Coiling of echogenic perineural catheters with integral stylet: A proof-of-concept randomized control trial in a sciatic nerve block simulator and a pilot study in orthopaedic-trauma patients.
Theodosios Saranteas, Eleni Poulogiannopoulou, Maria Riga, Konstantina Panagouli, Andreas Mavrogenis, Thomas Papadimos
{"title":"Coiling of echogenic perineural catheters with integral stylet: A proof-of-concept randomized control trial in a sciatic nerve block simulator and a pilot study in orthopaedic-trauma patients.","authors":"Theodosios Saranteas, Eleni Poulogiannopoulou, Maria Riga, Konstantina Panagouli, Andreas Mavrogenis, Thomas Papadimos","doi":"10.12688/f1000research.155381.2","DOIUrl":null,"url":null,"abstract":"<p><strong>Backround/objectives: </strong>We investigated a technique that facilitates the coiling of a regular straight catheter (with integral stylet) behind the sciatic nerve in an ultrasound (US) regional anaesthesia simulator, and then applied our findings to a series of orthopedic-trauma patients.</p><p><strong>Methods: </strong>We conducted a randomized study of two methods of perineural catheter advancement in a sciatic nerve block Blue Phantom simulator. Two groups of twenty catheters each (method A and method B) were evaluated under real-time ultrasound imaging. The needle in-plane/nerve in-short-axis technique was applied. In method A the catheter was advanced beyond the needle tip with the integral stylet extending along its entire length; in method B the catheter was advanced after its integral stylet was retracted by 6 cm, thus providing flexibility to the catheter's distal end. Additionally, to assess the procedural effectiveness of method B coiling technique, a pilot study was conducted examining 25 perineural catheters coiled underneath the sciatic nerve in trauma-orthopaedic patients to document any catheter tip displacement from their initial position (for 36 hours postoperatively).</p><p><strong>Results: </strong>In the simulation study, method B led to a significantly higher percentage (18/20:90%) of coiled catheters than method A (3/20:15%). Two coiled catheters of method B were found kinked/obstructed. In our patients, after catheter insertion, the distal end of 2/25 (8%) coiled catheters was obstructed. One perineural catheter was dislodged. For the remaining 22 (88%) catheters, ultrasound imaging demonstrated that local anaesthetic infusion made contact with the sciatic nerve, indicating no displacement of the catheter's distal end postoperatively.</p><p><strong>Conclusion: </strong>Regular straight perineural catheters can be coiled if their integral stylet is partially retracted. This coiling method offers extra catheter length adjacent to the nerve structure which potentially mitigates catheter tip displacement.</p><p><strong>Trial registration: </strong>clinicaltrials.gov, registration No: NCT06568510, 23/08/2024, registration URL: https://clinicaltrials.gov/study/NCT06568510?intr=coiling%20of%20echogenic%20sciatic%20nerve&rank=1#study-overview.</p>","PeriodicalId":12260,"journal":{"name":"F1000Research","volume":"13 ","pages":"1103"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11617819/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"F1000Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12688/f1000research.155381.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
引用次数: 0
Abstract
Backround/objectives: We investigated a technique that facilitates the coiling of a regular straight catheter (with integral stylet) behind the sciatic nerve in an ultrasound (US) regional anaesthesia simulator, and then applied our findings to a series of orthopedic-trauma patients.
Methods: We conducted a randomized study of two methods of perineural catheter advancement in a sciatic nerve block Blue Phantom simulator. Two groups of twenty catheters each (method A and method B) were evaluated under real-time ultrasound imaging. The needle in-plane/nerve in-short-axis technique was applied. In method A the catheter was advanced beyond the needle tip with the integral stylet extending along its entire length; in method B the catheter was advanced after its integral stylet was retracted by 6 cm, thus providing flexibility to the catheter's distal end. Additionally, to assess the procedural effectiveness of method B coiling technique, a pilot study was conducted examining 25 perineural catheters coiled underneath the sciatic nerve in trauma-orthopaedic patients to document any catheter tip displacement from their initial position (for 36 hours postoperatively).
Results: In the simulation study, method B led to a significantly higher percentage (18/20:90%) of coiled catheters than method A (3/20:15%). Two coiled catheters of method B were found kinked/obstructed. In our patients, after catheter insertion, the distal end of 2/25 (8%) coiled catheters was obstructed. One perineural catheter was dislodged. For the remaining 22 (88%) catheters, ultrasound imaging demonstrated that local anaesthetic infusion made contact with the sciatic nerve, indicating no displacement of the catheter's distal end postoperatively.
Conclusion: Regular straight perineural catheters can be coiled if their integral stylet is partially retracted. This coiling method offers extra catheter length adjacent to the nerve structure which potentially mitigates catheter tip displacement.
F1000ResearchPharmacology, Toxicology and Pharmaceutics-Pharmacology, Toxicology and Pharmaceutics (all)
CiteScore
5.00
自引率
0.00%
发文量
1646
审稿时长
1 weeks
期刊介绍:
F1000Research publishes articles and other research outputs reporting basic scientific, scholarly, translational and clinical research across the physical and life sciences, engineering, medicine, social sciences and humanities. F1000Research is a scholarly publication platform set up for the scientific, scholarly and medical research community; each article has at least one author who is a qualified researcher, scholar or clinician actively working in their speciality and who has made a key contribution to the article. Articles must be original (not duplications). All research is suitable irrespective of the perceived level of interest or novelty; we welcome confirmatory and negative results, as well as null studies. F1000Research publishes different type of research, including clinical trials, systematic reviews, software tools, method articles, and many others. Reviews and Opinion articles providing a balanced and comprehensive overview of the latest discoveries in a particular field, or presenting a personal perspective on recent developments, are also welcome. See the full list of article types we accept for more information.