A Lightweight Method Integrating Keypoint Detection and Perspective Geometry for Substation Safety Distance Monitoring

IF 3.7 2区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Transactions on Power Delivery Pub Date : 2024-12-25 DOI:10.1109/TPWRD.2024.3522808
Hanbo Zheng;Shiqi Xu;Jinheng Li;Fang Gao;Zhimei Cui
{"title":"A Lightweight Method Integrating Keypoint Detection and Perspective Geometry for Substation Safety Distance Monitoring","authors":"Hanbo Zheng;Shiqi Xu;Jinheng Li;Fang Gao;Zhimei Cui","doi":"10.1109/TPWRD.2024.3522808","DOIUrl":null,"url":null,"abstract":"In the high-voltage environment of substations, due to the lack of effective monitoring methods, personnel may fail to maintain a safe distance from the equipment due to subjective factors, leading to electric shock accidents. To more effectively reduce the occurrence of such accidents, this paper proposes a monocular vision-based method for monitoring the safety distance between personnel and live equipment. Firstly, this paper makes lightweight improvements to the YOLOv8 (You Only Look Once) keypoint detection model by introducing the proposed dense feature fusion (DFF) module and adaptive channel cross (ACC) module into the backbone and neck, respectively, and replacing the network's original path aggregation network (PAN) structure with the bi-directional feature pyramid network (BiFPN) structure. Subsequently, based on the principles of camera imaging and perspective geometry, this paper calculates the mapping relationship between two-dimensional pixel coordinates and three-dimensional world coordinates. Finally, based on the detected keypoints and the obtained mapping relationship, the distance between personnel and live equipment is monitored. Experiments conducted in a substation scenario show that the improved keypoint detection model increases AP from 0.718 to 0.771, reduces parameters from 3.09M to 2.10M, and lowers FLOPs from 8.48G to 7.01G, and the maximum distance measurement error is only 3.778%.","PeriodicalId":13498,"journal":{"name":"IEEE Transactions on Power Delivery","volume":"40 2","pages":"810-821"},"PeriodicalIF":3.7000,"publicationDate":"2024-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Delivery","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10816303/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In the high-voltage environment of substations, due to the lack of effective monitoring methods, personnel may fail to maintain a safe distance from the equipment due to subjective factors, leading to electric shock accidents. To more effectively reduce the occurrence of such accidents, this paper proposes a monocular vision-based method for monitoring the safety distance between personnel and live equipment. Firstly, this paper makes lightweight improvements to the YOLOv8 (You Only Look Once) keypoint detection model by introducing the proposed dense feature fusion (DFF) module and adaptive channel cross (ACC) module into the backbone and neck, respectively, and replacing the network's original path aggregation network (PAN) structure with the bi-directional feature pyramid network (BiFPN) structure. Subsequently, based on the principles of camera imaging and perspective geometry, this paper calculates the mapping relationship between two-dimensional pixel coordinates and three-dimensional world coordinates. Finally, based on the detected keypoints and the obtained mapping relationship, the distance between personnel and live equipment is monitored. Experiments conducted in a substation scenario show that the improved keypoint detection model increases AP from 0.718 to 0.771, reduces parameters from 3.09M to 2.10M, and lowers FLOPs from 8.48G to 7.01G, and the maximum distance measurement error is only 3.778%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种集成关键点检测和透视几何的变电站安全距离监测轻量化方法
在变电站的高压环境中,由于缺乏有效的监控手段,人员可能由于主观因素而无法与设备保持安全距离,从而导致触电事故的发生。为了更有效地减少此类事故的发生,本文提出了一种基于单目视觉的人员与带电设备安全距离监测方法。首先,本文对YOLOv8 (You Only Look Once)关键点检测模型进行轻量级改进,在主干和颈部分别引入本文提出的密集特征融合(DFF)模块和自适应通道交叉(ACC)模块,并用双向特征金字塔网络(BiFPN)结构取代网络原有的路径聚合网络(PAN)结构。随后,根据相机成像和透视几何原理,计算二维像素坐标与三维世界坐标的映射关系。最后,根据检测到的关键点和得到的映射关系,对人员与带电设备之间的距离进行监控。变电站场景实验表明,改进的关键点检测模型将AP从0.718提高到0.771,将参数从3.09M降低到2.1 m,将FLOPs从8.48G降低到7.01G,最大距离测量误差仅为3.778%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Power Delivery
IEEE Transactions on Power Delivery 工程技术-工程:电子与电气
CiteScore
9.00
自引率
13.60%
发文量
513
审稿时长
6 months
期刊介绍: The scope of the Society embraces planning, research, development, design, application, construction, installation and operation of apparatus, equipment, structures, materials and systems for the safe, reliable and economic generation, transmission, distribution, conversion, measurement and control of electric energy. It includes the developing of engineering standards, the providing of information and instruction to the public and to legislators, as well as technical scientific, literary, educational and other activities that contribute to the electric power discipline or utilize the techniques or products within this discipline.
期刊最新文献
Four-Leg Voltage Source Converter With Independent Phase Control for Ground Fault Compensation Dual Grid-Forming MMC With Embedded Storage for Damping Provision Cable Shield Grounding for Transient Overvoltage Testing in Power Generation/Transformer Substations Real-Time Energy Management for Urban Rail Transit With Reversible Substations Based on Deep Reinforcement Learning Transient Model of Grounding System Considering Soil Ionization and Frequency-Dependent Electrical Parameters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1