Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL Physical and Engineering Sciences in Medicine Pub Date : 2024-12-10 DOI:10.1007/s13246-024-01499-6
Hiroki Kawashima, Katsuhiro Ichikawa, Ryoichi Yoshida, Takuto Katayama, Makoto Arimoto, Jun Kataoka, Hiroji Nagata, Satoshi Kobayashi
{"title":"Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment.","authors":"Hiroki Kawashima, Katsuhiro Ichikawa, Ryoichi Yoshida, Takuto Katayama, Makoto Arimoto, Jun Kataoka, Hiroji Nagata, Satoshi Kobayashi","doi":"10.1007/s13246-024-01499-6","DOIUrl":null,"url":null,"abstract":"<p><p>To confirm the performance improvement of virtual monoenergetic images (VMIs) for iodine contrast tasks in a clinical photon-counting detector CT (PCD CT) using Fourier-based assessment, compared with those in the latest-generation dual-source dual-energy CT (DECT). A water-filled bath with a diameter of 300 mm, which contains rod-shaped phantoms equivalent to diluted iodine (2 and 12 mg/mL), was scanned using PCD CT and DECT at 15, 7.5, and 3 mGy. VMIs were generated without any iterative reconstruction algorithm. Task transfer function (TTF), noise power spectrum (NPS), and slice sensitivity profile were evaluated for VMIs at 70 and 40 keV. The detectability index (d') and the squared system performance function (SPF<sup>2</sup>) calculated by TTF<sup>2</sup>/NPS were compared. At 40 keV, the d' values of PCD CT were higher (percentage increase of 25.7-39.9%) than those of DECT, whereas at 70 keV, the difference was rather small. The SPF<sup>2</sup> values at 40 keV of PCD CT grew notably higher than those of DECT as the spatial frequency increased. The higher SPF<sup>2</sup> values endorsed the lower image noise and the sharper edge of the rod phantom as observed. The d' and SPF<sup>2</sup> in VMIs at 40 keV of PCD CT were notably higher than those of DECT, which endorsed the clinical advantages of PCD CT that had been previously reported in various studies.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2024-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01499-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

To confirm the performance improvement of virtual monoenergetic images (VMIs) for iodine contrast tasks in a clinical photon-counting detector CT (PCD CT) using Fourier-based assessment, compared with those in the latest-generation dual-source dual-energy CT (DECT). A water-filled bath with a diameter of 300 mm, which contains rod-shaped phantoms equivalent to diluted iodine (2 and 12 mg/mL), was scanned using PCD CT and DECT at 15, 7.5, and 3 mGy. VMIs were generated without any iterative reconstruction algorithm. Task transfer function (TTF), noise power spectrum (NPS), and slice sensitivity profile were evaluated for VMIs at 70 and 40 keV. The detectability index (d') and the squared system performance function (SPF2) calculated by TTF2/NPS were compared. At 40 keV, the d' values of PCD CT were higher (percentage increase of 25.7-39.9%) than those of DECT, whereas at 70 keV, the difference was rather small. The SPF2 values at 40 keV of PCD CT grew notably higher than those of DECT as the spatial frequency increased. The higher SPF2 values endorsed the lower image noise and the sharper edge of the rod phantom as observed. The d' and SPF2 in VMIs at 40 keV of PCD CT were notably higher than those of DECT, which endorsed the clinical advantages of PCD CT that had been previously reported in various studies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
期刊最新文献
Use of a virtual phantom to assess the capability of a treatment planning system to perform magnetic resonance image distortion correction. [113mIn]In-RM2: a high potential agent for SPECT imaging of GRPR-expressing tumors. Enhancing percutaneous coronary intervention using TriVOCTNet: a multi-task deep learning model for comprehensive intravascular optical coherence tomography analysis. Memory enhancement by transcranial radiofrequency wave treatment occurs without appreciably increasing brain temperature. SchizoLMNet: a modified lightweight MobileNetV2- architecture for automated schizophrenia detection using EEG-derived spectrograms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1