Fluorescent biosensor for ultra-stability detection of Pax-5a based on a double cascade amplification strategy.

Chang Liu, Xinyi Zhang, Jun Xu, Min Gao, Suqin Wang, Hongbo Li
{"title":"Fluorescent biosensor for ultra-stability detection of Pax-5a based on a double cascade amplification strategy.","authors":"Chang Liu, Xinyi Zhang, Jun Xu, Min Gao, Suqin Wang, Hongbo Li","doi":"10.1016/j.saa.2024.125632","DOIUrl":null,"url":null,"abstract":"<p><p>The development of B-lymphoblastic leukemia is tightly associated with aberrant expression of Pax-5a. This work presented a novel dual signal amplification strategy-based Pax-5a detection method by combining the rolling circle amplification reaction (RCA) and the Entropy-driven toehold-mediated strand displacement (ETSD). Particularly noteworthy is the employed ETSD, which effectively improves the rate and stability of the reaction due to its unique entropy-driven principle. The uniqueness of this method is the combination of two amplification techniques, each utilizing its own strengths to achieve our intended purpose. This sensing method has been effectively used to determine the Pax-5a gene which with a reliable linear correlation for detection within a range and achieving a detection limit of 3.34 pM, calculated using the formula (3σ/S). Furthermore, even in 1 % of human serum samples, the biosensor can identify the target gene with exceptional sensitivity. The recovery rates fall within the range of 96.68-101.76 %, with a relative standard deviation (RSD) of 5.47 %. The method has a strong specificity based on sequence-specific hybridization of nucleic acids, thereby effectively preventing potential false-positive results. This fluorescent biosensor has a high detection capability for Pax-5a, and offers stable results. It provides a new way for early clinical diagnosis of acute lymphoblastic leukemia.</p>","PeriodicalId":94213,"journal":{"name":"Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy","volume":"329 ","pages":"125632"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.saa.2024.125632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The development of B-lymphoblastic leukemia is tightly associated with aberrant expression of Pax-5a. This work presented a novel dual signal amplification strategy-based Pax-5a detection method by combining the rolling circle amplification reaction (RCA) and the Entropy-driven toehold-mediated strand displacement (ETSD). Particularly noteworthy is the employed ETSD, which effectively improves the rate and stability of the reaction due to its unique entropy-driven principle. The uniqueness of this method is the combination of two amplification techniques, each utilizing its own strengths to achieve our intended purpose. This sensing method has been effectively used to determine the Pax-5a gene which with a reliable linear correlation for detection within a range and achieving a detection limit of 3.34 pM, calculated using the formula (3σ/S). Furthermore, even in 1 % of human serum samples, the biosensor can identify the target gene with exceptional sensitivity. The recovery rates fall within the range of 96.68-101.76 %, with a relative standard deviation (RSD) of 5.47 %. The method has a strong specificity based on sequence-specific hybridization of nucleic acids, thereby effectively preventing potential false-positive results. This fluorescent biosensor has a high detection capability for Pax-5a, and offers stable results. It provides a new way for early clinical diagnosis of acute lymphoblastic leukemia.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于双级联扩增策略的Pax-5a超稳定检测荧光生物传感器
b淋巴细胞白血病的发生与Pax-5a的异常表达密切相关。本文提出了一种新的基于双信号放大策略的Pax-5a检测方法,该方法将滚动圈放大反应(RCA)和熵驱动的支点介导的链位移(ETSD)相结合。特别值得注意的是所采用的ETSD,由于其独特的熵驱动原理,有效地提高了反应的速率和稳定性。这种方法的独特之处在于两种放大技术的结合,每一种都利用自己的优势来达到我们预期的目的。该检测方法在一定范围内具有可靠的线性相关性,检测限为3.34 pM,用公式(3σ/S)计算。此外,即使在1%的人类血清样本中,生物传感器也能以异常的灵敏度识别目标基因。加样回收率为96.68 ~ 101.76%,相对标准偏差(RSD)为5.47%。该方法基于核酸序列特异性杂交,具有很强的特异性,可有效防止潜在的假阳性结果。该荧光生物传感器对Pax-5a具有较高的检测能力,检测结果稳定。为急性淋巴细胞白血病的早期临床诊断提供了新的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The impact of halogen substitution quantities on the fluorescence intensity ratio of lanthanide Schiff base complexes. Dual-mode luminescence and colorimetric sensing for Al3+ and Fe2+/Fe3+ ions in water using a zinc coordination polymer. A mitochondrion-targeted poly(N-isopropylacrylamide-coacrylic acid) nanohydrogel with a fluorescent bioprobe for ferrous ion imaging in vitro and in vivo. A paper-based SERS/colorimetry substrate for reliable detection. A portable paper-based surface enhanced Raman scattering platform for Al3+ sensing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1