine the accuracy of Special Forces (SF) medics in detecting wooden FBs in tissue models, using point-of-care ultrasound.</p><p><strong>Methods: </strong>A prospective, single-blinded, observational study using chicken thigh models was performed. Medics with no prior soft-tissue ultrasound experience received a 1-hour lecture on ultrasound, then scanned 10 tissue models for up to 3 minutes each. Participants were blinded to the models: five were free of FBs and five contained a single wooden FB of varying lengths (1, 2.5, 5, 7.5, or 10mm) at a depth of 5mm.</p><p><strong>Results: </strong>Twenty SF medics performed 200 total scans. For the detection of wooden FBs, sensitivity was 71.8% (95% CI 50.7-85.7) and specificity 82.0% (95% CI 61.1-92.6). The 10-mm FB was identified with 95% accuracy and had an overall sensitivity of 95% (95% CI 76.4-99).</p><p><strong>Conclusions: </strong>SF medics with minimal ultrasound training are capable of accurately identifying soft-tissue wooden FBs with ultrasound. The FB size, orientation, and proximity to fibrous tissues were important factors in accurate identification. SF medics use of ultrasound to aid in the detection of superficial, soft-tissue FBs is an obtainable and valuable skill.</p>","PeriodicalId":53630,"journal":{"name":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55460/WQLG-2AM0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Detection of retained foreign bodies (FB) is a difficult task in both austere environments and emergency departments, particularly when they are radiolucent and not detectable by plain radiographs. Failure to identify and remove them can lead to increased morbidity.

Objective: To determine the accuracy of Special Forces (SF) medics in detecting wooden FBs in tissue models, using point-of-care ultrasound.

Methods: A prospective, single-blinded, observational study using chicken thigh models was performed. Medics with no prior soft-tissue ultrasound experience received a 1-hour lecture on ultrasound, then scanned 10 tissue models for up to 3 minutes each. Participants were blinded to the models: five were free of FBs and five contained a single wooden FB of varying lengths (1, 2.5, 5, 7.5, or 10mm) at a depth of 5mm.

Results: Twenty SF medics performed 200 total scans. For the detection of wooden FBs, sensitivity was 71.8% (95% CI 50.7-85.7) and specificity 82.0% (95% CI 61.1-92.6). The 10-mm FB was identified with 95% accuracy and had an overall sensitivity of 95% (95% CI 76.4-99).

Conclusions: SF medics with minimal ultrasound training are capable of accurately identifying soft-tissue wooden FBs with ultrasound. The FB size, orientation, and proximity to fibrous tissues were important factors in accurate identification. SF medics use of ultrasound to aid in the detection of superficial, soft-tissue FBs is an obtainable and valuable skill.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
91
期刊最新文献
Abdominal Aortic Junctional Tourniquets: Clinically Important Increases in Pressure in Aortic Zone 1 and Zone 3 in a Cadaveric Study Directly Relevant to Combat Medics Treating Non-Compressible Torso Hemorrhage. Chronicity of Posttraumatic Stress Disorder Symptoms Following Traumatic Brain Injury: A Comparison of Special Operators and Conventional Forces. On Saving - The Psychosocial Benefit of Saving Lives in War and Society. Rethinking the Operational Blood Bank Dilemma: Out of the "Box" Blood Storage and Transportation Evaluation. Special Forces Medics Ability to Identify Wooden Foreign Bodies by Point-of-Care Ultrasound.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1