Quantitative Measurement of Multiple Elements in Micro-Quantities of Crude Oil Using In Situ Analysis by Laser Ablation-ICP-MS

IF 2.7 2区 地球科学 Q2 GEOCHEMISTRY & GEOPHYSICS Geostandards and Geoanalytical Research Pub Date : 2024-08-04 DOI:10.1111/ggr.12580
Malika Chbani, Marie-Christine Boiron, Chantal Peiffert, Jérôme Marin, Catherine Lorgeoux, Raymond Michels
{"title":"Quantitative Measurement of Multiple Elements in Micro-Quantities of Crude Oil Using In Situ Analysis by Laser Ablation-ICP-MS","authors":"Malika Chbani,&nbsp;Marie-Christine Boiron,&nbsp;Chantal Peiffert,&nbsp;Jérôme Marin,&nbsp;Catherine Lorgeoux,&nbsp;Raymond Michels","doi":"10.1111/ggr.12580","DOIUrl":null,"url":null,"abstract":"<p>Multi-element quantification in small amounts of material and <i>in situ</i> measurements at the micrometre scale are essential aspects of geological sample investigation. A direct and rapid simultaneous multi-elemental determination of metals in crude oil samples was carried out by combining direct laser ablation of the oil inserted in silica capillaries with inductively coupled plasma-mass spectrometry. The accuracy of LA-ICP-MS determination was demonstrated by analysing CONOSTAN reference material oils, certified for multiple elements, and by comparing LA-ICP-MS measurement results with those obtained by ICP-OES using microwave-assisted sample digestion. The results obtained by both methods were in agreement with certified values. The LA-ICP-MS method showed an adequate precision with a mean relative standard deviation of less than 10% for multi-element determination, and was sufficiently sensitive to determine the majority of elements. LA-ICP-MS was also applied to the determination of elements in crude oils of different origins. LA-ICP-MS is a good alternative method allowing the determination of elements in organic fluids (oil and bitumen) in shorter times, involving less material consumption, smaller test portion size and with higher throughput compared with protocols using, for instance, sample digestion. It validates the possible application of metal analysis in hydrocarbon-containing fluid inclusions for metallogenic purposes.</p>","PeriodicalId":12631,"journal":{"name":"Geostandards and Geoanalytical Research","volume":"48 4","pages":"823-835"},"PeriodicalIF":2.7000,"publicationDate":"2024-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geostandards and Geoanalytical Research","FirstCategoryId":"89","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ggr.12580","RegionNum":2,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Multi-element quantification in small amounts of material and in situ measurements at the micrometre scale are essential aspects of geological sample investigation. A direct and rapid simultaneous multi-elemental determination of metals in crude oil samples was carried out by combining direct laser ablation of the oil inserted in silica capillaries with inductively coupled plasma-mass spectrometry. The accuracy of LA-ICP-MS determination was demonstrated by analysing CONOSTAN reference material oils, certified for multiple elements, and by comparing LA-ICP-MS measurement results with those obtained by ICP-OES using microwave-assisted sample digestion. The results obtained by both methods were in agreement with certified values. The LA-ICP-MS method showed an adequate precision with a mean relative standard deviation of less than 10% for multi-element determination, and was sufficiently sensitive to determine the majority of elements. LA-ICP-MS was also applied to the determination of elements in crude oils of different origins. LA-ICP-MS is a good alternative method allowing the determination of elements in organic fluids (oil and bitumen) in shorter times, involving less material consumption, smaller test portion size and with higher throughput compared with protocols using, for instance, sample digestion. It validates the possible application of metal analysis in hydrocarbon-containing fluid inclusions for metallogenic purposes.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Geostandards and Geoanalytical Research
Geostandards and Geoanalytical Research 地学-地球科学综合
CiteScore
7.10
自引率
18.40%
发文量
54
审稿时长
>12 weeks
期刊介绍: Geostandards & Geoanalytical Research is an international journal dedicated to advancing the science of reference materials, analytical techniques and data quality relevant to the chemical analysis of geological and environmental samples. Papers are accepted for publication following peer review.
期刊最新文献
Issue Information IAG Membership Information Geostandards and Geoanalytical Research GGR Handbook of Rock and Mineral Analysis Chapter 5 The Inductively Coupled Plasma GGR Handbook of Rock and Mineral Analysis [Chapter 13] Laser-Induced Breakdown Spectroscopy (LIBS)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1