Improved myocardial scar visualization using free-breathing motion-corrected wideband black-blood late gadolinium enhancement imaging in patients with implantable cardiac device.

IF 4.9 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Diagnostic and Interventional Imaging Pub Date : 2024-12-12 DOI:10.1016/j.diii.2024.12.001
Pauline Gut, Hubert Cochet, Panagiotis Antiochos, Guido Caluori, Baptiste Durand, Marion Constantin, Konstantinos Vlachos, Kalvin Narceau, Ambra Masi, Jürg Schwitter, Frederic Sacher, Pierre Jaïs, Matthias Stuber, Aurélien Bustin
{"title":"Improved myocardial scar visualization using free-breathing motion-corrected wideband black-blood late gadolinium enhancement imaging in patients with implantable cardiac device.","authors":"Pauline Gut, Hubert Cochet, Panagiotis Antiochos, Guido Caluori, Baptiste Durand, Marion Constantin, Konstantinos Vlachos, Kalvin Narceau, Ambra Masi, Jürg Schwitter, Frederic Sacher, Pierre Jaïs, Matthias Stuber, Aurélien Bustin","doi":"10.1016/j.diii.2024.12.001","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to introduce and evaluate a novel two-dimensional wideband black-blood (BB) LGE sequence, incorporating wideband inversion recovery, wideband T2 preparation, and non-rigid motion correction (MOCO) reconstruction, to improve myocardial scar detection and address artifacts associated with implantable cardioverter defibrillators (ICDs).</p><p><strong>Materials and methods: </strong>The wideband MOCO free-breathing BB-LGE sequence was tested on a sheep with ischemic scar and in 22 patients with cardiac disease, including 15 with cardiac implants, at 1.5 T. Wideband MOCO free-breathing BB-LGE sequence was compared with conventional and wideband breath-held PSIR-LGE and conventional and wideband breath-held BB-LGE techniques. Image sharpness, entropy, and scar-to-blood, scar-to-myocardium, and blood-to-myocardium contrast were analyzed and reconstruction times were measured. Two expert readers assessed the image quality, ICD artifact severity, and the diagnostic confidence with scar extent. Finally, for the animal study, histopathological assessment of the heart was performed to confirm the presence and localization of scar tissue.</p><p><strong>Results: </strong>In the animal, wideband MOCO free-breathing BB-LGE were reconstructed in 0.6 s and demonstrated a 200 % improvement in scar-to-blood contrast compared to wideband breath-held PSIR-LGE, with significant improvement in image sharpness and reduction in entropy. It also effectively minimized ICD artifacts and accurately detected scars. In patients, wideband MOCO free-breathing BB-LGE were reconstructed in 1.5 ± 0.4 (standard deviation) s per slice. Seventeen patients (17/22; 77 %) with myocardial scars were confidently diagnosed with wideband MOCO free-breathing BB-LGE, compared to 11 (11/22; 50 %) with wideband breath-held PSIR-LGE (P < 0.01).</p><p><strong>Conclusion: </strong>Free-breathing wideband T2-prepared black-blood LGE imaging, combined with motion-corrected reconstruction, offers a promising diagnostic approach for the evaluation of myocardial lesions in patients with ICDs.</p>","PeriodicalId":48656,"journal":{"name":"Diagnostic and Interventional Imaging","volume":" ","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.diii.2024.12.001","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this study was to introduce and evaluate a novel two-dimensional wideband black-blood (BB) LGE sequence, incorporating wideband inversion recovery, wideband T2 preparation, and non-rigid motion correction (MOCO) reconstruction, to improve myocardial scar detection and address artifacts associated with implantable cardioverter defibrillators (ICDs).

Materials and methods: The wideband MOCO free-breathing BB-LGE sequence was tested on a sheep with ischemic scar and in 22 patients with cardiac disease, including 15 with cardiac implants, at 1.5 T. Wideband MOCO free-breathing BB-LGE sequence was compared with conventional and wideband breath-held PSIR-LGE and conventional and wideband breath-held BB-LGE techniques. Image sharpness, entropy, and scar-to-blood, scar-to-myocardium, and blood-to-myocardium contrast were analyzed and reconstruction times were measured. Two expert readers assessed the image quality, ICD artifact severity, and the diagnostic confidence with scar extent. Finally, for the animal study, histopathological assessment of the heart was performed to confirm the presence and localization of scar tissue.

Results: In the animal, wideband MOCO free-breathing BB-LGE were reconstructed in 0.6 s and demonstrated a 200 % improvement in scar-to-blood contrast compared to wideband breath-held PSIR-LGE, with significant improvement in image sharpness and reduction in entropy. It also effectively minimized ICD artifacts and accurately detected scars. In patients, wideband MOCO free-breathing BB-LGE were reconstructed in 1.5 ± 0.4 (standard deviation) s per slice. Seventeen patients (17/22; 77 %) with myocardial scars were confidently diagnosed with wideband MOCO free-breathing BB-LGE, compared to 11 (11/22; 50 %) with wideband breath-held PSIR-LGE (P < 0.01).

Conclusion: Free-breathing wideband T2-prepared black-blood LGE imaging, combined with motion-corrected reconstruction, offers a promising diagnostic approach for the evaluation of myocardial lesions in patients with ICDs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用自由呼吸运动校正宽带黑血后期钆增强成像改善植入式心脏装置患者的心肌瘢痕可视化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diagnostic and Interventional Imaging
Diagnostic and Interventional Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
8.50
自引率
29.10%
发文量
126
审稿时长
11 days
期刊介绍: Diagnostic and Interventional Imaging accepts publications originating from any part of the world based only on their scientific merit. The Journal focuses on illustrated articles with great iconographic topics and aims at aiding sharpening clinical decision-making skills as well as following high research topics. All articles are published in English. Diagnostic and Interventional Imaging publishes editorials, technical notes, letters, original and review articles on abdominal, breast, cancer, cardiac, emergency, forensic medicine, head and neck, musculoskeletal, gastrointestinal, genitourinary, interventional, obstetric, pediatric, thoracic and vascular imaging, neuroradiology, nuclear medicine, as well as contrast material, computer developments, health policies and practice, and medical physics relevant to imaging.
期刊最新文献
Real-time multislice MR-thermometry of the prostate: Assessment of feasibility, accuracy and sources of biases in patients. Node-RADS: Finally, something new on the front of cross-sectional imaging of lymph nodes? Improved myocardial scar visualization using free-breathing motion-corrected wideband black-blood late gadolinium enhancement imaging in patients with implantable cardiac device. Artificial intelligence in emergency neuroradiology: Current applications and perspectives. Breast arterial calcification can be integrated into mammographic reports with minimal effort from radiologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1