Automated Classification of Body MRI Sequences Using Convolutional Neural Networks.

IF 3.8 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Academic Radiology Pub Date : 2024-12-06 DOI:10.1016/j.acra.2024.11.046
Boah Kim, Tejas Sudharshan Mathai, Kimberly Helm, Pritam Mukherjee, Jianfei Liu, Ronald M Summers
{"title":"Automated Classification of Body MRI Sequences Using Convolutional Neural Networks.","authors":"Boah Kim, Tejas Sudharshan Mathai, Kimberly Helm, Pritam Mukherjee, Jianfei Liu, Ronald M Summers","doi":"10.1016/j.acra.2024.11.046","DOIUrl":null,"url":null,"abstract":"<p><strong>Rationale and objectives: </strong>Multi-parametric MRI (mpMRI) studies of the body are routinely acquired in clinical practice. However, a standardized naming convention for MRI protocols and series does not exist currently. Conflicts in the series descriptions present in the DICOM headers arise due to myriad MRI scanners from various manufacturers used for imaging, wide variations in imaging practices across institutions, and technologist preferences. These conflicts affect the hanging protocol, which dictates the arrangement of sequences for the reading radiologist. At present, clinician supervision is necessary to ensure that the correct sequence is being read and used for diagnosis. This pilot work seeks to classify five different series in mpMRI studies acquired at the levels of the chest, abdomen, and pelvis.</p><p><strong>Materials and methods: </strong>First, 2D and 3D classification networks were compared using data acquired by Siemens scanners and the optimal network was identified. Then, its performance was analyzed when trained with different training data quantities. The out-of-distribution (OOD) robustness on data acquired by a Philips scanner was also measured. In addition, the effect of data augmentation on model training was studied. The model was also tested with smaller input volumes through downsampling or cropping. Finally, the model was trained on combined data from both Siemens and Philips scanners to bridge the performance gap between different scanners.</p><p><strong>Results: </strong>Among 2D and 3D networks of ResNet-50, ResNet-101, DenseNet- 121, and EfficientNet-BN0, the 3D DenseNet-121 ensemble achieved an F<sub>1</sub> score of 99.5% when tested on data from the Siemens scanners. The model performed well on OOD data from the Philips scanner and achieved an F<sub>1</sub> score of 86.5%. There was no statistically significant difference between the models trained with and without data augmentation, and between the models trained with original-sized input and with smaller-sized input. When training the model with combined data, the F<sub>1</sub> score improved to 98.8% for the Philips test set and 99.3% for the Siemens test set respectively.</p><p><strong>Conclusion: </strong>Our pilot work is useful for the classification of MRI sequences in studies acquired at the level of the chest, abdomen, and pelvis. It has the potential for robust automation of hanging protocols and the creation of large-scale data cohorts for pre-clinical research.</p>","PeriodicalId":50928,"journal":{"name":"Academic Radiology","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Academic Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.acra.2024.11.046","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Rationale and objectives: Multi-parametric MRI (mpMRI) studies of the body are routinely acquired in clinical practice. However, a standardized naming convention for MRI protocols and series does not exist currently. Conflicts in the series descriptions present in the DICOM headers arise due to myriad MRI scanners from various manufacturers used for imaging, wide variations in imaging practices across institutions, and technologist preferences. These conflicts affect the hanging protocol, which dictates the arrangement of sequences for the reading radiologist. At present, clinician supervision is necessary to ensure that the correct sequence is being read and used for diagnosis. This pilot work seeks to classify five different series in mpMRI studies acquired at the levels of the chest, abdomen, and pelvis.

Materials and methods: First, 2D and 3D classification networks were compared using data acquired by Siemens scanners and the optimal network was identified. Then, its performance was analyzed when trained with different training data quantities. The out-of-distribution (OOD) robustness on data acquired by a Philips scanner was also measured. In addition, the effect of data augmentation on model training was studied. The model was also tested with smaller input volumes through downsampling or cropping. Finally, the model was trained on combined data from both Siemens and Philips scanners to bridge the performance gap between different scanners.

Results: Among 2D and 3D networks of ResNet-50, ResNet-101, DenseNet- 121, and EfficientNet-BN0, the 3D DenseNet-121 ensemble achieved an F1 score of 99.5% when tested on data from the Siemens scanners. The model performed well on OOD data from the Philips scanner and achieved an F1 score of 86.5%. There was no statistically significant difference between the models trained with and without data augmentation, and between the models trained with original-sized input and with smaller-sized input. When training the model with combined data, the F1 score improved to 98.8% for the Philips test set and 99.3% for the Siemens test set respectively.

Conclusion: Our pilot work is useful for the classification of MRI sequences in studies acquired at the level of the chest, abdomen, and pelvis. It has the potential for robust automation of hanging protocols and the creation of large-scale data cohorts for pre-clinical research.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Academic Radiology
Academic Radiology 医学-核医学
CiteScore
7.60
自引率
10.40%
发文量
432
审稿时长
18 days
期刊介绍: Academic Radiology publishes original reports of clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, image-guided interventions and related techniques. It also includes brief technical reports describing original observations, techniques, and instrumental developments; state-of-the-art reports on clinical issues, new technology and other topics of current medical importance; meta-analyses; scientific studies and opinions on radiologic education; and letters to the Editor.
期刊最新文献
Amide proton transfer-weighted (APTw) imaging and derived quantitative metrics in evaluating gliomas: Improved performance compared to magnetization transfer ratio asymmetry (MTRasym). Comparing the Diagnostic Performance of Ultrasound Elastography and Magnetic Resonance Imaging to Differentiate Benign and Malignant Breast Lesions: A Systematic Review and Meta-analysis. CT Multidimensional Radiomics Combined with Inflammatory Immune Score For Preoperative Prediction of Pathological Grade in Esophageal Squamous Cell Carcinoma. Development and Validation of a Predictive Model for Liver Failure After Transarterial Chemoembolization Using Gadoxetic Acid-Enhanced MRI and Functional Liver Imaging Score. Impact of Endorectal Coil Use on Extraprostatic Extension Detection in Prostate MRI: A Retrospective Monocentric Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1