{"title":"Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study.","authors":"Hassan Vafapour, Soraya Panah, Payman Rafiepour, Seyedeh Roghayeh Panahi","doi":"10.1093/rpd/ncae221","DOIUrl":null,"url":null,"abstract":"<p><p>Radiation protection in dental radiography can be achieved by adjusting the image field size, exposure, and filtration parameters, and using protective lead shields. The aim of this study is to assess the radiation dose delivered to the thyroid in a phantom irradiated by an orthopantomogram (OPG) system using Geant4 simulation toolkit. Recently, researchers have been trying to find an alternative material to the lead thyroid shield so that the OPG image has minimal metal artifacts. In this study, several materials were introduced as alternatives to lead thyroid shields. The results showed that Pb, Bi, Bi2O3, stainless steel, polyurethane-Bi2O3 (50%-50% mixture), and polyurethane-W (50%-50% mixture) shields provide a thyroid dose reduction of up to 12.0%, 12.3%, 12.0%, 11.6%, 11.8%, and 12.0%, respectively. For the truncated thyroid shields, these values are up to 10.5%, 10.3%, 10.3%, 9.80%, 10.0%, and 10.1%, respectively. Therefore, Bi and Bi2O3 can be suitable alternatives to lead thyroid shields.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae221","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Radiation protection in dental radiography can be achieved by adjusting the image field size, exposure, and filtration parameters, and using protective lead shields. The aim of this study is to assess the radiation dose delivered to the thyroid in a phantom irradiated by an orthopantomogram (OPG) system using Geant4 simulation toolkit. Recently, researchers have been trying to find an alternative material to the lead thyroid shield so that the OPG image has minimal metal artifacts. In this study, several materials were introduced as alternatives to lead thyroid shields. The results showed that Pb, Bi, Bi2O3, stainless steel, polyurethane-Bi2O3 (50%-50% mixture), and polyurethane-W (50%-50% mixture) shields provide a thyroid dose reduction of up to 12.0%, 12.3%, 12.0%, 11.6%, 11.8%, and 12.0%, respectively. For the truncated thyroid shields, these values are up to 10.5%, 10.3%, 10.3%, 9.80%, 10.0%, and 10.1%, respectively. Therefore, Bi and Bi2O3 can be suitable alternatives to lead thyroid shields.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.