Development of a novel digestion method utilizing a new PTFE digestor for the rapid and reliable determination of technology-critical elements (TCEs) in granite samples by ICP-OES: A simple approach for the analysis of complex geological matrices.

IF 5.6 1区 化学 Q1 CHEMISTRY, ANALYTICAL Talanta Pub Date : 2025-04-01 Epub Date: 2024-12-20 DOI:10.1016/j.talanta.2024.127426
Venkata Balarama Krishna Mullapudi, Chandrasekaran Krishnan, Venkateswarlu Gumma
{"title":"Development of a novel digestion method utilizing a new PTFE digestor for the rapid and reliable determination of technology-critical elements (TCEs) in granite samples by ICP-OES: A simple approach for the analysis of complex geological matrices.","authors":"Venkata Balarama Krishna Mullapudi, Chandrasekaran Krishnan, Venkateswarlu Gumma","doi":"10.1016/j.talanta.2024.127426","DOIUrl":null,"url":null,"abstract":"<p><p>A new and high performance polytetrafluoroethylene (PTFE) digestor was designed and fabricated in-house for the total dissolution of granite samples for the determination of technology-critical elements (TCEs) by inductively coupled plasma optical emission spectrometry (ICP-OES). Initially, the granite sample (∼0.25 g) was placed in the PTFE digestor and added 8 mL(v/v) of 20%HF+40%HCl+10%HNO<sub>3</sub> acid mixture. After closing, the digestor was directly heated on a hotplate at ∼250 °C for about 2 h (hotplate digestion step (HDS)). Subsequently, the sample mixture was transferred to a graphite-bottom Teflon beaker for evaporation step (ES) at ∼180 °C to remove silica matrix followed by aqua regia treatment step (ATS) to the sample residue for the transformation of highly insoluble metal-fluoro complexes in to soluble chloro-complexes. After ATS, the sample residue was reconstituted in 3 mL of 60 % (v/v) aqua regia. The final sample digests were very clear and stable with no apparently visible fluoride precipitates indicating complete decomposition of different phases present in the granite matrix. The clear sample digests were analysed for REEs (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb, Sc and Y), high field strength elements HFSEs (Ta, Ti, Zr, Nb, Hf and Th) by ICP-OES. The key parameters of the proposed digestion protocol were optimized for achieving quantitative recovery (>95 %). The proposed procedure was validated using granite based reference materials viz., NCSDC-73376, SARM-1 and JG-2. Various novelty aspects are involved in the present work which include (a) utilization of in-house PTFE digestor (b) hotplate heating with dilute acid mixtures (c) complete elimination of metal-fluoride precipitates (d) no need of expensive commercial bomb digestion systems and (e) total dissolution of granite sample for the determination of elements of highly technological relevance in ∼3 h which is much faster than what is achievable using prevailing conventional methods.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"285 ","pages":"127426"},"PeriodicalIF":5.6000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.127426","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A new and high performance polytetrafluoroethylene (PTFE) digestor was designed and fabricated in-house for the total dissolution of granite samples for the determination of technology-critical elements (TCEs) by inductively coupled plasma optical emission spectrometry (ICP-OES). Initially, the granite sample (∼0.25 g) was placed in the PTFE digestor and added 8 mL(v/v) of 20%HF+40%HCl+10%HNO3 acid mixture. After closing, the digestor was directly heated on a hotplate at ∼250 °C for about 2 h (hotplate digestion step (HDS)). Subsequently, the sample mixture was transferred to a graphite-bottom Teflon beaker for evaporation step (ES) at ∼180 °C to remove silica matrix followed by aqua regia treatment step (ATS) to the sample residue for the transformation of highly insoluble metal-fluoro complexes in to soluble chloro-complexes. After ATS, the sample residue was reconstituted in 3 mL of 60 % (v/v) aqua regia. The final sample digests were very clear and stable with no apparently visible fluoride precipitates indicating complete decomposition of different phases present in the granite matrix. The clear sample digests were analysed for REEs (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb, Sc and Y), high field strength elements HFSEs (Ta, Ti, Zr, Nb, Hf and Th) by ICP-OES. The key parameters of the proposed digestion protocol were optimized for achieving quantitative recovery (>95 %). The proposed procedure was validated using granite based reference materials viz., NCSDC-73376, SARM-1 and JG-2. Various novelty aspects are involved in the present work which include (a) utilization of in-house PTFE digestor (b) hotplate heating with dilute acid mixtures (c) complete elimination of metal-fluoride precipitates (d) no need of expensive commercial bomb digestion systems and (e) total dissolution of granite sample for the determination of elements of highly technological relevance in ∼3 h which is much faster than what is achievable using prevailing conventional methods.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用新型聚四氟乙烯消化器开发一种新型消化方法,用于ICP-OES快速可靠地测定花岗岩样品中的技术关键元素(TCEs):一种用于分析复杂地质基质的简单方法。
采用电感耦合等离子体发射光谱法(ICP-OES)测定花岗岩样品中的技术关键元素(TCEs),自制了一种新型高性能聚四氟乙烯(PTFE)消解池。最初,将花岗岩样品(~ 0.25 g)放置在聚四氟乙烯沼气池中,并加入8ml (v/v)的20%HF+40%HCl+10%HNO3酸混合物。关闭后,直接在热板上加热~ 250°C约2小时(热板消化步骤(HDS))。随后,将样品混合物转移到石墨底聚四氟乙烯烧杯中,在~ 180°C下进行蒸发步骤(ES)以去除二氧化硅基质,然后对样品残留物进行王水处理步骤(ATS),将高度不溶的金属-氟配合物转化为可溶的氯配合物。ATS后,样品残渣在3ml 60% (v/v)王水中重组。最终样品消化非常清晰和稳定,没有明显可见的氟化物沉淀,表明花岗岩基质中存在的不同相完全分解。用ICP-OES分析样品中稀土元素(La、Ce、Pr、Nd、Sm、Eu、Gd、Tb、Dy、Ho、Er、Yb、Sc和Y)和高场强元素(Ta、Ti、Zr、Nb、Hf和Th)的含量。对所提出的溶出方案的关键参数进行了优化,以达到定量回收率(> 95%)。采用花岗岩基准材料NCSDC-73376、SARM-1和JG-2验证了所提出的程序。目前的工作涉及到各种新奇的方面,包括(a)利用内部聚四氟乙烯消化器(b)用稀酸混合物热板加热(c)完全消除金属氟化物沉淀(d)不需要昂贵的商业炸弹消化系统和(e)花岗岩样品的完全溶解,用于在~ 3小时内测定具有高度技术相关性的元素,这比使用流行的传统方法要快得多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
期刊最新文献
Corrigendum to 'A novel four-modal nano-sensor based on two-dimensional Mxenes and fully connected artificial neural networks for the highly sensitive and rapid detection of ochratoxin A' [Talanta 283 (2025) 127157]. Detection of uranyl ions by single-hairpin based self-hybridization chain reaction. Dual-signal, one-step simultaneous monitoring of genetic mutation in multiple gene regions using Fe3O4@Au and MOF. A luminescent lanthanide functionalized hydrogen-bonded organic framework hydrogel: Fluorescence sensing platform for copper and iron ions detection. A new near-infrared fluorescence probe for highly selective and sensitive detection and imaging of Butyrylcholinesterase in Alzheimer's disease mice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1