{"title":"Can we make out the coronal plane corrections of the knee region by studying the screw divergence in tension band plate induced growth modulations?","authors":"Anil Agarwal, Kishmita Sachdeva, Ankitha Kanchinadka Sripathy, Varun Garg","doi":"10.1097/BPB.0000000000001224","DOIUrl":null,"url":null,"abstract":"<p><p>We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs. Additionally, changes in the mechanical lateral distal femoral angle and medial proximal tibial angle were calculated from the follow-up radiographs. The statistical calculations involved correlating the changes in the above-mentioned parameters and the magnitude of correction. The location of the implant was in the distal femur in 49 and the proximal tibia in 19 limbs. A mean correction of 12.1° was achieved at a follow-up of 12.1 months. The correction was calculated as 1.1°/month (SD = 0.6). The correlation of screw divergence (R = -0.01; P = 0.97) and changes in screw trajectory angle (R = -0.11; P = 0.36) to the angular correction achieved was statistically insignificant. The changes in the interscrew angle did not correlate with the angular correction following tension band plates.</p>","PeriodicalId":50092,"journal":{"name":"Journal of Pediatric Orthopaedics-Part B","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2024-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics-Part B","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000001224","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs. Additionally, changes in the mechanical lateral distal femoral angle and medial proximal tibial angle were calculated from the follow-up radiographs. The statistical calculations involved correlating the changes in the above-mentioned parameters and the magnitude of correction. The location of the implant was in the distal femur in 49 and the proximal tibia in 19 limbs. A mean correction of 12.1° was achieved at a follow-up of 12.1 months. The correction was calculated as 1.1°/month (SD = 0.6). The correlation of screw divergence (R = -0.01; P = 0.97) and changes in screw trajectory angle (R = -0.11; P = 0.36) to the angular correction achieved was statistically insignificant. The changes in the interscrew angle did not correlate with the angular correction following tension band plates.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
我们能否通过研究张力带钢板诱导的生长调节中的螺钉散度来确定膝关节区域的冠状面修正?
我们研究了螺钉间角(螺钉发散)的变化与张力带钢板用于膝关节外翻畸形的矫正效果之间的关系。回顾性分析了28名儿童68例手术。在初始和随访x线片中测量螺钉间角和螺钉轨迹角。此外,通过随访x线片计算机械外侧股骨远端角和内侧胫骨近端角的变化。统计计算涉及将上述参数的变化与校正幅度联系起来。49例植体位于股骨远端,19例植体位于胫骨近端。随访12.1个月,平均矫正12.1°。校正计算为1.1°/月(SD = 0.6)。旋散度相关性(R = -0.01;P = 0.97)和螺杆轨迹角变化(R = -0.11;P = 0.36)对获得的角度校正的影响在统计学上不显著。螺钉间角的变化与张力带板后的角度校正无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.20
自引率
9.10%
发文量
170
审稿时长
4-8 weeks
期刊介绍: The journal highlights important recent developments from the world''s leading clinical and research institutions. The journal publishes peer-reviewed papers on the diagnosis and treatment of pediatric orthopedic disorders. It is the official journal of IFPOS (International Federation of Paediatric Orthopaedic Societies). Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool. ​
期刊最新文献
Certain fracture patterns in children/adolescents would be better called 'Barton equivalent' fractures. Single versus double percutaneous pinning of pediatric distal radius fractures. Comparison of radiological, clinical, and functional results of Jakob type 2 lateral condyle fractures treated with closed reduction and percutaneous pinning versus open reduction and K-wire fixation. The anterior and medial open approaches yield superior outcomes compared to the lateral and posterior open approaches in supracondylar humerus fractures in children: a systematic review and network meta-analysis. Is there a place for dorsal hemiepiphysiodesis of the first metatarsal in the treatment of pes cavovarus?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1