{"title":"Can we make out the coronal plane corrections of the knee region by studying the screw divergence in tension band plate induced growth modulations?","authors":"Anil Agarwal, Kishmita Sachdeva, Ankitha Kanchinadka Sripathy, Varun Garg","doi":"10.1097/BPB.0000000000001224","DOIUrl":null,"url":null,"abstract":"<p><p>We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs. Additionally, changes in the mechanical lateral distal femoral angle and medial proximal tibial angle were calculated from the follow-up radiographs. The statistical calculations involved correlating the changes in the above-mentioned parameters and the magnitude of correction. The location of the implant was in the distal femur in 49 and the proximal tibia in 19 limbs. A mean correction of 12.1° was achieved at a follow-up of 12.1 months. The correction was calculated as 1.1°/month (SD = 0.6). The correlation of screw divergence (R = -0.01; P = 0.97) and changes in screw trajectory angle (R = -0.11; P = 0.36) to the angular correction achieved was statistically insignificant. The changes in the interscrew angle did not correlate with the angular correction following tension band plates.</p>","PeriodicalId":50092,"journal":{"name":"Journal of Pediatric Orthopaedics-Part B","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics-Part B","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000001224","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs. Additionally, changes in the mechanical lateral distal femoral angle and medial proximal tibial angle were calculated from the follow-up radiographs. The statistical calculations involved correlating the changes in the above-mentioned parameters and the magnitude of correction. The location of the implant was in the distal femur in 49 and the proximal tibia in 19 limbs. A mean correction of 12.1° was achieved at a follow-up of 12.1 months. The correction was calculated as 1.1°/month (SD = 0.6). The correlation of screw divergence (R = -0.01; P = 0.97) and changes in screw trajectory angle (R = -0.11; P = 0.36) to the angular correction achieved was statistically insignificant. The changes in the interscrew angle did not correlate with the angular correction following tension band plates.
期刊介绍:
The journal highlights important recent developments from the world''s leading clinical and research institutions. The journal publishes peer-reviewed papers on the diagnosis and treatment of pediatric orthopedic disorders.
It is the official journal of IFPOS (International Federation of Paediatric Orthopaedic Societies).
Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.