Sana N Buttar, Hasse Møller-Sørensen, Michael Perch, Rene H Petersen, Christian H Møller
{"title":"Feasibility and accuracy of DireCt Lung Ultrasound Evaluation technique to monitor extravascular lung water in porcine lungs.","authors":"Sana N Buttar, Hasse Møller-Sørensen, Michael Perch, Rene H Petersen, Christian H Møller","doi":"10.1093/ejcts/ezae428","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Extravascular lung water precedes deterioration of pulmonary function. Current tools to assess extravascular lung water in a setting of donor lung procurement and ex vivo lung perfusion (EVLP) are either subjective or not feasible. Therefore, a direCt Lung Ultrasound Evaluation (CLUE) has been introduced. This study reassesses the feasibility and accuracy of CLUE by measuring its correlation with lung weight, wet-to-dry ratio (W/D ratio), dynamic compliance and pulmonary vascular resistance (PVR) in a porcine model.</p><p><strong>Methods: </strong>CLUE images, lung weight, dynamic compliance and PVR were recorded and lung samples for W/D ratio were taken before and after EVLP. CLUE score was calculated based on B-lines on images taken at each point of the lung using an established equation.</p><p><strong>Results: </strong>Eighteen porcine lungs were included. Total median of CLUE score, lung weight, W/D ratio and PVR increased significantly, while median of dynamic compliance decreased significantly after EVLP. Total median CLUE score increased significantly in all four surfaces after EVLP with equally high CLUE scores in posterior and diaphragm lines. CLUE score demonstrated a significant strong positive correlation with lung weight (r = 0.825) and W/D ratio (r = 0.837), while CLUE's correlation with dynamic compliance and PVR was significantly moderate to strong (r = -0.669, r = 0.695, respectively).</p><p><strong>Conclusions: </strong>CLUE technique is feasible to assess extravascular lung water in donor lungs after procurement and during EVLP. CLUE score correlated significantly with lung weight, W/D ratio, dynamic compliance and PVR. Transplant suitability of a donor lung may not solely depend on CLUE evaluation.</p>","PeriodicalId":11938,"journal":{"name":"European Journal of Cardio-Thoracic Surgery","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11702978/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Cardio-Thoracic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ejcts/ezae428","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Extravascular lung water precedes deterioration of pulmonary function. Current tools to assess extravascular lung water in a setting of donor lung procurement and ex vivo lung perfusion (EVLP) are either subjective or not feasible. Therefore, a direCt Lung Ultrasound Evaluation (CLUE) has been introduced. This study reassesses the feasibility and accuracy of CLUE by measuring its correlation with lung weight, wet-to-dry ratio (W/D ratio), dynamic compliance and pulmonary vascular resistance (PVR) in a porcine model.
Methods: CLUE images, lung weight, dynamic compliance and PVR were recorded and lung samples for W/D ratio were taken before and after EVLP. CLUE score was calculated based on B-lines on images taken at each point of the lung using an established equation.
Results: Eighteen porcine lungs were included. Total median of CLUE score, lung weight, W/D ratio and PVR increased significantly, while median of dynamic compliance decreased significantly after EVLP. Total median CLUE score increased significantly in all four surfaces after EVLP with equally high CLUE scores in posterior and diaphragm lines. CLUE score demonstrated a significant strong positive correlation with lung weight (r = 0.825) and W/D ratio (r = 0.837), while CLUE's correlation with dynamic compliance and PVR was significantly moderate to strong (r = -0.669, r = 0.695, respectively).
Conclusions: CLUE technique is feasible to assess extravascular lung water in donor lungs after procurement and during EVLP. CLUE score correlated significantly with lung weight, W/D ratio, dynamic compliance and PVR. Transplant suitability of a donor lung may not solely depend on CLUE evaluation.
期刊介绍:
The primary aim of the European Journal of Cardio-Thoracic Surgery is to provide a medium for the publication of high-quality original scientific reports documenting progress in cardiac and thoracic surgery. The journal publishes reports of significant clinical and experimental advances related to surgery of the heart, the great vessels and the chest. The European Journal of Cardio-Thoracic Surgery is an international journal and accepts submissions from all regions. The journal is supported by a number of leading European societies.