External Ventricular Drain Misadministration Events: Systematic Literature Review and Report of a Case.

IF 1.7 4区 医学 Q3 CLINICAL NEUROLOGY Operative Neurosurgery Pub Date : 2024-12-03 DOI:10.1227/ons.0000000000001477
Arevik Abramyan, Evgenii Belykh, Patel Ruchi, John Gillick, Ira Goldstein
{"title":"External Ventricular Drain Misadministration Events: Systematic Literature Review and Report of a Case.","authors":"Arevik Abramyan, Evgenii Belykh, Patel Ruchi, John Gillick, Ira Goldstein","doi":"10.1227/ons.0000000000001477","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>External ventricular drain (EVD) is a common neurosurgical procedure with potential complications, including catheter misplacement, infection, mechanical obstruction, and inadvertent catheter pull-out. A less discussed but critical complication is the misadministration of medications into EVD. This project aimed to review the literature on EVD misadministration and discuss preventative measures, emphasizing the new International Organization for Standardization (ISO) standard for neuraxial connectors.</p><p><strong>Methods: </strong>A systematic review of PubMed, Embase, and SCOPUS databases was conducted to identify studies reporting misadministration in EVD systems. We also present a case of misadministration of a blood product into an EVD. Factors contributing to these events were researched, relevant guidelines from professional organizations were reviewed, and preventive strategies, including the novel NRFit® connector designed to prevent such errors, were discussed.</p><p><strong>Results: </strong>The literature review identified 7 reports of 8 cases of misadministration involving substances such as gadolinium-based contrast agents, anesthetic agents, and antiepileptic drugs. In addition, we report a case of an 87-year-old man with multiple traumatic brain injuries, where a blood transfusion line was mistakenly connected to the EVD. This incident is the first reported case of blood misadministration through EVD. Despite immediate drainage and flushing of the EVD system with saline, the patient's condition did not improve, and he eventually died. Contributing factors included unfamiliarity with the EVD system, similarity to IV connectors, and poor visibility during procedures. Importantly, the novel ISO 80369 standard for all neuraxial connectors, including NRFit® connectors that have a 20% smaller nozzle outside diameter than traditional Luer connectors, has been recommended to prevent misconnection errors and mitigate associated risks.</p><p><strong>Conclusion: </strong>Misadministration to EVD connectors is a preventable event that highlights the need for enhanced safety solutions. Adoption of ISO standard neuraxial connectors, thorough training, and the use of distinctly marked equipment are critical steps in minimizing risks.</p>","PeriodicalId":54254,"journal":{"name":"Operative Neurosurgery","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1227/ons.0000000000001477","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: External ventricular drain (EVD) is a common neurosurgical procedure with potential complications, including catheter misplacement, infection, mechanical obstruction, and inadvertent catheter pull-out. A less discussed but critical complication is the misadministration of medications into EVD. This project aimed to review the literature on EVD misadministration and discuss preventative measures, emphasizing the new International Organization for Standardization (ISO) standard for neuraxial connectors.

Methods: A systematic review of PubMed, Embase, and SCOPUS databases was conducted to identify studies reporting misadministration in EVD systems. We also present a case of misadministration of a blood product into an EVD. Factors contributing to these events were researched, relevant guidelines from professional organizations were reviewed, and preventive strategies, including the novel NRFit® connector designed to prevent such errors, were discussed.

Results: The literature review identified 7 reports of 8 cases of misadministration involving substances such as gadolinium-based contrast agents, anesthetic agents, and antiepileptic drugs. In addition, we report a case of an 87-year-old man with multiple traumatic brain injuries, where a blood transfusion line was mistakenly connected to the EVD. This incident is the first reported case of blood misadministration through EVD. Despite immediate drainage and flushing of the EVD system with saline, the patient's condition did not improve, and he eventually died. Contributing factors included unfamiliarity with the EVD system, similarity to IV connectors, and poor visibility during procedures. Importantly, the novel ISO 80369 standard for all neuraxial connectors, including NRFit® connectors that have a 20% smaller nozzle outside diameter than traditional Luer connectors, has been recommended to prevent misconnection errors and mitigate associated risks.

Conclusion: Misadministration to EVD connectors is a preventable event that highlights the need for enhanced safety solutions. Adoption of ISO standard neuraxial connectors, thorough training, and the use of distinctly marked equipment are critical steps in minimizing risks.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
外脑室漏用药不当事件:系统文献回顾及1例报告。
背景和目的:外脑室引流(EVD)是一种常见的神经外科手术,具有潜在的并发症,包括导管错位、感染、机械阻塞和无意拔出导管。一个较少讨论但关键的并发症是对埃博拉病毒病用药不当。本项目旨在回顾有关EVD管理不当的文献,并讨论预防措施,重点介绍新的国际标准化组织(ISO)标准。方法:对PubMed、Embase和SCOPUS数据库进行系统回顾,以确定报告EVD系统用药不当的研究。我们还提出了一个误用血液制品进入埃博拉病毒病的病例。研究了导致这些事件的因素,审查了专业组织的相关指南,并讨论了预防策略,包括旨在防止此类错误的新型NRFit®连接器。结果:通过文献回顾,发现了8例误给药的7例报告,涉及钆基造影剂、麻醉剂和抗癫痫药物等物质。此外,我们报告了一例87岁男性多处创伤性脑损伤病例,其中输血管道错误地连接到EVD。这一事件是报告的首例通过埃博拉病毒病引起的血液管理不当病例。尽管立即用生理盐水引流和冲洗埃博拉病毒病系统,但患者的病情没有改善,最终死亡。影响因素包括对EVD系统的不熟悉,与静脉注射连接器的相似性,以及手术过程中的可视性差。重要的是,所有轴向连接器的新型ISO 80369标准,包括NRFit®连接器,其喷嘴外径比传统的Luer连接器小20%,已被推荐用于防止误连接错误并降低相关风险。结论:EVD连接器给药不当是一种可预防的事件,强调了加强安全解决方案的必要性。采用ISO标准的轴向连接器,彻底的培训,并使用明显标记的设备是最大限度地降低风险的关键步骤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Operative Neurosurgery
Operative Neurosurgery Medicine-Neurology (clinical)
CiteScore
3.10
自引率
13.00%
发文量
530
期刊介绍: Operative Neurosurgery is a bi-monthly, unique publication focusing exclusively on surgical technique and devices, providing practical, skill-enhancing guidance to its readers. Complementing the clinical and research studies published in Neurosurgery, Operative Neurosurgery brings the reader technical material that highlights operative procedures, anatomy, instrumentation, devices, and technology. Operative Neurosurgery is the practical resource for cutting-edge material that brings the surgeon the most up to date literature on operative practice and technique
期刊最新文献
Letter: The Role of Watertight Dural Closure in Supratentorial Craniotomy: A Systematic Review and Meta-Analysis. In Reply: The Role of Watertight Dural Closure in Supratentorial Craniotomy: A Systematic Review and Meta-Analysis. Treatment of Recurrent, Twice Coiled, Previously Ruptured Anterior Inferior Cerebellar Artery-Posterior Inferior Cerebellar Artery Aneurysm With Excision and End-to-End Anastomosis: 2-Dimensional Operative Video. Microsurgical Clip Ligation of a Large Anterior Communicating Artery Aneurysm Previously Treated With Woven Endobridge Device: 2-Dimensional Operative Video. A Cadaveric Feasibility Study of the Biportal Endoscopic Transfrontal Sinus Approach: A Minimally Invasive Approach to the Anterior Cranial Fossa.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1