Pentaspline catheter or cryoballoon for pulmonary vein plus posterior wall isolation in persistent atrial fibrillation: 1-year outcomes.

IF 5.6 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Heart rhythm Pub Date : 2024-12-16 DOI:10.1016/j.hrthm.2024.12.020
Luigi Pannone, Ioannis Doundoulakis, Domenico Giovanni Della Rocca, Antonio Sorgente, Antonio Bisignani, Giampaolo Vetta, Alvise Del Monte, Giacomo Talevi, Ingrid Overeinder, Gezim Bala, Alexandre Almorad, Erwin Ströker, Juan Sieira, Ali Gharaviri, Mark La Meir, Pedro Brugada, Andrea Sarkozy, Gian Battista Chierchia, Carlo de Asmundis
{"title":"Pentaspline catheter or cryoballoon for pulmonary vein plus posterior wall isolation in persistent atrial fibrillation: 1-year outcomes.","authors":"Luigi Pannone, Ioannis Doundoulakis, Domenico Giovanni Della Rocca, Antonio Sorgente, Antonio Bisignani, Giampaolo Vetta, Alvise Del Monte, Giacomo Talevi, Ingrid Overeinder, Gezim Bala, Alexandre Almorad, Erwin Ströker, Juan Sieira, Ali Gharaviri, Mark La Meir, Pedro Brugada, Andrea Sarkozy, Gian Battista Chierchia, Carlo de Asmundis","doi":"10.1016/j.hrthm.2024.12.020","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Left atrial posterior wall isolation (LAPWI) plus pulmonary vein isolation (PVI) can be performed with either radiofrequency, cryoballoon (CB-A) or, recently, with pulsed field ablation (PFA).</p><p><strong>Objective: </strong>The aim of this study is: (1) to evaluate efficacy and safety of the pentaspline PFA catheter for PVI + LAPWI in patients with persistent AF undergoing an index ablation procedure and (2) to compare 1- year outcomes of PVI + LAPWI with PFA vs CB-A.</p><p><strong>Methods: </strong>All consecutive patients undergoing to an index ablation for persistent atrial fibrillation (AF) at Universitair Ziekenhuis Brussel, Belgium, between 2021 and 2023, were retrospectively screened. Inclusion criteria were: 1) Persistent AF diagnosis following current guidelines; 2) First AF ablation procedure with PVI + LAPWI using the CB-A or the pentaspline PFA catheter; 3) 1-year follow-up completed.</p><p><strong>Results: </strong>A total of 160 patients were included (80 with CB-A and 80 with the pentaspline PFA catheter). PVI + LAPWI was performed with success in 160 (100%) patients and isolation was confirmed at post-procedure high-density mapping in all. Compared with CB-A, PFA was associated with shorter skin-to-skin procedure time, shorter LA dwell time and shorter fluoroscopy time. At survival analysis, freedom from recurrent atrial tachyarrhythmias at 1-year follow-up was similar between CB-A and PFA groups (76.2% vs 78.8%, Log-Rank p=0.63).</p><p><strong>Conclusion: </strong>In patients with persistent AF undergoing an index catheter ablation, the pentaspline PFA catheter is safe and effective for PVI + LAPWI. Outcomes after pentaspline PFA catheter ablation at 1-year are favorable and similar to CB-A catheter.</p>","PeriodicalId":12886,"journal":{"name":"Heart rhythm","volume":" ","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart rhythm","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.hrthm.2024.12.020","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Left atrial posterior wall isolation (LAPWI) plus pulmonary vein isolation (PVI) can be performed with either radiofrequency, cryoballoon (CB-A) or, recently, with pulsed field ablation (PFA).

Objective: The aim of this study is: (1) to evaluate efficacy and safety of the pentaspline PFA catheter for PVI + LAPWI in patients with persistent AF undergoing an index ablation procedure and (2) to compare 1- year outcomes of PVI + LAPWI with PFA vs CB-A.

Methods: All consecutive patients undergoing to an index ablation for persistent atrial fibrillation (AF) at Universitair Ziekenhuis Brussel, Belgium, between 2021 and 2023, were retrospectively screened. Inclusion criteria were: 1) Persistent AF diagnosis following current guidelines; 2) First AF ablation procedure with PVI + LAPWI using the CB-A or the pentaspline PFA catheter; 3) 1-year follow-up completed.

Results: A total of 160 patients were included (80 with CB-A and 80 with the pentaspline PFA catheter). PVI + LAPWI was performed with success in 160 (100%) patients and isolation was confirmed at post-procedure high-density mapping in all. Compared with CB-A, PFA was associated with shorter skin-to-skin procedure time, shorter LA dwell time and shorter fluoroscopy time. At survival analysis, freedom from recurrent atrial tachyarrhythmias at 1-year follow-up was similar between CB-A and PFA groups (76.2% vs 78.8%, Log-Rank p=0.63).

Conclusion: In patients with persistent AF undergoing an index catheter ablation, the pentaspline PFA catheter is safe and effective for PVI + LAPWI. Outcomes after pentaspline PFA catheter ablation at 1-year are favorable and similar to CB-A catheter.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Heart rhythm
Heart rhythm 医学-心血管系统
CiteScore
10.50
自引率
5.50%
发文量
1465
审稿时长
24 days
期刊介绍: HeartRhythm, the official Journal of the Heart Rhythm Society and the Cardiac Electrophysiology Society, is a unique journal for fundamental discovery and clinical applicability. HeartRhythm integrates the entire cardiac electrophysiology (EP) community from basic and clinical academic researchers, private practitioners, engineers, allied professionals, industry, and trainees, all of whom are vital and interdependent members of our EP community. The Heart Rhythm Society is the international leader in science, education, and advocacy for cardiac arrhythmia professionals and patients, and the primary information resource on heart rhythm disorders. Its mission is to improve the care of patients by promoting research, education, and optimal health care policies and standards.
期刊最新文献
Risk factors of late arrhythmia recurrences over 12 months after catheter ablation of atrial fibrillation: Insight into atrial cardiomyopathy. A Novel Focal Lattice Tip Catheter Toggling Between Pulsed Field Energy and Radiofrequency for Atrial Arrhythmia Ablation: Results from a Real-World, Multicenter Registry. Pentaspline catheter or cryoballoon for pulmonary vein plus posterior wall isolation in persistent atrial fibrillation: 1-year outcomes. Prospective Validation of a Pre-Specified Algorithm for the Management of Conduction Disturbances Following Transcatheter Aortic Valve Replacement. The PROMOTE Study. Prediction of Atrial and Ventricular Arrhythmias using Multiple Cardiovascular Risk Factor Polygenic Risk Scores.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1