Evaluation of Aortic Diseases Using Four-Dimensional Flow Magnetic Resonance Imaging.

IF 0.8 Q4 PERIPHERAL VASCULAR DISEASE Vascular Specialist International Pub Date : 2024-12-18 DOI:10.5758/vsi.240066
Hyun Jung Koo, Hojin Ha, Gyu-Han Lee, Jong En Lee, Sang-Hyub Park, Kyoung-Jin Park, Joon-Won Kang, Dong Hyun Yang
{"title":"Evaluation of Aortic Diseases Using Four-Dimensional Flow Magnetic Resonance Imaging.","authors":"Hyun Jung Koo, Hojin Ha, Gyu-Han Lee, Jong En Lee, Sang-Hyub Park, Kyoung-Jin Park, Joon-Won Kang, Dong Hyun Yang","doi":"10.5758/vsi.240066","DOIUrl":null,"url":null,"abstract":"<p><p>The complex hemodynamic environment within the aortic lumen plays a crucial role in the progression of aortic diseases such as aneurysms and dissections. Traditional imaging modalities often fail to provide comprehensive flow dynamics that are essential for precise risk assessment and timely intervention. The advent of time-resolved, three-dimensional (3D) phase-contrast magnetic resonance imaging (4D flow MRI) has revolutionized the evaluation of aortic diseases by allowing a detailed visualizations of flow patterns and quantification of hemodynamic parameters. This review explores the utility of 4D flow MRI in the assessment of thoracic aortic diseases, highlighting the key hemodynamic parameters, including flow velocity, wall shear stress, oscillatory shear index, relative residence time, vortex, turbulent kinetic energy, flow displacement, pulse wave velocity, aortic distensibility, energy loss, and stasis. We elucidate the significant findings of studies utilizing 4D flow MRI in the context of aortic aneurysms and dissections, highlighting its role in enhancing our understanding of disease mechanisms and improving clinical outcomes. This review underscores the potential of 4D flow MRI to refine risk stratification and guide therapeutic decisions, ultimately contributing to better management of aortic diseases.</p>","PeriodicalId":52311,"journal":{"name":"Vascular Specialist International","volume":"40 ","pages":"41"},"PeriodicalIF":0.8000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular Specialist International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5758/vsi.240066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

The complex hemodynamic environment within the aortic lumen plays a crucial role in the progression of aortic diseases such as aneurysms and dissections. Traditional imaging modalities often fail to provide comprehensive flow dynamics that are essential for precise risk assessment and timely intervention. The advent of time-resolved, three-dimensional (3D) phase-contrast magnetic resonance imaging (4D flow MRI) has revolutionized the evaluation of aortic diseases by allowing a detailed visualizations of flow patterns and quantification of hemodynamic parameters. This review explores the utility of 4D flow MRI in the assessment of thoracic aortic diseases, highlighting the key hemodynamic parameters, including flow velocity, wall shear stress, oscillatory shear index, relative residence time, vortex, turbulent kinetic energy, flow displacement, pulse wave velocity, aortic distensibility, energy loss, and stasis. We elucidate the significant findings of studies utilizing 4D flow MRI in the context of aortic aneurysms and dissections, highlighting its role in enhancing our understanding of disease mechanisms and improving clinical outcomes. This review underscores the potential of 4D flow MRI to refine risk stratification and guide therapeutic decisions, ultimately contributing to better management of aortic diseases.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.10
自引率
11.10%
发文量
29
审稿时长
17 weeks
期刊最新文献
Cyanoacrylate Glue Ablation for Symptomatic Reflux in a Duplicated Femoral Vein: A Case Report. Evaluation of Aortic Diseases Using Four-Dimensional Flow Magnetic Resonance Imaging. Surgical Repair of a Giant Inferior Vena Cava Aneurysm Associated with a Congenital Vascular Anomaly: A Case Report. Duplex Ultrasound of the Femoral Vein for Monitoring Endovascular Treatment of Aortocaval Fistula: A Case Report. Management of Renal Angiomyolipomas in Tuberous Sclerosis: A Case Series.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1