Comparative evaluation of SanAgileTMSA01 ultrasonic scalpel and Johnson & Johnson GEN11, and HAR36 for efficacy and safety.

Expert review of medical devices Pub Date : 2024-12-01 Epub Date: 2024-12-12 DOI:10.1080/17434440.2024.2440599
Xin Xie, Fanyu Huang, Jun Yao, Shifeng Teng, Yi Gao, Lu Chen, Haofei Wang, Wenbin Rui, Wei He, Le Xu, Hai Huang, Hongchao He, Xiaojing Wang, Fukang Sun, Yu Zhu, Zhiqian Hu, Danfeng Xu
{"title":"Comparative evaluation of SanAgile<sup>TM</sup>SA01 ultrasonic scalpel and Johnson & Johnson GEN11, and HAR36 for efficacy and safety.","authors":"Xin Xie, Fanyu Huang, Jun Yao, Shifeng Teng, Yi Gao, Lu Chen, Haofei Wang, Wenbin Rui, Wei He, Le Xu, Hai Huang, Hongchao He, Xiaojing Wang, Fukang Sun, Yu Zhu, Zhiqian Hu, Danfeng Xu","doi":"10.1080/17434440.2024.2440599","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The advent of ultrasonic scalpels has remarkably advanced minimally invasive surgery; however, the Chinese market's reliance on imports highlights the urgent need for a cost-effective, efficient, and domestically produced surgical scalpel. This study aimed to compare SanAgile<sup>TM</sup>SA01 with the Johnson & Johnson GEN11, and HAR36 surgical devices.</p><p><strong>Research design and methods: </strong>In total, 152 participants requiring urological or general laparoscopic surgery were randomly and equally divided between the two hospitals and randomized to the test and control groups. Clinical outcomes, adverse event rates, intraoperative bleeding, and surgery duration were compared between the two devices.</p><p><strong>Results: </strong>The clinical application rate of both devices was 100%. There were no significant differences between the two groups in intraoperative bleeding, surgery duration, and incidence of adverse events. In the test group, five device-related adverse events occurred (6.58%), compared to two (2.63%) in the control group (no significant difference). The device-related adverse events did not result in any sequelae.</p><p><strong>Conclusions: </strong>The clinical performance of the SanAgile<sup>TM</sup>SA01 was comparable to that of the Johnson & Johnson GEN11 and HAR36. The SanAgile<sup>TM</sup>SA01 device may serve as a viable alternative ultrasonic surgical tool, thereby providing clinicians with additional options.</p><p><strong>Trial registration: </strong>Registration number of Shanghai Medical Equipment Preparation 20,190,114.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":" ","pages":"1211-1217"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2024.2440599","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The advent of ultrasonic scalpels has remarkably advanced minimally invasive surgery; however, the Chinese market's reliance on imports highlights the urgent need for a cost-effective, efficient, and domestically produced surgical scalpel. This study aimed to compare SanAgileTMSA01 with the Johnson & Johnson GEN11, and HAR36 surgical devices.

Research design and methods: In total, 152 participants requiring urological or general laparoscopic surgery were randomly and equally divided between the two hospitals and randomized to the test and control groups. Clinical outcomes, adverse event rates, intraoperative bleeding, and surgery duration were compared between the two devices.

Results: The clinical application rate of both devices was 100%. There were no significant differences between the two groups in intraoperative bleeding, surgery duration, and incidence of adverse events. In the test group, five device-related adverse events occurred (6.58%), compared to two (2.63%) in the control group (no significant difference). The device-related adverse events did not result in any sequelae.

Conclusions: The clinical performance of the SanAgileTMSA01 was comparable to that of the Johnson & Johnson GEN11 and HAR36. The SanAgileTMSA01 device may serve as a viable alternative ultrasonic surgical tool, thereby providing clinicians with additional options.

Trial registration: Registration number of Shanghai Medical Equipment Preparation 20,190,114.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Proactive esophageal cooling during radiofrequency cardiac ablation: data update including applications in very high-power short duration ablation. BComparison of supraglottic airway device vs. endotracheal intubation for initial airway management in out-of-hospital cardiac arrest: a systematic review and meta-analysis. Effects of elevated body mass index on the success of total knee and total hip arthroplasty: a comprehensive overview. Comparison of 6-lead smartphone ECG and 12-lead ECG in athletes and a genetic heart disease population. Modular cardiac rhythm management system and results of MODULAR ATP trial: an era of personalized device medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1