Capnodynamic determination of end-expiratory lung volume in a porcine model of hypoxic pulmonary vasoconstriction.

IF 2 3区 医学 Q2 ANESTHESIOLOGY Journal of Clinical Monitoring and Computing Pub Date : 2024-12-12 DOI:10.1007/s10877-024-01251-1
Aron Törnwall, Mats Wallin, Magnus Hallbäck, Per-Arne Lönnqvist, Jacob Karlsson
{"title":"Capnodynamic determination of end-expiratory lung volume in a porcine model of hypoxic pulmonary vasoconstriction.","authors":"Aron Törnwall, Mats Wallin, Magnus Hallbäck, Per-Arne Lönnqvist, Jacob Karlsson","doi":"10.1007/s10877-024-01251-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The capnodynamic method, End Expiratory Lung Volume CO<sub>2</sub> (EELV-CO<sub>2</sub>), utilizes exhaled carbon dioxide analysis to estimate End-Expiratory Lung Volume (EELV) and has been validated in both normal lungs and lung injury models. Its performance under systemic hypoxia and variations in CO<sub>2</sub> elimination is not examined. This study aims to validate EELV-CO<sub>2</sub> against inert gas wash in/wash out (EELV- SF6, sulfur hexafluoride) in a porcine model of stable hemodynamic conditions followed by hypoxic pulmonary vasoconstriction and inhaled nitric oxide (iNO).</p><p><strong>Methods: </strong>Ten mechanically ventilated piglets were exposed to a hypoxic gas mixture and selective pulmonary vasoconstriction. Inhalation of nitric oxide was used to reverse the pulmonary vasoconstriction. Paired recordings of EELV-CO<sub>2</sub> and EELV-SF6, were conducted to assess their agreement of absolute values.</p><p><strong>Results: </strong>EELV-CO<sub>2</sub> showed a bias of + 5 ml kg<sup>- 1</sup> compared to EELV-SF6, upper limit of agreement of 11 ml kg<sup>- 1</sup> (95%CI: 9-13 ml kg<sup>- 1</sup>), lower limit of agreement - 1 ml kg<sup>- 1</sup> (95%CI: -3- 0 ml kg<sup>- 1</sup>), mean percentage error 34%. Agreement between EELV-CO<sub>2</sub> and EELV-SF6 was largely constant but was affected by progressing hypoxia and reached maximum limit of agreement after iNO exposure. Re-introduction of normoxemia then stabilized bias and limits of agreement to baseline levels.</p><p><strong>Conclusion: </strong>EELV-CO<sub>2</sub> generates absolute values in parallel with EELV -SF6. Stressing EELV-CO<sub>2</sub> with hypoxic pulmonary vasoconstriction and iNO, transiently impairs the agreement which stabilizes once normoxemia is reestablished.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-024-01251-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The capnodynamic method, End Expiratory Lung Volume CO2 (EELV-CO2), utilizes exhaled carbon dioxide analysis to estimate End-Expiratory Lung Volume (EELV) and has been validated in both normal lungs and lung injury models. Its performance under systemic hypoxia and variations in CO2 elimination is not examined. This study aims to validate EELV-CO2 against inert gas wash in/wash out (EELV- SF6, sulfur hexafluoride) in a porcine model of stable hemodynamic conditions followed by hypoxic pulmonary vasoconstriction and inhaled nitric oxide (iNO).

Methods: Ten mechanically ventilated piglets were exposed to a hypoxic gas mixture and selective pulmonary vasoconstriction. Inhalation of nitric oxide was used to reverse the pulmonary vasoconstriction. Paired recordings of EELV-CO2 and EELV-SF6, were conducted to assess their agreement of absolute values.

Results: EELV-CO2 showed a bias of + 5 ml kg- 1 compared to EELV-SF6, upper limit of agreement of 11 ml kg- 1 (95%CI: 9-13 ml kg- 1), lower limit of agreement - 1 ml kg- 1 (95%CI: -3- 0 ml kg- 1), mean percentage error 34%. Agreement between EELV-CO2 and EELV-SF6 was largely constant but was affected by progressing hypoxia and reached maximum limit of agreement after iNO exposure. Re-introduction of normoxemia then stabilized bias and limits of agreement to baseline levels.

Conclusion: EELV-CO2 generates absolute values in parallel with EELV -SF6. Stressing EELV-CO2 with hypoxic pulmonary vasoconstriction and iNO, transiently impairs the agreement which stabilizes once normoxemia is reestablished.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
猪缺氧肺血管收缩模型呼气末肺容量的二氧化碳动力学测定。
目的:二氧化碳动力学方法呼气末肺体积CO2 (EELV-CO2)利用呼出的二氧化碳分析来估计呼气末肺体积(EELV),并已在正常肺和肺损伤模型中得到验证。它在全身缺氧和二氧化碳消除变化下的表现没有被检查。本研究旨在验证EELV- co2在猪模型中对惰性气体洗入/洗出(EELV- SF6,六氟化硫)的抑制作用,该模型具有稳定的血流动力学条件,随后是缺氧肺血管收缩和吸入一氧化氮(iNO)。方法:将10头机械通气仔猪暴露于低氧混合气体和选择性肺血管收缩中。吸入一氧化氮可逆转肺血管收缩。对EELV-CO2和EELV-SF6进行配对记录,以评估其绝对值的一致性。结果:与EELV-SF6相比,EELV-CO2偏差为+ 5 ml kg- 1,一致性上限为11 ml kg- 1 (95%CI: 9-13 ml kg- 1),一致性下限为1 ml kg- 1 (95%CI: 3- 0 ml kg- 1),平均百分比误差为34%。EELV-CO2和EELV-SF6之间的一致性基本不变,但受到进行性缺氧的影响,并在暴露于iNO后达到最大的一致性。重新引入常氧血症后,将偏差稳定下来,并将一致性限制在基线水平。结论:EELV- co2与EELV -SF6平行产生绝对值。应激EELV-CO2与缺氧肺血管收缩和iNO,暂时损害协议,稳定一旦正常氧血症重建。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.30
自引率
13.60%
发文量
144
审稿时长
6-12 weeks
期刊介绍: The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine. The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group. The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.
期刊最新文献
Comment on "Effect of postoperative peripheral nerve blocks on the analgesia nociception index under propofol anesthesia: an observational study." Characterizing drivers of change in intraoperative cerebral saturation using supervised machine learning. Personalized intraoperative arterial pressure management and mitochondrial oxygen tension in patients having major non-cardiac surgery: a pilot substudy of the IMPROVE trial. Virtual reality simulations to alleviate fear and anxiety in children awaiting MRI: a small-scale randomized controlled trial. Is noninvasive hemoglobin measurement suitable for children undergoing preoperative anesthesia consultation?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1