{"title":"Clinical outcomes of modified left ventricular assist device driveline management.","authors":"Shusuke Imaoka, Noriyuki Kashiyama, Daisuke Yoshioka, Shunsuke Saito, Takuji Kawamura, Ai Kawamura, Ryohei Matsuura, Yusuke Misumi, Koichi Toda, Shigeru Miyagawa","doi":"10.1007/s10047-024-01482-8","DOIUrl":null,"url":null,"abstract":"<p><p>Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site (n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement (n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method (p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01482-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Left ventricular assist devices (LVADs) are implanted in patients with heart failure to support cardiac circulation. However, no standardized methods have been established for LVAD driveline exit site management for the prevention of infections. Therefore, this study evaluated the efficacy of modified driveline management compared with that of conventional driveline management. We retrospectively assessed the outcomes of 262 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2023 at Osaka University in Japan. In conventional driveline management, an LVAD driveline penetrates the skin along the body surface and is fixed near the penetration site (n = 224). In contrast, in our modified fixation method, the LVAD driveline vertically penetrates the skin to prevent ischemia at the driveline exit site and is fixed at a distant abdominal site to prevent the movement of the driveline exit site due to body movement (n = 38). The rates of freedom from LVAD driveline infection in patients with conventional driveline management were 86, 75, and 63% at 1, 2, and 3 years after LVAD implantation, respectively. The rate of freedom from LVAD driveline infection in patients managed by the modified fixation method was 91% at 1, 2, as well as 3 years after LVAD implantation. The freedom rates from LVAD driveline infection in the patients with modified fixation method was lower than in the patients with the conventional method (p = 0.04). Our study revealed that the modified fixation method may offer the possibility for preventing LVAD driveline infection.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.