Peak Inspiratory Flow Rate as a Prerequisite for Prescription of Inhaler Devices: A Cross-sectional Study.

Spandan Biswas, Jai Kishan Karahyla, Sameer Singhal, Tushar Nehra, Ajit Yadav
{"title":"Peak Inspiratory Flow Rate as a Prerequisite for Prescription of Inhaler Devices: A Cross-sectional Study.","authors":"Spandan Biswas, Jai Kishan Karahyla, Sameer Singhal, Tushar Nehra, Ajit Yadav","doi":"10.59556/japi.72.0741","DOIUrl":null,"url":null,"abstract":"<p><p>Inhaler therapy has become the mainstay of treatment in obstructive airway diseases. Although patients, and to a certain extent doctors also, were not initially comfortable with inhalation devices, they have now become the standard of care in chronic obstructive pulmonary disease (COPD) and asthma. However, the choice of inhaler device prescribed in different subsets of patients is still not clear. Prescription of a device depends upon age, dexterity, hand-mouth coordination, and peak inspiratory flow rates (PIFR). Prescription of wrong inhaler and wrong technique is not uncommon. In our study, 52.6% cases had prescription of wrong inhaler device, as per their PIFR. Physicians often do not consider the PIFR and the respiratory effort of the patient, while advising inhaler device. Only 43% patients with asthma had an adequate asthma control [asthma control test (ACT) > 19]. One of the main causes of a general inability to use an inhaler device properly results from the generation of an inadequate PIFR. It is more pronounced in those using dry powder inhalers (DPI), as it requires a higher effort-dependent inspiratory flow rate. PIFR of patients was divided into four groups, ≤30, 31-60, 61-90, and >90 L/minute. The required PIFR was taken as 30-60 L/minute for metered dose inhaler (MDI) and >60 L/minute for DPI. A positive correlation was noted for PIFR and advice to change the device as per the readings (p = 0.05). A positive correlation was also noted with PIFR compared to smoking/biomass use (p = 0.002). Thus, clinicians should advise inhalers as per PIFR and also continue to monitor PIFR on subsequent visits.</p>","PeriodicalId":22693,"journal":{"name":"The Journal of the Association of Physicians of India","volume":"72 12","pages":"27-29"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Association of Physicians of India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.59556/japi.72.0741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Inhaler therapy has become the mainstay of treatment in obstructive airway diseases. Although patients, and to a certain extent doctors also, were not initially comfortable with inhalation devices, they have now become the standard of care in chronic obstructive pulmonary disease (COPD) and asthma. However, the choice of inhaler device prescribed in different subsets of patients is still not clear. Prescription of a device depends upon age, dexterity, hand-mouth coordination, and peak inspiratory flow rates (PIFR). Prescription of wrong inhaler and wrong technique is not uncommon. In our study, 52.6% cases had prescription of wrong inhaler device, as per their PIFR. Physicians often do not consider the PIFR and the respiratory effort of the patient, while advising inhaler device. Only 43% patients with asthma had an adequate asthma control [asthma control test (ACT) > 19]. One of the main causes of a general inability to use an inhaler device properly results from the generation of an inadequate PIFR. It is more pronounced in those using dry powder inhalers (DPI), as it requires a higher effort-dependent inspiratory flow rate. PIFR of patients was divided into four groups, ≤30, 31-60, 61-90, and >90 L/minute. The required PIFR was taken as 30-60 L/minute for metered dose inhaler (MDI) and >60 L/minute for DPI. A positive correlation was noted for PIFR and advice to change the device as per the readings (p = 0.05). A positive correlation was also noted with PIFR compared to smoking/biomass use (p = 0.002). Thus, clinicians should advise inhalers as per PIFR and also continue to monitor PIFR on subsequent visits.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
509
期刊最新文献
Bilateral Thoracic Herpes Zoster in a 62-year-old Immunocompetent Woman. Comparison of Basal Core Promoter Region Mutation and Precore Mutation among Monoinfected Hepatitis B Virus and Coinfected Hepatitis B Virus with Human Immunodeficiency Virus Patients. Conventional Synthetic Disease-modifying Drugs Remain the Mainstay of Therapy for Rheumatoid Arthritis in India. Current Update on Promising New Anti-Alzheimer's Drugs in Different Phases of Clinical Development: Where Exactly Are We Lacking? Evaluation of Prescription Pattern of Antihypertensives and Its Compliance with Joint National Committee 8 Guidelines in Hospital Setting.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1