Design of capacitive electrostatic probes for online measurement of surface charge on ±320 kV tri-post insulators

IF 2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Iet Generation Transmission & Distribution Pub Date : 2024-12-01 DOI:10.1049/gtd2.13326
Jiayi Liu, Xiaoqing Xie, Feng Wang, She Chen, Qiuqin Sun, Lipeng Zhong, Xianhao Fan, Fangwei Liang
{"title":"Design of capacitive electrostatic probes for online measurement of surface charge on ±320 kV tri-post insulators","authors":"Jiayi Liu,&nbsp;Xiaoqing Xie,&nbsp;Feng Wang,&nbsp;She Chen,&nbsp;Qiuqin Sun,&nbsp;Lipeng Zhong,&nbsp;Xianhao Fan,&nbsp;Fangwei Liang","doi":"10.1049/gtd2.13326","DOIUrl":null,"url":null,"abstract":"<p>Compared to offline measurement (interrupting the applied voltage before measurement), online measurement of surface charge on gas-insulated transmission line (GIL) insulators effectively avoids the impact of spontaneous dissipation of charges. Thus, the accuracy of results can be improved. In this article, a measurement model of capacitive electrostatic probes for surface charges on ±320 kV GIL tri-post insulator is established. The geometry of probes is optimized. The feasibility of online measurement of surface charges is analyzed. Results indicate that the surface leakage distance of induced charges is positively related to the length. Furthermore, as the diameter of probes increases, the maximum electric field on the sensitive electrode surface rises, while the radius of the sensitive electrode has the opposite effect. Hence, the diameter of the probe is 6 mm. The length and radius of sensitive electrodes are 50 mm and 1.2 mm, respectively. For online measurement of surface charges on ±320 kV tri-post insulators, the induced potential distribution of the probe is consistent with surface charges. Therefore, the capacitive electrostatic probe in the embedded electrode is appropriate for the online measurement of surface charges on tri-post insulators. It provides a reference for avoiding flashover triggered by surface charge accumulation on DC GIL insulators.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":"18 24","pages":"4034-4041"},"PeriodicalIF":2.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13326","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13326","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Compared to offline measurement (interrupting the applied voltage before measurement), online measurement of surface charge on gas-insulated transmission line (GIL) insulators effectively avoids the impact of spontaneous dissipation of charges. Thus, the accuracy of results can be improved. In this article, a measurement model of capacitive electrostatic probes for surface charges on ±320 kV GIL tri-post insulator is established. The geometry of probes is optimized. The feasibility of online measurement of surface charges is analyzed. Results indicate that the surface leakage distance of induced charges is positively related to the length. Furthermore, as the diameter of probes increases, the maximum electric field on the sensitive electrode surface rises, while the radius of the sensitive electrode has the opposite effect. Hence, the diameter of the probe is 6 mm. The length and radius of sensitive electrodes are 50 mm and 1.2 mm, respectively. For online measurement of surface charges on ±320 kV tri-post insulators, the induced potential distribution of the probe is consistent with surface charges. Therefore, the capacitive electrostatic probe in the embedded electrode is appropriate for the online measurement of surface charges on tri-post insulators. It provides a reference for avoiding flashover triggered by surface charge accumulation on DC GIL insulators.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
±320 kV三柱绝缘子表面电荷在线测量电容式静电探头设计
与离线测量(测量前中断外加电压)相比,气体绝缘输电线路(GIL)绝缘子表面电荷的在线测量可有效避免电荷自发耗散的影响。因此,可以提高测量结果的准确性。本文建立了±320 kV GIL 三柱绝缘子表面电荷的电容静电探头测量模型。对探头的几何形状进行了优化。分析了在线测量表面电荷的可行性。结果表明,感应电荷的表面泄漏距离与长度呈正相关。此外,随着探针直径的增大,敏感电极表面上的最大电场会上升,而敏感电极的半径则会产生相反的影响。因此,探针的直径为 6 毫米。敏感电极的长度和半径分别为 50 毫米和 1.2 毫米。在线测量 ±320 kV 三柱绝缘体的表面电荷时,探针的感应电势分布与表面电荷一致。因此,嵌入式电极中的电容静电探头适用于在线测量三支柱绝缘子的表面电荷。它为避免直流 GIL 绝缘子表面电荷积累引发闪络提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iet Generation Transmission & Distribution
Iet Generation Transmission & Distribution 工程技术-工程:电子与电气
CiteScore
6.10
自引率
12.00%
发文量
301
审稿时长
5.4 months
期刊介绍: IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix. The scope of IET Generation, Transmission & Distribution includes the following: Design of transmission and distribution systems Operation and control of power generation Power system management, planning and economics Power system operation, protection and control Power system measurement and modelling Computer applications and computational intelligence in power flexible AC or DC transmission systems Special Issues. Current Call for papers: Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf
期刊最新文献
Dynamic equivalent modelling for active distributed network considering adjustable loads charging characteristics Enhancing transformer windings monitoring: An approach using longitudinal branch-circuit conductance analysis Dynamic sensitivity-based clustering of distributed energy resources using LoRaWAN technology for voltage regulation in distribution networks A joint data and knowledge-driven method for power system disturbance localisation Assessment of transmission network connection solutions based on HVAC for offshore wind
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1