Special Forces Medics Ability to Identify Wooden Foreign Bodies by Point-of-Care Ultrasound.

Kyler Osborne, Theodore J McLean, Jason D Heiner, Vincent Ball
{"title":"Special Forces Medics Ability to Identify Wooden Foreign Bodies by Point-of-Care Ultrasound.","authors":"Kyler Osborne, Theodore J McLean, Jason D Heiner, Vincent Ball","doi":"10.55460/WQLG-2AM0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Detection of retained foreign bodies (FB) is a difficult task in both austere environments and emergency departments, particularly when they are radiolucent and not detectable by plain radiographs. Failure to identify and remove them can lead to increased morbidity.</p><p><strong>Objective: </strong>To determine the accuracy of Special Forces (SF) medics in detecting wooden FBs in tissue models, using point-of-care ultrasound.</p><p><strong>Methods: </strong>A prospective, single-blinded, observational study using chicken thigh models was performed. Medics with no prior soft-tissue ultrasound experience received a 1-hour lecture on ultrasound, then scanned 10 tissue models for up to 3 minutes each. Participants were blinded to the models: five were free of FBs and five contained a single wooden FB of varying lengths (1, 2.5, 5, 7.5, or 10mm) at a depth of 5mm.</p><p><strong>Results: </strong>Twenty SF medics performed 200 total scans. For the detection of wooden FBs, sensitivity was 71.8% (95% CI 50.7-85.7) and specificity 82.0% (95% CI 61.1-92.6). The 10-mm FB was identified with 95% accuracy and had an overall sensitivity of 95% (95% CI 76.4-99).</p><p><strong>Conclusions: </strong>SF medics with minimal ultrasound training are capable of accurately identifying soft-tissue wooden FBs with ultrasound. The FB size, orientation, and proximity to fibrous tissues were important factors in accurate identification. SF medics use of ultrasound to aid in the detection of superficial, soft-tissue FBs is an obtainable and valuable skill.</p>","PeriodicalId":53630,"journal":{"name":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of special operations medicine : a peer reviewed journal for SOF medical professionals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55460/WQLG-2AM0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Detection of retained foreign bodies (FB) is a difficult task in both austere environments and emergency departments, particularly when they are radiolucent and not detectable by plain radiographs. Failure to identify and remove them can lead to increased morbidity.

Objective: To determine the accuracy of Special Forces (SF) medics in detecting wooden FBs in tissue models, using point-of-care ultrasound.

Methods: A prospective, single-blinded, observational study using chicken thigh models was performed. Medics with no prior soft-tissue ultrasound experience received a 1-hour lecture on ultrasound, then scanned 10 tissue models for up to 3 minutes each. Participants were blinded to the models: five were free of FBs and five contained a single wooden FB of varying lengths (1, 2.5, 5, 7.5, or 10mm) at a depth of 5mm.

Results: Twenty SF medics performed 200 total scans. For the detection of wooden FBs, sensitivity was 71.8% (95% CI 50.7-85.7) and specificity 82.0% (95% CI 61.1-92.6). The 10-mm FB was identified with 95% accuracy and had an overall sensitivity of 95% (95% CI 76.4-99).

Conclusions: SF medics with minimal ultrasound training are capable of accurately identifying soft-tissue wooden FBs with ultrasound. The FB size, orientation, and proximity to fibrous tissues were important factors in accurate identification. SF medics use of ultrasound to aid in the detection of superficial, soft-tissue FBs is an obtainable and valuable skill.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
特种部队医务人员通过即时超声识别木质异物的能力。
背景:在恶劣的环境和急诊科中,检测残留的异物(FB)是一项艰巨的任务,特别是当它们是放射性的,而x线平片无法检测到时。不能识别和清除它们会导致发病率增加。目的:确定特种部队(SF)医务人员使用即时超声检测组织模型中木制FBs的准确性。方法:采用鸡腿模型进行前瞻性、单盲、观察性研究。之前没有软组织超声经验的医务人员接受了1小时的超声讲座,然后扫描了10个组织模型,每个模型最长3分钟。参与者对模型不知情:五个没有FB,五个包含一个长度不同的木制FB(1,2.5, 5,7.5或10mm),深度为5mm。结果:20名SF医务人员共进行了200次扫描。对于木质FBs的检测,敏感性为71.8% (95% CI 50.7-85.7),特异性为82.0% (95% CI 61.1-92.6)。10毫米FB的识别准确率为95%,总灵敏度为95% (95% CI为76.4-99)。结论:SF医务人员经过最少的超声训练,能够用超声准确识别软组织木制FBs。FB的大小,取向和接近纤维组织是准确识别的重要因素。SF医生使用超声波来帮助检测浅表软组织FBs是一项可获得且有价值的技能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
91
期刊最新文献
The Use of Different Types of Supraglottic Airway Devices by Medics on a Manikin with Night Vision Goggles: A Pilot Study. Special Operations Forces Lessons Learned: Beirut Blast. Abdominal Aortic Junctional Tourniquets: Clinically Important Increases in Pressure in Aortic Zone 1 and Zone 3 in a Cadaveric Study Directly Relevant to Combat Medics Treating Non-Compressible Torso Hemorrhage. Chronicity of Posttraumatic Stress Disorder Symptoms Following Traumatic Brain Injury: A Comparison of Special Operators and Conventional Forces. On Saving - The Psychosocial Benefit of Saving Lives in War and Society.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1